z/VSE V5.1 | z/VSE V4.3 | Unsupported releases
Last update: November 3, 2011
APAR
Date |
PTF |
Contents |
PM50997
2011/11/02 |
UK73224-01C |
DTRIATTN HANGS IN CERTAIN CASES
If in certain cases like heavy loaded system running DTRIATTN in a low priority partition, the SVC 30 gets a busy condition, the subsequent wait may wait forever due to the fact the ECB is already posted. |
PM40434
2011/07/11 |
UK69457-01C |
IND$FILE TRANSFER WITH DBCS TERMINAL DOES NOT ALLOW OPTIONS LRECL=80 BINARY TRANSFERRING TO A VSE LIBRARY
SEND PTFFILE.BIN A:PTFFILE Z (FILE=LIB L=PRD1 S=BASED LRECL=80 BINARY gets message INW0006I BINARY is INVALID or CONFLICTING OPTION if send command is issued by a DBCS terminal. This works on a single byte mode terminal. DBCS uses APVUfile instead of IND$FILE |
PM33126
2011/02/14 |
UK65063-01C |
MESSAGE INDICATOR BLINKING AND NOT RESET AFTER REDISPLAY
If only a few lines left on the screen, entering a command like MAP followed by PF7 and then PF3 end in the fact that the MESSAGE indicator is blinking and cannot be reset. Only ending the console (PF3) resets the console correctly. |
PM32578
2011/02/14 |
UK64714-01C |
UPPERCASE TRANSLATION FOR SPECIAL CHARACTERS 'BA'X AND 'BB'X NOT DISPLAYABLE.
Special characters 'BA'x and 'BB'x cannot be displayed on Japanese terminal. Uppercase translation should reflect this to characters and translate to '4D'x resp. '5D'x. |
PM31473
2011/01/31 |
UK64451-01C |
HANG ON SYSTEM CONSOLE FOLLOWED BY INTERVENTION REQUIRED.
System console got suspended ending up in a hang. Console was an OSA-ICC console. The hang is pointing to IJBCNSTD using MVS simulated TTIMER instead of the DOS TTIMER. |
PM30460
2011/01/20 |
UK63952-01C |
UPPERCASE TRANSLATION OT OME MESSAGES WITH DBCS MESSAGES NOT WORKING CORRECTLY
If default is changed to uppercase in IJBJDEF or IESJDEF, message explanation (PF9) shows garbage. |
PM30311
2011/01/20 |
UK63859-01C |
IESWAITR FAILS IF SEVERAL OUTSTANDING REPLIES ARE THERE FOR 10 OTHER PARTITIONS
IESWAITR fails if there are several outstanding replies for other partitions, such that the target replid has folded onto the nextline of the console response like
AR 0015 1I87I REPLY TO: F6-0006 F8-0008 FA-0010 F9-0009 F7-0007
F3-0003 FB-0118
Reply for FB is not recognized, IESWAITR reissues MSG FB until allowed maximum time is exceeded. |
PM23764
2010/10/04 |
UK60989-01C |
ADJUST COMPILE SKELETONS FOR RPG II ON CICS TS
After PM23298, compile dialogs will use new JCL for RPG II. New parameter for RPGIAUTO program and new stub required for running RPG II compile job with new support. |
PM22283
2010/10/04 |
UK60725-01C |
MESSAGE EXPLANATION FOR JAPANESE TRANSLATED TO UPPERCASE
Message explanation (PF9) is translated to uppercase if the default in IESJDEF is changed to UPPERCASE. The Kanji DBCS characters should not be translated. |
PM23298
2010/09/30 |
UK60877-01C |
IUI SUPPORT FOR RUNNING RPG ON CICS TS
With RPG APARs PM16528 and PM22788, RPG II can be used on CICS TS. With this APAR skeletons RPGINST and RPGSAMPL are established to allow to run RPG without having CICS/VSE installed. |
PM13810
2010/05/26 |
UK57234-01C |
REMOVE OF GENERATION PART NOT DONE IF IF SWITCH BACK TO PRODUCTION USER IS SELECTED IN FSU
Step DTRFSU16 ends with
// EXEC MSHP
1S54I PHASE MSHP IS TO BE FETCHED FROM IJSYSRS.SYSLIB
1S55I LAST RETURN CODE WAS 0016
This is because the MSHP step has no control statements generated. This is in case the generation part should be removed. |
PM05296
2010/02/02 |
UK53789-01C |
GENERATION FEATURE COMPONENT RECORD NOT DELETED FROM HISTORY FILE DURING FSU VERSION UPGRADE
When running a FSU Release/Version upgrade and the Generation Feature is installed, then the PRODUCT-ID is deleted from the history file but not the Component-ID, which should be deleted as well. Without deletion of the Component-ID old PTF or APAR records will be kept in the History file and this may confuse users. |
PM06381
2010/02/01 |
UK53974-01C |
PROGRAM CHECK PROTECTION EXCEPTION IN IESVRCAT IF CATALOG HAS MORE THAN 123 VOLUMES.
If a catalog has more than 123 volumes, fastpath 22 abends with
K402I CSECT ENTERED = IESAVRCAT
K403I ICCF RETURN CODE = 08
This is due to a program check protection exception. |
PM05770
2010/01/28 |
UK53903-01D
UK53905-01E |
ENHANCEMENTS NLS
- VSAM Snap IUI job (Invalid job created by dialog)
- Intolerable PWD in "MAINTAIN USER PROFILES" panel
- PROGRAMMER-ID separates titles and its values in the user profiles report (IESXSUSP in ICCF library 59)
- =3724 IUI (Backup ICCF Library on Tape) ignores the parameter "LABEL PROCESS" on the panel
- IESUPDCF - the difference in behaviour for parameters between real utlity execution and the manual content a little.
- Within report IESTBGRP from =282(IUI) the last USERID names are truncated at the line end
|
PM05277
2010/01/28 |
UK53901-01C |
ENHANCEMENTS NLS
- VSAM Snap IUI job (Invalid job created by dialog)
- Intolerable PWD in "MAINTAIN USER PROFILES" panel
- PROGRAMMER-ID separates titles and its values in the user profiles report (IESXSUSP in ICCF library 59)
- =3724 IUI (Backup ICCF Library on Tape) ignores the parameter "LABEL PROCESS" on the panel
- IESUPDCF - the difference in behaviour for parameters between real utlity execution and the manual content a little.
- Within report IESTBGRP from =282(IUI) the last USERID names are truncated at the line end
|
PK93687
2009/08/12 |
UK49079-01C |
FSU STAGE 2, JOB DTRFSUCL FAILS IN CASE AN ESM IS USED.
Job DTRFSUCL get a return code 16 in case an ESM is used instead of BSM. Conditional JCL should handle this. |
PK92846
2009/08/12 |
UK49061-01C |
ABEND ATNI AND IN CASE THE TCTE INDICATES A SESSION ERROR, OLPD SHOULD NOT BE DRIVEN
After an abend ATNI as well as in case TCTEASE and TCTEUFRI are set, OLPD user screen should not be displayed since the terminal is not available. After a session error OLPD ended in an additional ATCV abend. This abend should be avoided. |
PK87299
2009/06/19 |
UK47529-01C |
PRINT FUNCTION ON PANEL IESADMBSLG DOES NOT WORK ID PROGRAM AUTO INSTALL IS NOT ACTIVE.
No report is generated if program IESCXCT2 is not defined to CICS. Program definition is missing in IUI setup. Define program using CEDA with following values:
Define Program(IESXCT2) Group(VSESPG) Language(ASSEMBLER) Reload(NO) Resident(NO) Executionset(FULLAPI) Description(IESXCT2 - BSM Format Exit) Libdef DUMP in SKJCL0. |
PK86720
2009/05/26 |
UK46803-01C |
WRONG CREATION DATE SHOWN IN VSAM DIALOG.
The panel IESFILDETD on vse/iui shows wrong century in four digits for the year of CREATION DATE, such as 2086261 appeared. Since his problem VSAM file was actually created on 1986 (not on 2086) the CREATION DATE should be shown as 1986261. |
PK85690
2009/04/05 |
UK46117-01C |
DEFAULT LIMIT FOR SORTED POWER ENTRIES BY TIME IS SET TO 99. THIS IS TOO LOW.
The default of 99 entries is too low. Default value should be increased to 999. |
PK81238
2009/03/26 |
UK45222-01C |
CONTROL STARTUP SEQUENCE FOR DMF JOB USING IESWAITR
- Allow IESWAITR serialize startup of DMF partition.
- Downlevel check during FSU release upgrade if generation feature is installed. Gen feature should be removed before Maclib is installed.
- For FCT security allow GROUP01 to access BSTCNTL. Otherwise and authorization check occurs during shuton of CICS.
- VSAM SNAP job STDLABEL parameter not placed correctly.
|
PK78886
2009/01/23 |
UK43373-01C |
AICA ABEND FOR IESZATDX LOOP AFTER ITEMERR CONDITION
Loop after an ITEMERR condition after PUTQ request for queue IEZATDNM. The loop ends in an AICA abend. |
PK77836
2009/01/13 |
UK43049-01E |
APPLICATION IESJNET DOES NOT EXIST. INVALID SELECTION PANEL
When selecting "9 Transfer Files and Jobs to Another System", selection panel IESJNET does not exist. |
PK75318
2008/11/28 |
UK41899-01C |
HARDWAIT FFF STARTING A DYNAMIC PARTITION WITH SAMPLE JOB ACCOUNTING SKJOBACC ACTIVE
- Starting a dynamic partition with job exit SKJOBACC active may result in a hardwait FFF or FED.
- DELBD274 deleted during FSU release/version upgrade.
- Typos in DELOS390, wrong product/component for z/VSE 3.1
- If in panel IESADMBSLG (fastpath 282) option 5 (=delete) was specified, sometimes the group was deleted and no 'confirm delete' message was displayed.
|
PK71654
2008/10/17 |
UK39957-01C |
MISCELLANEOUS FIXES FOR Z/VSE 4.2.0 VSE/IUI |
| Comp. ID |
CLC |
Description |
| 5686-CF8-01 |
01C |
VSE/SP Unique Code |
| 5686-CF8-02 |
01E |
z/VSE MRI Japanese |
| 5686-CF8-02 |
01D |
z/VSE MRI English |
| 5686-CF8-10 |
01C |
VSE/ICCF |
|
Last update: May 23, 2011
APAR
Date |
PTF |
Contents |
PM34712
2011/03/15 |
UK65769-09C |
MESSAGE INDICATOR BLINKING AND NOT RESET AFTER REDISPLAY
If only a few lines left on the screen, entering a command like MAP followed by PF7 and then PF3 end in the fact that the MESSAGE indicator is blinking and cannot be reset. Only ending the console (PF3) resets the console correctly. |
PM33536
2011/03/01 |
UK65156-09C |
UPPERCASE TRANSLATION FOR SPECIAL CHARACTERS 'BA'X AND 'BB'X NOT DISPLAYABLE.
Special characters 'BA'x and 'BB'x cannot be displayed on Japanese terminal. Uppercase translation should reflect this to characters and translate to '4D'x resp. '5D'x. |
PM30528
2011/01/11 |
UK63975-91C |
UPPERCASE TRANSLATION OT OME MESSAGES WITH DBCS MESSAGES NOT WORKING CORRECTLY
If default is changed to uppercase in IJBJDEF or IESJDEF, message explanation (PF9) shows garbage. |
PM23716
2010/10/04 |
UK60949-91C |
ADJUST COMPILE SKELETONS FOR RPG II ON CICS TS
After PM23266, compile dialogs will use new JCL for RPG II. New parameter for RPGIAUTO program and new stub required for running RPG II compile job with new support. |
PM23266
2010/09/30 |
UK60749-91C |
IUI SUPPORT FOR RUNNING RPG ON CICS TS
With RPG APARs PM16528 and PM22788, RPG II can be used on CICS TS. With this APAR skeletons RPGINST and RPGSAMPL are established to allow to run RPG without having CICS/VSE installed. |
PM06335
2010/02/02 |
UK53953-91C |
PROGRAM CHECK PROTECTION EXCEPTION IN IESVRCAT IF CATALOG HAS MORE THAN 123 VOLUMES.
If a catalog has more than 123 volumes, fastpath 22 abends with
K402I CSECT ENTERED = IESAVRCAT
K403I ICCF RETURN CODE = 08
This is due to a program check protection exception. |
PK92982
2009/08/12 |
UK49062-91C |
FSU STAGE 2, JOB DTRFSUCL FAILS IN CASE AN ESM IS USED.
Job DTRFSUCL gets a return code 16 in case an ESM is used instead of BSM. Conditional JCL should handle this. |
PK87494
2009/07/31 |
UK48881-91C |
ABEND ATNI AND IN CASE THE TCTE INDICATES A SESSION ERROR, OLPD SHOULD NOT BE DRIVEN
After an abend ATNI as well as in case TCTEASE and TCTEUFRI are set, OLPD user screen should not be displayed since the terminal is not available. Do not handle ATCV abends and ATND. In case of a session error (TCTEINT or TCTEASE) do not continue with OLPD. |
PK86692
2009/05/25 |
UK46802-91C |
WRONG CREATION DATE SHOWN IN VSAM DIALOG.
The panel IESFILDETD on vse/iui shows wrong century in four digits for the year of CREATION DATE, such as 2086261 appeared. Since his problem VSAM file was actually created on 1986 (not on 2086) the CREATION DATE should be shown as 1986261. |
PK85480
2009/04/05 |
UK46116-91C |
DEFAULT LIMIT FOR SORTED POWER ENTRIES BY TIME IS SET TO 16. THIS IS TOO LOW.
The default of 16 entries is too low. Default value should be increased to 999. |
PK78884
2009/01/23 |
UK43313-91C |
AICA ABEND FOR IESZATDX LOOP AFTER ITEMERR CONDITION
Loop after an ITEMERR condition after PUTQ request for queue IEZATDNM. The loop ends in an AICA abend. |
PK75152
2008/11/02 |
UK41474-91C |
HARDWAIT FFF STARTING A DYNAMIC PARTITION WITH SAMPLE JOB ACCOUNTING SKJOBACC ACTIVE
Hardwait FFF due to an overlay in the GETVIS control area. Hardwait occurs with job accounting routine SKJOBACC active, starting a dynamic partition. |
PK73367
2008/10/06 |
UK40515-91C |
VSAM BACKUP/RESTORE DIALOG USING SNAP (FASTPATH 3719) GENERATES INVALID JOB
- Job generates an IDCAMS control statement
IMPORT CONNECT OBJECTS(( -
COP -
VOLUMES(TARGET) DEVT(FBA-))) -
CATALOG(VSAM.MASTER.CATALOG)
FBA- is invalid.
- DMPMGR procedure does not erase all dumps if more than 50 dumps exist.
|
PK69759
2008/07/31 |
UK38493-91C |
DOWNLEVEL CHECK WHEN INSTALLING DB2 CLIENT EDITION
Installing DB2 Client Edition on a serviced level like the version that comes with z/VSE 4.1.2, a downlevel check is issued with following APARs and PTFs
PK60248 UK33960
PK61334 UK34588
PK57531 UK34925
PK59102 UK34925
PK55304 UK33736
This is due to a COMPATIBLE WITH statement generated in the install job. |
PK69519
2008/07/25 |
UK36287-91C |
AUDIT LEVEL IN DIALOG IESADMSLE CANNOT BE CHANGED FROM ANYTHING TO 1
The dialog allows to change the audit for a transaction profile from 1 to blank, 2 or 3, but changing back to 1 results in message: AUDIT MUST BE 1, 2, 3 OR BLANK. |
PK69036
2008/07/25 |
UK36286-91E |
CHANGING AUDIT TO 1 FOR TRANSACTION PROFILE ON IUI DIALOG FP2811 GETS MSG1114 WITH NO EXPLANATORY.
On IUI dialog fp-2811 (iesadmbsle - maintain security profiles: resource class tcicstrn), changing an audit to 1 on transaction profile gets an error msg1114, "IESBSTL message 1114 from offset x'0BFA',(key JAMIESJ1114) not in IESTRFL", with no explanatory. The audit to 2 and 3 can be changed on iui fp-2811. A batch job on exec BSTADMIN with CH AUDIT(FAI) can change the audit to 1. |
PK66632
2008/05/08 |
UK36731-91C |
INCORRECT BACKUP JOB GENERATED FOR LABELED TAPE
IUI generated backup job for a library to a labeled tape fails because TAPELABEL parameter is not generated. |
PK64822
2007/04/24 |
UK35743-91E |
ADDING NON ADMINISTRATOR USER ON IUI DIALOG FP 211 GETS MSG1059, THEN THE USER CAN NOT LOGIN DUE TO NO AUTHORIZATION
On IUI dialog fp-211 (iesadmupl2), a new programmer user with type=2 can be added, but gets the error msg - 'IESXUPM message 1059 from offset x'051C',(key JAMIESJ1059) not in IESTRFL'. Then, login with the new profile user can not be allowed due to no authorization to use this application. And there is no explanation for the error msg1059. |
PK64001
2007/04/09 |
UK35317-91C |
BOOTSTRAP RECORDS NEED TO BE RE-WRITTEN AFTER DY46863
- Bootstrap records need to be re-written including IJBLDIPL phase. PTF application dialog needs to be changed.
- Defragmentation of History File should also personalize the history file and reestablish the correct service refresh in the history file.
|
PK58054
2007/12/14 |
UK32229-91C |
IESZATCO DEFAULT MODEL WITH EXTENDED DATASTREAM FOR SNA TERMINAL
In case of cross domain terminals accessing CICS/VSE, the autoinstall exit IESZATCO selects a terminal without extended data stream. |
PK54868
2007/10/24 |
UK30529-91C |
MESSAGE IESA1201 IF INVALID KEY IS USED ON PANEL IESADMDA
On Japanese system, using an invalid key on panel Display System Activity will result in message IESA1201. |
PK50786
2007/08/20 |
UK28382-91C |
SUPPORT OF DB2 7.5
z/VSE 4.1 support for DB2 7.5.0
DFH$SDAP skeleton for CICS shutdown. |
PK54085
2007/10/05 |
UK29797-91C |
WRONG TERMINAL MODEL SELECTED IN CASE OF CROSS DOMAIN TERMINALS
The model type for autoinstall terminals Q........ coming from z/OS NVAS system will always be DFHLU2E2. These are SNA terminals where the wrong autoinstall model is slected. Model DFHLU2E2 does not have a user area TCTUA assigned, thus failing with ICCF. |
PK48951
2007/08/07 |
UK27859-91C |
PROCEDURE UPCNTLSP LEADS TO INCORRECT IESCNTL ENTRIES With following input:
- UPCNTLSP procedure incorrect continuation records and other problems leading to incorrect selection panel records.
- Exit DFHXSE needs to correctly handle a return code of 4 given by the DFHSK macro under CICS/VSE.
|
PK47030
2007/08/07 |
UK27873-91E |
THE NEXT SCREEN OF IUI SECURITY MAINTENANCE SCREEN(FASTPASS 281) WAS INCORRECT. WRONG POTITION AND/OR WRONG CHARACTER. IUI SECURITY MAINTENANCE SCREEN - fastpath 281 shows incorrect data, wrong position and/or wrong |
PK47285
2007/06/28 |
UK26190-91E |
AT IESADMNWU NEWS MENU BY IUI FP34 DBCS JAPANESE CHARACTERS CAN NOT BE ENTERED.
When tring to enter the dbcs Japanese characters at iesadmnwu news menu opened by iui fastpath 34, it can not be entered with an input inhibitted state. The x-mark appears at left side on bottom line on the pannel and protects the input available. |
PK44597
2007/06/14 |
UK24995-91C |
DISPLAY ACTIVE USERS SHOWS CICSUSER AS USERID.
If a user signs on to CICS using CESN and not IUI, the related user shows up as CICSUSER in the Display Active Users dialog. |
PK38656
2007/03/12 |
UK22056-91D |
MISCELLANEOUS FIXES FOR Z/VSE 4.1.0 INTERACTIVE INTERFACE.
Solved PTMs 210, 285, 287.
NLSVERUP not correct. |
PK37980
2007/03/12 |
UK22041-91C |
MISCELLANEOUS FIXES FOR Z/VSE 4.1.0 INTERACTIVE INTERFACE.
Solved PTMs 210, 285, 287.
APAR PK38542.
MXT was set to 20 which is pretty low, only 8 IUI consoles could be started in parallel.
CI size in SKVTAPE was specified for data part only, should be for the whole cluster.
Defragmentation of history file did not work due to the fact that the uncompressed history file (AUX) was copied back to the system history file.
Wrong message
RESOURCE NAME CONTAINS INVALID CHARACTERS. in dialog IESADMBSLA. |
PK37949
2007/03/12 |
UK22041-91C |
ABEND AEIP (INVREQ) IN IESCONSL.
If a PAUSE is set to a value above 59 on an IUI console and if console is put to HOLD, an AEIP abend (INVREQ) occurs. |
PK37948
2007/03/12 |
UK22041-91C |
IESCLEAN SHOULD ISSUE A MESSAGE WHEN CLEANUP PROCESSING IS DONE.
Customer got an abend AZI9 which was caused by IESCLEAN processing. When checking the CICS listing, he complained that cleanup processing does not issue any message. |
| Comp. ID |
CLC |
Description |
| 5686-CF8-01 |
91C |
VSE/SP Unique Code |
| 5686-CF8-02 |
91E |
z/VSE MRI Japanese |
| 5686-CF8-02 |
91D |
z/VSE MRI English |
| 5686-CF8-10 |
91C |
VSE/ICCF |
Last update: January 30, 2009
APAR
Date |
PTF |
Contents |
PK77655
2009/01/22 |
UK43091 - 81C |
AICA ABEND FOR IESZATDX LOOP AFTER ITEMERR CONDITION
Loop after an ITEMERR condition after PUTQ request for queue IEZATDNM. The loop ends in an AICA abend. |
PK71378
2008/10/06 |
UK40441 - 81C |
VSAM BACKUP/RESTORE DIALOG USING SNAP (FASTPATH 3719) GENERATES INVALID JOB
- Job generates an IDCAMS control statement
IMPORT CONNECT OBJECTS(( -
COP -
VOLUMES(TARGET) DEVT(FBA-))) -
CATALOG(VSAM.MASTER.CATALOG)
FBA- is invalid.
- DMPMGR procedure does not erase all dumps if more than 50 dumps exist.
|
PK69831
2008/07/31 |
UK38476 - 81C |
DOWNLEVEL CHECK WHEN INSTALLING DB2 CLIENT EDITION
Installing DB2 Client Edition on a serviced level like the version that comes with z/VSE 4.1.2, a downlevel check is issued with following APARs and PTFs
PK60248 UK33960
PK61334 UK34588
PK57531 UK34925
PK59102 UK34925
PK55304 UK33736
This is due to a COMPATIBLE WITH statement generated in the install job. |
PK66417
2008/05/28 |
UK36721 - 81C |
INCORRECT BACKUP JOB GENERATED FOR LABELED TAPE
IUI generated backup job for a library to a labeled tape fails because TAPELABEL parameter is not generated. |
PK58053
2007/12/14 |
UK32227 - 81C |
IESZATCO DEFAULT MODEL WITH EXTENDED DATASTREAM FOR SNA TERMINAL
In case of cross domain terminals accessing CICS/VSE, the autoinstall exit IESZATCO selects a terminal without extended data stream. |
PK52736
2007/10/05 |
UK29783 - 81C |
WRONG TERMINAL MODEL SELECTED IN CASE OF CROSS DOMAIN TERMINALS
The model type for autoinstall terminals Q........ coming from z/OS NVAS system will always be DFHLU2E2. These are SNA terminals where the wrong autoinstall model is selected. SNA terminals get model DFHLU2E2 selected in case of SNA terminals coming cross domain. |
PK43473
2007/06/14 |
UK24401 - 81E |
SUPPORT FOR 3592 TAPE HARDWARE ENCRYPTION.
Support for tape encryption and other miscellaneous enhancements.
Hardware configuration dialog will be changed, allocation and size parameters for the POWER partition in FSU stage 2 can be up to 6 digits in kilo bytes. |
PK43473
2007/06/14 |
UK24400 - 81E |
SUPPORT FOR 3592 TAPE HARDWARE ENCRYPTION.
Support for tape encryption and other miscellaneous enhancements.
Hardware configuration dialog will be changed, allocation and size parameters for the POWER partition in FSU stage 2 can be up to 6 digits in kilo bytes. |
PK43473
2007/06/14 |
UK24398 - 81D |
SUPPORT FOR 3592 TAPE HARDWARE ENCRYPTION.
Support for tape encryption and other miscellaneous enhancements.
Hardware configuration dialog will be changed, allocation and size parameters for the POWER partition in FSU stage 2 can be up to 6 digits in kilo bytes. |
PK43473
2007/06/14 |
UK24397 - 81A |
SUPPORT FOR 3592 TAPE HARDWARE ENCRYPTION.
Support for tape encryption and other miscellaneous enhancements.
Hardware configuration dialog will be changed, allocation and size parameters for the POWER partition in FSU stage 2 can be up to 6 digits in kilo bytes. |
PK43465
2007/04/26 |
UK24402 - 81C |
DISPLAY ACTIVE USERS SHOWS CICSUSER AS USERID.
If a user signs on to CICS using CESN and not IUI, the related user shows up as CICSUSER in the Display Active Users dialog. |
PK38806
2007/02/12 |
UK21988 - 81H |
STARTING MORE THAN 8 IUI CONSOLES RESULTS IN A HANG.
Wrong maximum value for cylinders in help panel.
TPA tape definition - wrong description. |
PK38806
2007/02/12 |
UK21983 - 81E |
STARTING MORE THAN 8 IUI CONSOLES RESULTS IN A HANG.
Wrong maximum value for cylinders in help panel.
TPA tape definition - wrong description. |
PK38806
2007/02/12 |
UK21982 - 81D |
STARTING MORE THAN 8 IUI CONSOLES RESULTS IN A HANG.
Wrong maximum value for cylinders in help panel.
TPA tape definition - wrong description. |
PK38806
2007/02/12 |
UK21961 - 81A |
STARTING MORE THAN 8 IUI CONSOLES RESULTS IN A HANG.
Wrong maximum value for cylinders in help panel.
TPA tape definition - wrong description. |
PK38542
2007/02/12 |
UK21960 - 81C |
STARTING MORE THAN 8 IUI CONSOLES RESULTS IN A HANG.
Due to the fact that MXT was set to 20 which is pretty low, only 8 IUI consoles could be started in parallel. The MXT value is specified as an overwrite in the startup job.
NCP dialogs rework.
CI size in SKVTAPE was specified for for data part only, should be for the whole cluster.
TPA tape selection in hardware configuration incomplete. |
PK36627
2007/01/08 |
UK21003 - 81C |
ABEND AEIP (INVREQ) IN IESCONSL.
If a PAUSE is set to a value above 59 on an IUI console and if console is put to HOLD, an AEIP abend (INVREQ) occurs. The abend occurs because the timer transaction IECT is started with the specified value of PAUSE as INTERVAL. The syntax for INTERVAL is however hhmmss, so 60 seconds have to be entered as 100. |
PK35764
2006/12/12 |
UK20356 - 81C |
IESCLEAN SHOULD ISSUE A MESSAGE WHEN CLEANUP PROCESSING IS DONE.
Customer got an abend AZI9 which was caused by IESCLEAN processing. When checking the CICS listing, he complained that cleanup processing does not issue any message. |
PK35149
2006/12/05 |
UK20162 - 81A |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK35149
2006/12/05 |
UK20163 - 81D |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK35149
2006/12/05 |
UK20164 - 81E |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK35149
2006/12/05 |
UK20165 - 81H |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK30358
2006/11/28 |
UK20021 - 81E |
AT IESADMNWU NEWS MENU BY IUI FP34 DBCS JAPANESE CHARACTERS CAN NOT BE ENTERED.
When tring to enter the dbcs Japanese characters at iesadmnwu news menu opened by iui fastpath 34, it can not be entered with an input inhibitted state. The x-mark appears at left side on bottom line on the pannel and protects the input available. |
PK34613
2006/11/15 |
UK19659 - 81C |
DEFAULT MODEL FOR NON SNA TERMINALS RESET BY CICS TO A DFHLU0M2.
Customer got message K761I INSUFFICIENT TCTUA SIZE FOR TRMID=L100 this is due to the fact that for a local non SNA terminal model DFHLU0M2 was selected instead of any VSE model with a userarealength of 255. The default type for non SNA terminals should be VSE23782. |
PK33776
2006/11/15 |
UK19662 - 81C |
SECURITY SETUP FOR REPORT CONTROL FEATURE IS INCOMPLETE.
The security definitions for the RCF facilities are correct in skeleton SKRCFSEC, however, GROUP1 should get PERMITS to access.
SKRCFSEC needs to run in order to allow access to RCF printers and reports. With CICS APAR PK11491 installed, a security check will be made (with z/VSE 3.1.1 or later) on all RCF operations like CEOS, CEMS or also EXEC CICS SPOOLOPEN.
This is regardless if the new security concept is used or not. The check will fail unless the RCF facilities are not defined and the related users/groups have access. This is done with skeleton SKRCFSEC. |
PK32566
2006/10/09 |
UK18593 - 81C |
VTAM STARTUP JOB SHOULD REFLECT PRD2.SCEEBASE AND PRD2.PROD IN LIBDEF SETUP.
Customer had added additional steps for DMF reporting and printing CICS statistics to the VTAM startup job. This requires PRD2.SCEEBASE and PRD2.PROD (for DFSORT) in the search chain.
Include PRD2.PROD in search chain and change to temporary LIBDEFS. |
PK30895
2006/09/06 |
UK17740 - 81A |
TRANSLATION ERRORS IN GERMAN SYSTEM
Several explain panels are truncated. |
PK28294
2006/08/01 |
UK16727 - 81C |
ILLEGAL STARTING POSITION SETTING ON REDISPLAY OPERATION GETS ABEND ASRA.
ERRONEOUSLY TYPING -M OR -H AND PRESSING PF7(BWD) TO SKIP ALL logging items of the last minutes or hours and to continue paging backward causes abend asra. In other words, iui fp-31 console redisplay operation gets msgdfhap0001 if there is no number following -(minus) sign.
F2 0103 DFHAP0001 DBDCCICS AN ABEND (CODE 0C7/AKEA) HAS OCCURRED AT OFFSET X'0001A498' IN MODULE IESCONSL
F2 0103 DFHME0116 DBDCCICS (MODULE:DFHMEME) CICS SYMPTOM STRING FOR MESSAGE DFHAP000 IS PIDS/564805400 LVLS/411 MS/DFHAP0001 RIDS/DFHSRP PTFS/VSE411 AB/S00C7 AB/UAKEA RIDS/IESCONSL ADRS/0001A498.
This APAR is related to DY46554. |
PK23632
2006/07/21 |
UK16411 - 81C |
MESSAGE IESA1202 RECEIVED ERROR 13 FROM IESCRIO WHEN SENDING WITH MAP LIBP
Customer got following messages:
IESV0089I FOLLOWING MESSAGE(S) FROM PROGRAM 'IESLIBD', OFFSET X'274C'.
IESA1202I RECEIVED ERROR 13 FROM IESSCRIO WHEN SENDING WITH MAP LIBP.
IESV0089I FOLLOWING MESSAGE(S) FROM PROGRAM 'IESFPIP', OFFSET X'3CA4'.
IESA1202I RECEIVED ERROR 13 FROM IESSCRIO WHEN SENDING WITH MAP ADMSL.
This is mainly driven by the fact that during recovery process, the user map field USRMSAD is not cleared. |
PK27588
2006/07/07 |
UK16034 - 81A |
TRANSLATION ERRORS IN GERMAN SYSTEM
SIP$MSG, message 170 is invalid.
On panel TAS$SEC4 the variable for YES is used wrong (not changed to 1).
Some CICS Panel Helps words are cut after column 68.
On panel IESADMSL.IESGDEF there is a selection 9 shown. |
PK26887
2006/06/29 |
UK15825 - 81C |
IJSYSR1 LIBRARY HAS A RETENTION PERIOD OF 7 DAYS AFTER PTF APPLICATION.
After PTF application, IJSYSR1 has a retention period of 7 days. If a subsequent application is done within this period, overlap on unexpired file message will be issued.
Retention period of IJSYSR1 is 7 days, should be zero days. End of step instead of end of comment in SKBSTSAV. Query models used as default models in autoinstall. |
PK24287
2006/05/12 |
UK14212 - 81C |
PROVIDE BSTCNTL FILE MIGRATION UTILITY Migration tool BSTSAVER is used to migrate BSTCNTL file from z/VSE 3.1.1 to a newer release.
The program saves the contents of the file into a VSE library member which can be used on the new system to load the file.
The library member consists of BSTADMIN control statements.
|
PK21715
2006/03/24 |
UK12887 - 81C |
USER TRANSACTION DOES NOT WORK IF INVOKED BY REXX.
USER transaction does not work if invoked by REXX. IESDUSR only allows console id CNSL and m4lg, this should be extended to also allow console id REXX.
If transaction USER is issued from a REXX procedure by 'MSG xx,DATA=USER' command, there is no output received by the procedure. This is due to the fact, that the transaction checks for the console id. It will only work in case the console id is 'CNSL' or 'm4lg'. It also should allow 'REXX'.
In the procedure the console name used should be REXX: ACTIVATE NAME REXX PROFILE REXNOR |
PK20032
2006/02/24 |
UK12041 - 81C |
ABEND AEIZ IN AUTOINSTALL PROGRAM IESZATDX AFTER LONG TIME NOT RECYCLED.
Abend AEIZ occurred on a WRITEQ TS with APPLNAME. Since CICS was not recycled for a long time and TS is started warm, TS records accumulated.
Autoinstall program contained debug code writing to TS queue without reading or purging records. |
PK19519
2006/02/08 |
UK11519 - 81A |
DISPLAY STORAGE LAYOUT DIALOG DOES NOT WORK ON GERMAN SYSTEM.
There are no values shown for SVA size (24 bit) and all following. Caused by this fact, it is not possible to display storage values for another partition since the entry field for the partition is also overlayed. |
PK17362
2006/01/20 |
UK10909 - 81C |
IESUPDCF SHOULD SUPPORT PROGRAMMER ID TO BE UPDATED.
IESUPDCF does not allow to change the Programmer ID field, to change it, the dialog must be used. IESUPDCF should be extended to allow batch upgrade. |
PK17952
2006/01/18 |
UK10857 - 81E |
APPLICATIONS IN SELECTION PANEL IESADMSL.IESJDEF ARE NOT CORRECT.
On selection IESADMSL.IESJDEF, applications IESJSAM & IESJVTOC do not exist. The selection panel contains invalid application names. |
PK17213
2006/01/02 |
UK10441 - 81H |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK17213
2006/01/02 |
UK10440 - 81E |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK17213
2006/01/02 |
UK10427 - 81D |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK17213
2006/01/02 |
UK10426 - 81A |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK17212
2006/01/02 |
UK10425 - 81C |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK15771
2005/12/01 |
UK09549 - 81C |
JOB ACCOUNTING ROUTINE SKJADACC SHOULD DEFINE VSAM CLUSTER.
Job accounting established with SKJADACC requires a VSAM file SMF.ACCT.FILE. This file should be defined within the skeleton. |
PK15356
2005/11/24 |
UK09359 - 81C |
RESOURCE SECURITY LEVEL MIGRATION SUPPORT.
New security concept introduced with PK10699 allows to define new security resources. Some of the new resources match the RSL type security of CICS/VSE. This APAR will provide migration support for RSL related security definition from CICS/VSE to the new security concept.
- Folowing resources can be migrated to the new security concept using CICS/VSE Migration Aid:
- Files (FCT)
- Journals (JCT)
- Programs (PPT)
- RCF authorized printers (TCT)
- Temporary Storage (TST)
This is done by skeleton SKRSLX2.
- Migration of resources defined in FCT, PCT, DCT, JCT, PCT, PPT or TST souces can be done using skleton SKRSLXS.
- Migration of resources defined in DFHCSDUP format can be done using sleleton SKRSLX3.
- Report of User Profile Maintenance has been enhanced to show the expiration date and the revoke date.
|
PK13189
2005/11/03 |
UK08648 - 81C |
LVTOC SHOWS WRONG FREE SPACE INFORMATION ON FAT DASD WITH MORE THAN 32K CYLINDERS.
- The List VTOC dialog does not show correct values for free space on volumes with more than 32k cylinders.
- Navigator shows wrong data for above devices and also for SCSI devices.
- VSAM backup dialog generates an unexpected continuation line.
- Minor errorr in job accounting routine.
|
PK13556
2005/10/19 |
UK08220 - 81C |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1.
After adding a list of resources to the FACILITY class, a user P001 was included on the access list for the resource DFHRCF.BRSL05
Then in IUI fastpath 281 option 9 was chosen.
In the following panel option 6 = ACCESS LIST was used for DFHRCF.BRSL05.
Pressing ENTER ends in X PROG 755. |
PK12885
2005/10/05 |
UK07819 - 81C |
INITIAL INSTALLATION FAILS WITH MESSAGE IESI0102 WITH EXACTLY 256 OR 257 DISKS CONFIGURED.
With 256 disk devices in IOCP, customer got message MSGIESI0102ASPECIFY IPLADD CMD FOR 54 DASD DEVICES TYPE AS SYSRES.
The logic seems to be wrong checking for minimum configuration. |
PK12555
2005/09/28 |
UK07648 - 81C |
COMMENTS FSU STAGE 2 INCORRECT.
At the end of Stage 2 of FSU, an invalid fastpath was shown in case of an FSU from 2.7.x or a 3.1 refresh. |
PK10701
2005/09/20 |
UK06614 - 81H |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1 (NLS).
New security concept support with Interactive Interface.
New dialog 'Security Maintenance' fastpath 28. |
PK10701
2005/09/20 |
UK06603 - 81E |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1 (NLS).
New security concept support with Interactive Interface.
New dialog 'Security Maintenance' fastpath 28. |
PK10701
2005/09/20 |
UK06578 - 81D |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1 (NLS).
New security concept support with Interactive Interface.
New dialog 'Security Maintenance' fastpath 28. |
PK10701
2005/09/20 |
UK06577 - 81A |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1 (NLS).
New security concept support with Interactive Interface.
New dialog 'Security Maintenance' fastpath 28. |
PK10699
2005/09/20 |
UK06576 - 81C |
NEW SECURITY SUPPORT FOR Z/VSE 3.1.1.
New security concept support with Interactive Interface. New dialog 'Security Maintenance' fastpath 28.
With this BSM control file the BSM does not only protect transactions (resource class name TCICSTRN), it also protects RSL resources with the resource class names ACICSPCT, DCICSDCT, FCICSFCT, JCICSJCT, MCICSPPT, SCICSTST, the logon to CICS as application by class APPL, and the general purpose class FACILITY (used for example by DITTO).
New security concept is defined and maintained using the BSTADMIN utility or using the Interactive Interface dialogs introduced with this APAR.
For more details see following books:
- z/VSE V3R1.1 Planning
- z/VSE V3R1.1 Administration
- CICS TS for VSE/ESA Security Guide, second edition
|
PK11714
2005/09/14 |
UK07222 - 81C |
PARAMETER IN CALL OF ARIPRPC PROCEDURE IS TOO LONG.
Introducing the DBNAME in the DB2 compile skeletons, the maximum length of the PARM operand was not considered. The parameters have to be reworked.
DB2 pre processor program ARIPRPx was issued with a parameter longer than 100 characters. |
PK08467
2005/07/07 |
UK05148 - 81C |
DFHSI1580D VE31CICS PLTPI PROGRAM SUPPDUMP HAS ABENDED, CODE AEIN.
If dump suppression is activated with skeleton SKSUPDMP, DUPREC condition comes up when CICS TS is started WARM or EMER if suppression is activated at PLT time.
CICS startup stops with message:
DFHSI1580D VE31CICS PLTPI program SUPPDUMP has abended,code AEIN.
Reply GO or CANCEL. |
PK06656
2005/06/02 |
UK04038 - 81C |
MESSAGE 'ORIGIN LARGER THAN END' ON PANEL IESFILCFRE DEFINING SPACE
In case of a 3 digit cylinder number for the ending extent on panel IESFILCFRE - Volume Free Space Information, the dialog issues message indicating that the origin of the desired allocation is lower than the end cylinder of the available extent. |
PK04698
2005/04/25 |
UK02709 - 81C |
OLPD DOES NOT HANDLE SRP SECOND OPERAND CORRECTLY. OPERAND AND PSW ANALYSIS IS NOT SHOWN.
OLPD tried to analyze the second operand of an SRP instruction which should not be the case.
PSW and operand analysis is not showing the related storage areas in all cases. |
PK02383
2005/03/21
|
UK01607 - 81C |
DELETE SKELETONS FOR LE LOCALES AND OS 390 API
After FSU, OS/390 API product and LE DBCS Locales are still installed on a version 2 level (products 06675V and 06675M if FSU from 2.7.x, or products 06665V and 06665M in case of an FSU from 2.6.x). Both products should be deleted before the z/VSE 3.1 version is installed.
Job DELTCPIP should not delete phases $SOCKLST, $SOCKOPT and $EDCTCPV.
On Japanese system, using an invalid key on panel Display System Activity will result in message IESA1201. |
PK01182
2005/02/21
|
UK00699 - 81C |
DISPLAY ACTIVE USER LIST INCORRECT AFTER NODE ERROR (DFHZNAC)
Terminating the Display Active Users dialog using the emulation disconnect function (via node error program), after signing on again, all users are displayed twice.
This is due to the fact that the recovery function of IESDUSR works with the terminal id retrieved from the EIB, the EIB however is already cleared.
1. Using a zero terminal id leads to the fact that TS storage does not get freed after a terminal error (DFHZNAC).
More over, if CSNE is defined with TASKDATALOC(ANY), recovery processing for IUI fails with abend AEZC, thus main purpose of the recovery process like freeing allocated storage does not take place.
2. Some CICS Listener Definition Panels (Transaction EZAC) do not correctly display the port number defined for a CICS Listener, if this port number is greater than 32768 (instead of the correct port number, a number smaller than 32768 is displayed).
The same problem exists for the EZACIC02 listener (transaction EZAL) when issueing EZY messages that include port numbers in their text.
1. In following routines, the recovery process was changed:
IESBQUR Batch Queue Maintenance
IESDUSR Display Active Users
IESIMSG Retrieve Message from ICCF
IESLQDP Display Message Log
IESNEWS Maintain News Record
IESVTOCR Display VTOC
IESXSYN Maintain Synonym Table
INWMPRIN Print HTF Member
INWMRXS1 HTF fulist
INWMRXS5 Move file HTF to ICCF
INWMSHAR HTF share a file
2. Ensure display of correct port numbers. |
PK01123
2005/02/21
|
UK00689 - 81C |
SUPPRESS OLPD SCREEN FOR ABENDS AZCT AND ATNB
After a time out happened using DITTO edit function, abend AZCT followed by an ATNB is issued. For both abends, OLPD should not try to send any data to the terminal thus suppress the display of the OLPD user screen. |
| Comp. ID |
CLC |
Description |
| 5686-CF7-01 |
81C |
VSE/SP Unique Code |
| 5686-CF7-02 |
81H |
z/VSE MRI Spanish |
| 5686-CF7-02 |
81E |
z/VSE MRI Japanese |
| 5686-CF7-02 |
81D |
z/VSE MRI English |
| 5686-CF7-02 |
81A |
z/VSE MRI German |
| 5686-CF7-10 |
81C |
VSE/ICCF |
Last update: December 12, 2006
APAR
Date |
PTF |
Contents |
PK35451
2006/12/11 |
UK20315 - 75C |
IESCLEAN SHOULD ISSUE A MESSAGE WHEN CLEANUP PROCESSING IS DONE.
Customer got an abend AZI9 which was caused by IESCLEAN processing. When checking the CICS listing, he complained that cleanup processing does not issue any message. |
PK35097
2006/11/23 |
UK19852 - 75C |
VTAPE START JOB FOR SERVER PARTITION SHOULD ALLOW DIFFERENT TCP/IP PARTITIONS.
Startup job SKVTASTJ uses default suffix '00' for TCP/IP.
A // OPTION SYSPARM='00' should be added to the skeleton to show what to change in case of using multiple TCP/IP partitions. |
PK34612
2006/11/23 |
UK19813 - 75A |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK34612
2006/11/23 |
UK19814 - 75D |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK34612
2006/11/23 |
UK19815 - 75E |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK34612
2006/11/23 |
UK19816 - 75H |
DISPLAY SYSTEM ACTIVITY DIALOG SHOULD SHOW CURRENT ACTIVE TRANSACTIONS.
The display system activity dialog shows Peak Active user transactions, this value is not as meaningful as the current active number of user transactions. |
PK30826
2006/10/09 |
UK18591 - 75C |
VTAM STARTUP JOB SHOULD REFLECT PRD2.SCEEBASE AND PRD2.PROD IN LIBDEF SETUP.
Customer had added additional steps for DMF reporting and printing CICS statistics to the VTAM startup job. This requires PRD2.SCEEBASE and PRD2.PROD (for DFSORT) in the search chain.
Include PRD2.PROD in search chain and change to temporary LIBDEFS. |
PK23850
2006/05/22 |
UK14657 - 75C |
ILLEGAL STARTING POSITION SETTING ON REDISPLAY OPERATION GETS ABEND ASRA.
ERRONEOUSLY TYPING -M OR -H AND PRESSING PF7(BWD) TO SKIP ALL logging items of the last minutes or hours and to continue paging backward causes abend asra. In other words, iui fp-31 console redisplay operation gets msgdfhap0001 if there is no number following -(minus) sign.
F2 0103 DFHAP0001 DBDCCICS AN ABEND (CODE C7/AKEA) HAS OCCURRED AT OFFSET X'0001A498' IN MODULE IESCONSL.
F2 0103 DFHME0116 DBDCCICS (MODULE:DFHMEME) CICS SYMPTOM STRING FOR MESSAGE DFHAP000 IS PIDS/564805400 LVLS/411 MS/DFHAP0001 RIDS/DFHSRP PTFS/VSE411 AB/S00C7 AB/UAKEA RIDS/IESCONSL ADRS/0001A498
This APAR is related to DY46513. |
PK19892
2006/02/20 |
UK11867 - 75C |
ABEND AEIZ IN AUTOINSTALL PROGRAM IESZATDX AFTER LONG TIME NOT RECYCLED.
Abend AEIZ occurred on a WRITEQ TS with APPLNAME. Since CICS was not recycled for a long time and TS is started warm, TS records accumulated.
Autoinstall program contained debug code writing to TS queue without reading or purging records. |
PK18513
2006/01/25 |
UK11104 - 75A |
(SIP) MESSAGE 141 CONTAINS SEQUENCE NUMBERS IN COLUMN 72-80.
Message 141 has sequence numbers in colunm 72-80.
Message is not displayed, text of message is:
JOBNAME-PREFIX OF THE GENERATED JOB(S) is "DMP" (E.G. &).
Deleting VSE dumps via IUI in his VSE/ESA 2.7.3 leads to error message.
Member DTRLFRE2 shows message:
SETMSG PRB$IDH 0124 SETMSG MG04 SIP 141 SIP$MSG. |
PK16071
2005/12/19 |
UK10213 - 75H |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK16071
2005/12/19 |
UK10212 - 75E |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK16071
2005/12/19 |
UK10210 - 75D |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK16071
2005/12/19 |
UK10209 - 75A |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK15903
2005/12/19 |
UK10189 - 75C |
MOVE UTILITY FROM HTF TO VSAM DOES NOT TELL IF DUPLICATE RECORDS WERE ENCOUTERED.
Customer had duplicate records on the source file.
He got message
MOVE SUCCESSFULLY COMPLETED; 009030 RECORDS WERE MOVE
but the target, a KSDS, only showed 8671 records.
He wanted a different message indicating that duplicate records where encountered. This duplicate records message will also be shown in case of a move into an existing KSDS cluster if records are to be replaced. |
PK11025
2005/09/14 |
UK07122 - 75C |
PARAMETER IN CALL OF ARIPRPC PROCEDURE IS TOO LONG.
Introducing the DBNAME in the DB2 compile skeletons, the maximum length of the PARM operand was not considered. The parameters have to be reworked.
DB2 pre processor program ARIPRPx was issued with a parameter longer than 100 characters. |
PK08401
2005/07/07 |
UK05120 - 75C |
DFHSI1580D VE31CICS PLTPI PROGRAM SUPPDUMP HAS ABENDED, CODE AEIN.
If dump suppression is activated with skeleton SKSUPDMP, DUPREC condition comes up when CICS TS is started WARM or EMER if suppression is activated at PLT time.
CICS startup stops with message:
DFHSI1580D VE31CICS PLTPI program SUPPDUMP has abended,code AEIN.
Reply GO or CANCEL. |
PK06653
2005/06/02 |
UK04022 - 75C |
MESSAGE 'ORIGIN LARGER THAN END' ON PANEL IESFILCFRE DEFINING SPACE
In case of a 3 digit cylinder number for the ending extent on panel IESFILCFRE - Volume Free Space Information, the dialog issues message indicating that the origin of the desired allocation is lower than the end cylinder of the available extent. |
PK04689
2005/04/25 |
UK02707 - 75C |
OLPD DOES NOT HANDLE SRP SECOND OPERAND CORRECTLY. OPERAND AND PSW ANALYSIS IS NOT SHOWN.
OLPD tried to analyze the second operand of an SRP instruction which should not be the case.
PSW and operand analysis is not showing the related storage areas in all cases. |
PK03547
2005/04/07 |
UK02124 - 75 C |
ICCF SUBMIT TRUNCATES USER-DEFINED JECL KEYWORD OPERANDS. No message is issued.
The workarea size has been doubled and message K895I has been introduced:
K895I VSE/ICCF LIMIT FOR USER-DEFINED JECL KEYWORD OPERANDS EXCEEDED
ICCF Submit supports now the 5 Digit VSE/POWER DUETIME operand |
PK03488
2005/04/04 |
UK01992 - 75C |
DFHAP0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'0000024A' IN MODULE IESOPIA
Customer got:
DFHAP0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'0000024A' IN MODULE IESOPIA
DFHAP0001 AN ABEND (CODE ---/ASRA) HAS OCCURRED IN EXIT PROGRAM IESOPIA AT EXIT POINT XPCABND.
The problem occurred in a CICS that did not have enough storage available. |
PK00764
2005/02/18 |
UK00616 - 75C |
DISPLAY ACTIVE USER LIST INCORRECT AFTER NODE ERROR (DFHZNAC)
Terminating the Display Active Users dialog using the emulation disconnect function (via node error program), after signing on again, all users are displayed twice.
This is due to the fact that the recovery function of IESDUSR works with the terminal id retrieved from the EIB, the EIB however is already cleared.
1. Using a zero terminal id leads to the fact that TS storage does not get freed after a terminal error (DFHZNAC).
More over, if CSNE is defined with TASKDATALOC(ANY), recovery processing for IUI fails with abend AEZC, thus main purpose of the recovery process like freeing allocated storage does not take place.
2. Some CICS Listener Definition Panels (Transaction EZAC) do not correctly display the port number defined for a CICS Listener, if this port number is greater than 32768 (instead of the correct port number, a number smaller than 32768 is displayed).
The same problem exists for the EZACIC02 listener (transaction EZAL) when issueing EZY messages that include port numbers in their text.
1. In following routines, the recovery process was changed:
IESBQUR Batch Queue Maintenance
IESDUSR Display Active Users
IESIMSG Retrieve Message from ICCF
IESLQDP Display Message Log
IESNEWS Maintain News Record
IESVTOCR Display VTOC
IESXSYN Maintain Synonym Table
IESXSYN Maintain Synonym Table
INWMPRIN Print HTF Member
INWMRXS1 HTF fulist
INWMRXS5 Move file HTF to ICCF
INWMSHAR HTF share a file
2. Ensure display of correct port numbers. |
PQ99437
2005/01/18 |
UQ96900 |
SUPPRESS OLPD SCREEN FOR ABENDS AZCT AND ATNB
After a timeout happened using DITTO edit function, abend AZCT followed by an ATNB is issued. For both abends, OLPD should not try to send any data to the terminal thus suppress the display of the OLPD user screen. |
PQ98402
2004/12/20 |
UQ96205 |
ABEND AKEA 0C4 IN IESFPIP OFFSET '0C0E'X
In case a connection error (DFHZNAC) occurs while sign on processing is active, the sign on program passes control to IESFPIP without further checking. |
PQ97480
2004/11/22 |
UQ95259 |
ABEND AEZD IN PROGRAM IESDUSR
IESDUSR is also called in case of recovery, so it should run in execution key CICS.
Abend AEZD happened for program IESDUSR in case of recovery processing got activated after a networking problem (DFHZNAC). |
APAR
Date |
PTF |
Contents |
PQ95597
2004/10/15 |
UQ93838
|
MINOR TRANSLATION ERRORS IN VSE/ESA 2.7 JAPANESE
- IESFILCSPC ........
CYLINDERS OR BLOCKS / TRACKS should be CYLINDERS OR TRACKS / BLOCKS
- IESFILCSPC help page 2 of 2
but no second page exists
|
PQ95426
2004/10/12 |
UQ93741
|
MINOR TRANSLATION ERRORS IN VSE/ESA 2.7 GERMAN
- User Profile Maintainance: Neue Funktion PRINT: NACHRICHT 0669 VON IESXUPM , POS.X'049C',(SCHL.GAMIESG0669 ) NICHT IN IESTRFL.
- SIP msg typo
AUSWAHL VON VIRTUELLEM BAND FÜR FSU: VSAM-DATINAME ERFORDERLICH.
- IESFILCSPC BEREICH ANZEIGEN (display VSAM Space)
ZYLINDER ODER BLÖCKE / SPUREN
should be
ZYLINDER ODER SPUREN / BLÖCKE
- IESFILCSPC BEREICH ANZEIGEN (display VSAM Space)
help page 2 of 2 but no second page exists
- Define Space IESFILSDEF DEFINE CATALOG SPACE
Help page 3 of 3 wrong wording.
- Invalid comment in NLSVERDL
- PRB$IDHE SPEICHERAUSZÜGE LÖSCHEN
Help page 3 wrong procedure name
- >WEITERE DATEIEN..............#12 < on panel DSF$SNP5,
not possible to enter anything.
|
PQ92086
2004/09/15 |
UQ91059
|
SUPPORT OF DB2 7.4 IN VSE/ESA 2.7.
Installation and FSU will support DB2 7.3.
Compile dialogs and stored procedure samples changed to reflect the new release. |
PQ93348
2004/08/30 |
UQ92264
UQ92245
UQ92244
UQ92243 |
DISPLAY ACTIVE USERS SHOWS CONSOLE USERS WITH PRESET SECURITY.
- Console users with preset security (defined as terminal with a userid assigned) will show up on the display active user dialog. The dialog checks for a non blank OPID field.
- Customer has more than 99 pages of active users. Page numbering starts at page 0 or one after page 99. Page numbering should be 3 digits.
|
PQ93346
2004/08/30 |
UQ92238
|
DISPLAY ACTIVE USERS SHOWS CONSOLE USERS WITH PRESET SECURITY.
- Console users with preset security (defined as terminal with a userid assigned) will show up on the display active user dialog. The dialog checks for a non blank OPID field.
- Customer has more than 99 pages of active users. Page numbering starts at page 0 or one after page 99. Page numbering should be 3 digits.
|
PQ93354
2004/08/27 |
UQ92189
|
AICA IN AUTOINSTALL PROGRAM IESZATDX
The loop occurred after an INQUIRE TERMINAL getting INVEQ. This condition was not handled correctly. |
PQ92624
2004/08/23 |
UQ91992
|
3590-TPA DEVICES ARE NOT LISTED IN PRODUCT INSTALLATION DIALOG
Some of the IUI dialogs will not allow to use 3590 addresses. A message is issued that the drive is invalid.
The default file definition for various files of the Interactive Interface were defined with STRINGS(1).
To allow parallel usage, STRINGS was increased. |
PQ90883
2004/07/26 |
UQ90444
UQ90443
UQ90438
UQ90437 |
ON A LARGE DASD 3390, VSAM SPACE VALUES ARE INCORRECT ON PANEL IESFILCSP
Panel IESFILSPC shows incorrect values for a big 3390 device. NLS part. |
PQ90882
2004/07/26 |
UQ90410
|
ON A LARGE DASD 3390, VSAM SPACE VALUES ARE INCORRECT ON PANEL IESFILCSP
IUI panel IESFILCSPC is showing incorrect VSAM information on D/T3390. LISTCAT showing cylinders instead of tracks for large devices. |
PQ89761
2004/06/17 |
UQ89596
|
TRANSACTION EZAL IS RECEIVING MESSAGE CEE3200S AND AICA ABEND
The CICS trace shows an AICA abend in transaction EZAL.
Problem shows up due to the performance improvements with TCP/IP 15D.
The AICA seems to be caused by a loop.
The loop is due to incompletely clearing of a mask larger than 256. |
PQ89307
2004/05/27 |
UQ88804
|
AUTOINSTALL FOR CROSS DOMAIN TERMINALS FAILS
- Autoinstall for cross domain terminals fail with an abend AICA and message DFHZC2404.
- Flashcopy VSAM dialog should allow labeled tapes and also unload or rewind the tape.
- SKICFRST will not restore all system parts in the non NLS library. IMVERUP.Z should be used.
- Printer models and non SNA terminals had IOAREALEN(256,0). This leads to problems printing reports on terminal printers using the report control feature. Length changed to IOAREALEN(1024,4096).
|
PQ88605
2004/05/19 |
UQ88494
|
MESSAGE M432I DURING PTF APPLICATION
PTF application of a PSP bucked ended in message
M432I AUXILIARY HISTORY FILE CONTAINS INVALID RBA F1FFFF.LAST VALID RBA WAS 000000
Problem still there after compression of history file and switching off OEM software. It finally turned out that increasing the partition size solved the problem.
- No SIZE parameter in the EXEC MSHP step of PTF application job stream. In case the SIZE value for the partition is different than the specified value in the ALLOC procedure, PTF application may fail.
- PSW pointing to an invalid address was not validated using VALADDR routine.
|
PQ86925
2004/04/08 |
UQ86991
|
ABENDS ASRA AND ASRA WITH OLPD PROGRAM IESOPIA
- Abend ASRA in ASRA processing:
DFHSR0001 TPCICT1
An abend (code 0C4/AKEA) has occurred offset X'FFFFFFFF' in program CPGTQMU.
DFHAP0701 TPCICT1
An abend (code 0C4/AKEA) has occurred in exit program IESOPIA at exit point XPCABND.
DFHAP0001 TPCICT1
An abend (code 0C4/AKEA) has occurred offset X'00000B02' in module IESOPIA.
- No PAUSE statement generated to mount the tape.
- Definition of the CRYPTO library should be for master catalog, otherwise a job catalog will be used.
- Dump Management dialog did check for CICS/VSE Report Control feature instead of CICS/VSE production part.
|
APAR
Date |
PTF |
Contents |
PQ84675
2004/02/13 |
UQ85076
|
ABEND TB04 IN HARDWARE CONFIGURATION DIALOGUE.
Abend TB04 occurred due to an invalid line.
Remove line
d$$021**3590-TPATAPE 9 TPA 08 3590ZZ
in DTR$DEVT in ICCF library 50. |
PQ80874
2004/01/22 |
UQ82911
UQ82908
UQ82906
UQ82852 |
VARIOUS MINOR ERRORS VSE/ESA 2.7
Support of 3592 tape drive (NLS) in Interactive Interface |
PQ80873
2004/01/22 |
UQ82851
|
VARIOUS MINOR ERRORS VSE/ESA 2.7
- Transaction security dialog does not work correctly in case of non standard LIBDEF chain.
- Supervisor generation skeleton change size of workfile IJSYS03.
- Allow own POWER phase and allocation in case of a release upgrade using FSU.
- Run program DTRIPSTL in FSU Preparation to make sure correct product setup is used in FSU Installation.
- Job accounting using DMF:
- For fast CPUs avoid program check in case of a zero value for CPU TIME count.
- New parameter JSTEPO for ACCTREP report program - report by job steps.
- Allow also 8 character synonym models for utility IESUPDCF.
- FSU allow e-distributed installation tape.
- Support of 3592 tape drive in Interactive Interface.
- New enhanced report function on user profiles and transaction security settings.
|
PQ81441
2003/11/28 |
UQ82521
UQ82519
UQ82517
UQ82514 |
USER PROFILE MAINTENANCE DIALOG ALLOWS UPDATE ON READ ONLY CONTROL FILE (NLS)
If IESCNTL is defined to CICS with BROWSE and READ accesss only, User Profile Maintenance allows to add or alter users without any message about read only access. The added user does not show up in the control file, alters do not take place. |
PQ81297
2003/11/28 |
UQ82510 |
USER PROFILE MAINTENANCE DIALOG ALLOWS UPDATE ON READ ONLY CONTROL FILE
If IESCNTL is defined to CICS with BROWSE and READ accesss only, User Profile Maintenance allows to add or alter users without any message about read only access. The added user does not show up in the control file, alters do not take place. |
PQ79918
2003/10/24 |
UQ81352 |
TIMEMAXEX VALUE FOR ICCF USERS NOT CORRECT IF LARGER THAN 32768
If the TIMEMAXEX value is changed to a value higher than 32768 using the user profile maintenance dialog, any subsequent usage of the dialog will reset the specified value to
32768 - entered value.
Customer had set to 65535 which resulted in a TIMEMAXEX value of 1. Such a low value causes problems since the related user hardly can run any ICCF task in the pseudo partition.
SKTCPSTR, SKVCSSTJ and SKVTASTJ need to be changed.
Delete FSU stage 2 jobs from IJSYSRS |
PQ78158
2003/09/12 |
UQ79989 |
SKDFHDU ASSGN FOR SYS009 (PRINTER) IS MISSING
SKDFHDUP and print jobs PRTDUMPA, PRTDUMPB, PRTDUC2A and PRTDUC2B are not correct, the assignment for SYSLST is missing.
A security check will be done before invoking the transaction.
Generating multiple NCP lines ends with a TB01 abend (too many tables open). |
PQ76821
2003/07/29 |
UQ78793
UQ78792
UQ78791
UQ78790 |
DATA BASE NAME IN COMPILE DIALOGS SHOULD BE ALLOWED TO HAVE 18 CHARACTERS (NLS)
Currently, the compile dialog for DB2 allows only an 8 character data base name.
DB2 allows 18 characters.
It would be more convenient to specify this in the dialog than modifying the related C$Q... skeleton. |
PQ76818
2003/07/29 |
UQ78785 |
DATA BASE NAME IN COMPILE DIALOGS SHOULD BE ALLOWED TO HAVE 18 CHARACTERS (NLS)
Currently, the compile dialog for DB2 allows only an 8 character data base name.
DB2 allows 18 characters.
It would be more convenient to specify this in the dialog than modifying the related C$Q... skeleton. |
PQ76622
2003/07/29 |
UQ78757 |
CICS LISTENER, AEIV ABEND IN APPLICATION PROGRAM USING LISTENER
Abend AEIV (LENGERR) occurred in an application program using CICS Listener function EXEC CICS RETRIEVE.
This is due to a change of length of the CICS Listener output area. |
PQ76822
2003/07/28 |
UQ78782
(ICCF) |
ICCF TERMINAL TIMEOUT SETTING OF exactly 3600 seconds does not work. DTSICCF has been changed to use the correct hhmmss specification for EXEC CICS START TRANSID INTERVAL. |
PQ76078
2003/07/11 |
UQ78283 |
CICS SOCKET LISTENER GETS AN ABEND0C4 AT X'12' IN EZACIC02
CICS socket listener gets ABEND0C4 at x'12' in EZACIC02.
It was going along processing 200 requests when it abended.
The Program Check occurs because EZACIC02, offset 13B2, branches into an area with no executable code.
This branch is done out of an EXEC CICS call:
EXEC CICS INQUIRE,
TRANSACTION(EISSECTR),
PROGRAM(EISPGM),
....
Since this is not the first EXEC CICS call from EZACIC02, it see that there could be an overlay somewhere. |
PQ75840
2003/07/08 |
UQ78183 |
ABEND ASRA IN IND$ FILE TRANSFER IF NOT SIGNED ON TO IUI
IND$ file transfer gets an abend ASRA in case the user is not signed on through IUI (IESN) but CESN. |
APAR
Date |
PTF |
Contents |
PQ76075
2003/07/09 |
UQ78274 |
AUTO INSTALL EXIT IESZATDX DOES NOT WORK FOR CROSS DOMAIN TERMINALS.
A TERMIDERR is raised but the code seems to be '000000FF'.
This is due to a destroyed register for the DFHEIB control block. |
PQ73692
2003/06/27 |
UQ76755 |
SUPPORT OF DB2 7.3.0 IN VSE/ESA 2.7
Support of DB2 7.3.0 for initial installation, FSU, compile dialogs and connectors.
Installation and FSU will support DB2 7.3.
Compile dialogs and stored procedure samples changed to reflect the new release. |
PQ74581
2003/06/12 |
UQ77517 |
TRANSLATION ERROR ON DISPLAY SYSTEM ACTIVITY PANEL
At panel IESADMDA (path 361) field DISPATCHABLE and MXT REACHED translated wrong. |
PQ71197
2003/03/11 |
UQ74429 |
GA PTF FOR VSE/ESA 2.7.0
If customer uses skeleton SKTCPSTR to modify the TCP/IP startup job, after FSU the modification is lost.
The same is true for:
- SKCICS, modification of CICSICCF job,
- SKVTAM, modification of VTAMSTRT job,
- SKVTASTJ, modification of startup job VTAPE server partition,
- SKCICS2, modification of PRODCICS job,
- SKCICSOL, modification of CICSOLD job and
- SKVCSSTJ, modification of startup job for connector server.
- Changed DLBL for C/VSE message file old label was 'C370 ...'.
- User modified startup jobs for TCP/IP, VTAM, virtual tape server partition, secondary CICS, CICS/VSE and the connector server partition should be kept during FSU.
- FSU step DTRFSU15 is jumping over the assign for the tape drive in case of resume.
- Skeleton SKWRKFIL has an invalid ASSGN statement. In addition, the allocation for workfile 3 is too small.
|
PQ71145
2003/03/11 |
UQ74429 |
OLPD DOES NOT WORK AFTER A CERTAIN AMOUNT OF TIME
With PQ57091 we introduced an eye catcher for the OLPD global work area which hold the SVL address.
We additionally introduced code to validate the SVL.
If the SVL is not properly passed on to OLPD, we switched off OLPD.
We did not find out who destroys the global work area. The eye catcher of the work area is 'OLPD_GWA'.
Instead of terminating OLPD processing, we should try to load the SVL using XPI load services.
This will establish a backup way for OLPD to produce incident data. |
PQ71097
2003/03/11 |
UQ74429 |
INSTALLING CICS/VSE, COMPATIBLE WITH STATEMENT ONLY GENERATED FOR DEFAULT LIBRARIES.
Installing CICS/VSE from the extended base tape, M233I is issue in case of using different target library/sublibrary than the default.
The same is true for DB2 base and the Data Propagator feature.
In addition, installing DB2 from the optional product tape, the install dialog does not install it into PRD2.DB2720. |
| Comp. ID |
CLC |
Description |
| 5686-066-01 |
75C |
VSE/SP Unique Code |
| 5686-066-02 |
75H |
VSE/ESA MRI Spanish |
| 5686-066-02 |
75E |
VSE/ESA MRI Japanese |
| 5686-066-02 |
75D |
VSE/ESA MRI English |
| 5686-066-02 |
75A |
VSE/ESA MRI German |
| 5686-066-10 |
75C |
VSE/ICCF |
 |
Last update: March 20, 2006
APAR
Date |
PTF |
Contents |
PK21559
2006/03/20 |
UK12710 - 65C |
JOB ACCOUNTING ROUTINE SKJADACC SHOULD DEFINE VSAM CLUSTER
Job accounting established with SKJADACC requires a VSAM file SMF.ACCT.FILE. This file should be defined within the skeleton.
Replace DMF based job accounting routine using OS390 API by SMF type solution. |
PK11986
2005/09/19 |
UK07345 - 65C |
DFHAP0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'0000022A' IN MODULE IESOPIA
Customer got DFHAP0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'0000022A' IN MODULE IESOPIA.
DFHAP0001 AN ABEND (CODE ---/ASRA) HAS OCCURRED IN EXIT PROGRAM IESOPIA AT EXIT POINT XPCABND.
The problem occurred in a CICS that did not have enough storage available. |
PK08488
2005/07/08 |
UK05214 - 65C |
TRANSACTION EZAC DOES NOT DISPLAY CORRECT PORT NUMBER IF THIS IS LARGER THAN 32768.
Some CICS Listener Definition Panels (Transaction EZAC) do not correctly display the port number defined for a CICS Listener, if this port number is greater than 32768 (instead of the correct port number, a number smaller than 32768 is displayed).
The same problem exists for the EZACIC02 listener (transaction EZAL) when issueing EZY messages that include port numbers in their text. |
PK05661
2005/05/13 |
UK03369 - 65C |
MESSAGE 'ORIGIN LARGER THAN END' ON PANEL IESFILCFRE DEFINING SPACE
In case of a 3 digit cylinder number for the ending extent on panel IESFILCFRE - Volume Free Space Information, the dialog issues message indicating that the origin of the desired allocation is lower than the end cylinder of the available extent. |
PK04605
2005/04/25 |
UK02706 - 65C |
OLPD DOES NOT HANDLE SRP SECOND OPERAND CORRECTLY. OPERAND AND PSW ANALYSIS IS NOT SHOWN.
OLPD tried to analyze the second operand of an SRP instruction which should not be the case.
PSW and operand analysis is not showing the related storage areas in all cases. |
PK00029
2005/02/09 |
UK00271 - 65C |
DISPLAY ACTIVE USER LIST INCORRECT AFTER NODE ERROR (DFHZNAC)
Terminating the Display Active Users dialog using the emulation disconnect function (via node error program), after signing on again, all users are displayed twice.
This is due to the fact that the recovery function of IESDUSR works with the terminal id retrieved from the EIB, the EIB however is already cleared.
Clean up processing for several IUI routines does not work properly due to wrong terminal id used.
In addition, the node error transactions CSNE needs to be change to TAKDATALOC(BELOW).
Using a zero terminal id leads to the fact that TS storage does not get freed after a terminal error (DFHZNAC).
More over, if CSNE is defined with TASKDATALOC(ANY), recovery processing for IUI fails with abend AEZC, thus main purpose of the recovery process like freeing allocated storage does not take place. |
PQ99943
2005/01/25 |
UQ97092 - 65C |
ABEND AEZD IN PROGRAM IESDUSR
IESDUSR is also called in case of recovery, so it should run in execution key CICS.
Change CSD definition for IESDUSR.. |
PQ99380
2005/01/18 |
UQ96878 |
SUPPRESS OLPD SCREEN FOR ABENDS AZCT AND ATNB
After a timeout happened using DITTO edit function, abend AZCT followed by an ATNB is issued. For both abends, OLPD should not try to send any data to the terminal thus suppress the display of the OLPD user screen. |
PQ98001
2004/12/14 |
UQ96050 |
ABEND AKEA 0C4 IN IESFPIP OFFSET '0C0E'X
In case a connection error (DFHZNAC) occurs while sign on processing is active, the sign on program passes control to IESFPIP without further checking. Sign on program IESIES01 should pass control to the function processor only in case the terminal is available. In case the terminal is gone due to a connection problem (DFHZNAC), sign on should perform a return. |
PQ97284
2004/11/18 |
UQ95163
(ICCF) |
ICCF SUBMIT TRUNCATES USER-DEFINED JECL KEYWORD OPERANDS. No message is issued.
The workarea size has been doubled and message K895I has been introduced:
K895I VSE/ICCF LIMIT FOR USER-DEFINED JECL KEYWORD OPERANDS EXCEEDED |
PQ94095
2004/09/15 |
UQ92766
UQ92762
UQ92751
UQ92744 |
ON A LARGE DASD 3390, VSAM SPACE VALUES ARE INCORRECT ON PANEL
- Panel IESFILSPC shows incorrect values for a big 3390 device.
- IUI panel IESFILCSPC is showing incorrect VSAM information on D/T3390.
- LISTCAT showing cylinders instead of tracks as it should be.
|
PQ94094
2004/09/15 |
UQ92743 |
ON A LARGE DASD 3390, VSAM SPACE VALUES ARE INCORRECT ON PANEL
- Panel IESFILSPC shows incorrect values for a big 3390 device.
- IUI panel IESFILCSPC is showing incorrect VSAM information on D/T3390.
- LISTCAT showing cylinders instead of tracks as it should be.
|
PQ93343
2004/08/26 |
UQ92186 |
AICA IN AUTOINSTALL PROGRAM IESZATDX
The loop occurred after an INQUIRE TERMINAL getting INVEQ. This condition was not handled correctly. |
PQ92629
2004/08/12 |
UQ91631
(ICCF) |
Starting transaction ICCF in CICS partition without ICCF causes message DFHAP0001 ABEND0C4 at X'00004154' in DTSICCF. DTSICCF in CICS2 worked with addresses from CICSICCF and abended while reading in fetch protected CICS2 storage. DTSICCF now checks if ICCF is running in the partition which started transaction ICCF. |
PQ91106
2004/07/27 |
UQ90932 |
TRANSACTION EZAL IS RECEIVING MESSAGE CEE3200S AND AICA ABEND
The CICS trace shows an AICA abend in transaction EZAL. The problem seems to be related to the $SOCKOPT phase. Problem shows up due to the performance improvements with TCP/IP 15D. Make sure if masks larger than 256 bytes are used, that everything is cleared properly. |
PQ89264
2004/05/25 |
UQ88794 |
AUTOINSTALL FOR CROSS DOMAIN TERMINALS FAILS
- Autoinstall for cross domain terminals did not work. Message DFHZC2404 is issued and abend AICA for transaction CATA occured.
- Flashcopy VSAM dialog should allow labeled tapes and also unload or rewind the tape.
|
PQ88042
2004/05/06 |
UQ87874 |
MESSAGE M432I DURING PTF APPLICATION
PTF application of a PSP bucked ended in message
M432I AUXILIARY HISTORY FILE CONTAINS INVALID RBA F1FFFF. LAST VALID RBA WAS 000000
Problem still there after compression of history file and switching off OEM software.
It finally turned out that increasing the partition size solved the problem.
- No SIZE parameter in the EXEC MSHP step of PTF application job stream. In case the SIZE value for the partition is different than the specified value in the ALLOC procedure, PTF application may fail.
- PSW pointing to an invalid address was not validated using VALADDR routine.
|
PQ84985
2004/03/31 |
UQ86714 |
ABENDS ASRA AND ASRA WITH OLPD PROGRAM IESOPIA
After an AKEA abend code 0C4 in a user program, OLPD exit program IESOPIA abended with an AKEA 0C4 offset 'B02'x.
- Abend ASRA in IESOPIA - address validation needs to be extended.
- FSU release upgrade - enhance JCL for defining crypto library in case a job catalog is used, the library is not defined in master catalog.
|
PQ78040
2003/09/05 |
UQ79782 |
SKDFHDU ASSGN FOR SYS009 (PRINTER) IS MISSING
The skeleton to print transaction dumps SKDFHDUP is not setup correctly, an assignment for the printer is missing. |
PQ76621
2003/07/28 |
UQ78752 |
CICS LISTENER, AEIV ABEND IN APPLICATION PROGRAM USING LISTENER
Abend AEIV (LENGERR) occurred in an application program using CICS Listener function EXEC CICS RETRIEVE.
This is due to a change of length of the CICS Listener output area. |
PQ75830
2003/07/28 |
UQ78589
UQ78586
UQ78579
UQ78578 |
DATA BASE NAME IN COMPILE DIALOGS SHOULD BE ALLOWED TO HAVE 18 CHARACTERS (NLS)
Currently, the compile dialog for DB2 allows only an 8 character data base name.
DB2 allows 18 characters.
It would be more convenient to specify this in the dialog than modifying the related C$Q... skeleton. |
PQ75245
2003/07/28 |
UQ78573 |
DATA BASE NAME IN COMPILE DIALOGS SHOULD BE ALLOWED TO HAVE 18 CHARACTERS
Currently, the compile dialog for DB2 allows only an 8 character data base name.
DB2 allows 18 characters.
It would be more convenient to specify this in the dialog than modifying the related C$Q... skeleton. |
PQ76077
2003/07/10 |
UQ78277 |
CICS SOCKET LISTENER GETS AN ABEND0C4 AT X'12' IN EZACIC02
CICS socket listener gets ABEND0C4 at x'12' in EZACIC02.
It was going along processing 200 requests when it abended.
The Program Check occurs because EZACIC02, offset 13B2, branches into an area with no executable code.
This branch is done out of an EXEC CICS call:
EXEC CICS INQUIRE,
TRANSACTION(EISSECTR),
PROGRAM(EISPGM),
....
Since this is not the first EXEC CICS call from EZACIC02, it see that there could be an overlay somewhere. |
 |
APAR
Date |
PTF |
Contents |
PQ76347
2003/07/15 |
UQ78477 |
FSU STEP DTRFSU22 FAILS IN CASE OF A RELEASE UPGRADE
Message NO HDR1 LABEL FOUND is issued due to the fact that part SKCICCLD is restored twice in IMVERUP.Z. |
PQ76072
2003/07/08 |
UQ78268 |
AUTO INSTALL EXIT IESZATDX DOES NOT WORK FOR CROSS DOMAIN TERMINALS.
Auto install exit IESZATDX does not work for cross domain terminals.
A TERMIDERR is raised but the code seems to be '000000FF'.
This is due to a destroyed register for the DFHEIB control block. |
PQ74563
2003/06/27 |
UQ77766 |
SUPPORT OF DB2 7.3.0 IN VSE/ESA 2.6
Support of DB2 7.3.0 for initial installation, FSU, compile dialogues and connectors.
Installation and FSU will support DB2 7.3.
Compile dialogs and stored procedure samples changed to reflect the new release. |
PQ74252
2003/05/27 |
UQ77061 |
SIGNON PROCESSING SHOULD ALLOW TCTUALOC=ANY FOR PRODCICS
The customer has specified the CICS SIT parm TCTUALOC=ANY.
The parm controls where the TCT USER AREA is getmained.
When specifying ANY the area is allocated as a 31bit address above. The module IESIES01 runs in 24 bit mode.
With the TCTUA above IESIES01 gets an ABEND0C4 offset x'7E6'.
TCTUALOC=ANY is only allowed for production CICS, DBDCCICS requires TCTUALOC=BELOW due to ICCF running in this CICS. |
PQ74562
2003/05/27 |
UQ77056 |
TRANSLATION ERROR ON DISPLAY SYSTEM ACTIVITY PANEL
At panel IESADMDA (path 361) fields DISPATCHABLE and MXT REACHED are translated wrong. |
PQ73863
2003/05/09 |
UQ76601 |
ESCAPE TO VM WITH AN OFFSET UNEQUAL TO 1 IS NOT WORKING
Customer had set an offset of 4 in IESJLOGO, but with this offset, PF3 EXIT to VM was not shown. |
PQ70752
2003/02/21 |
UQ74141 |
OLPD IS NOT WORKING ANYMORE AFTER A CERTAIN AMOUNT OF TIME
With PQ57091 we introduced an eye catcher for the OLPD global work area which hold the SVL address.
We additionally introduced code to validate the SVL.
If the SVL is not properly passed on to OLPD, we switched off OLPD. The customer did not find out who destroys the global work area. The eye catcher of the work area is 'OLPD_GWA'.
Instead of terminating OLPD processing, we should try to load the SVL using XPI load services.
This will establish a backup way for OLPD to produce incident data. |
PQ70697
2003/02/18 |
UQ74036 |
INSTALLING CICS/VSE, COMPATIBLE WITH STATEMENT ONLY GENERATED FOR DEFAULT LIBRARIES.
Installing CICS/VSE from the extended base tape, M233I is issued in case of using different target library/sublibrary than the default.
The same is true for DB2 base and the Data Propagator feature.
In addition, installing DB2 from the optional product tape, the install dialog does not install it into PRD2.DB2720. |
PQ70277
2003/01/28 |
UQ73479
(ICCF) |
- GETL fails if jobnames start with the character combination of QC. Checking for QC operand in DTSGETQ has been removed.
- If VSE/ICCF message exit routine DTSMSGS gets control from the console router at a specific stage during ICCF shutdown, it can cause a program check or hardwait. DTSMSGS now checks in the ICCF vector table if ICCF is terminating
|
PQ68047
2002/10/12 |
UQ72242 |
MESSAGE IESV1002 DISPLAYING A HIGH NUMBER OF SELECTION PANELS OR APPLICATION PROFILES
- Message IESV1002 displaying a high number of selection panels or application profiles.
- Bad performance pressing SORT by name key in ICCF Program Development dialog. Only sort by size is expected to have a lower performance.
- Minor problem in REXX program DMPMGR.
- Extending to new range of possible terminals in auto install exit IESZATDX did not work properly in all cases.
- Enhancements in job accounting print routine SKJOBDMF.
- Abend in dialog FlashCopy VSAM Catalog /Files.
|
 |
APAR
Date |
PTF |
Contents |
PQ66568
2002/10/16 |
UQ70722 |
SUPPORT OF NEW DSF REL 1.17 IN VSE 2.6
- Support of DSF 1.17
- Invoking $$BIESVM by a program (SVC2) - interface changed. Larger output area.
- CRYPTO library not secured, invalid entry in DTSECTRC.
- PF3 key exit to VM not shown on sign on panel.
- Auto install exit IESZATDX extend range of possible terminals, default is from A000 - A999, B000 - B999, ... J000 - J999.
- Enhance error handling in DTRMRG procedure for indirect PTF application. Procedure will issue error comments on console in case of problems.
|
PQ65715
2002/09/24 |
UQ69983 |
ABEND IE08 SIGNING OFF A USER RUNNING SELECTION PANEL MAINTENANCE DIALOG
- Abend IE08 signing off a user running application profile maintenance or selection panel maintenance with logon here, or display active user dialog.
- Storage violation may occur if a user running the IUI console gets a timeout or is signed off by logon here, or display active users dialog.
- Uppercase translation also of message explanation text in case IESJDEF or IJBJDEF default is set to uppercase.
- New parameters for dump management procedure DMPMGR to allow deletion of dumps by age or date.
- Continuation card wrong in DFHDCTCO.
- Changes in programmable interface for sign on program IESIES01.
- Minor problem in FSU - install DB2.
- Allocation of VSAM space for master catalog not correct in case of FBA 9336 Model 10 disks. End VTOC will be hit.
- Autoinstall with more than 999 terminals does not switch to the next prefix.
|
PQ65790
2002/09/02 |
UQ69397
UQ69396
UQ69392
UQ69385 |
SET DEFAULT STARTUP MODE FOR TEMPORARY STORAGE TO COLD
- Default setting for temporary storage startup was TS=(,8,8), should be changed to TS=(COLD,8,8).
- Member NLSVERUP was not correct for German, Japanese and Spanish system.
|
PQ62813
2002/07/31 |
UQ68571 |
SKELETON SKPREPC2 SHOULD FIRST APPEND DFHLIST AND THEN ADD GROUP VSESPG
The changed process for invoking node error program IESCLEAN via program link need CSNE to be defined with a TWASIZE of 400.
Changing was done with APAR PQ61787. For the standard CICS DBDCCICS, the change gets active immediately, for the CSD list VSELST2 used for PRODCICS, the change does not get active because the setup in SKPREPC2 is appending DFHLIST as last step to VSELST2.
In addition, new program skeletons for suppressing CICS dumps (SKSUPDMP) and for the GETVIS xx,RESET command issued via CCS transaction (SKCCMD) are added to ICCF library 59.
- CSD setup modified to first append DFHLIST to VSELST2. This will make sure the modified CSNE transaction is defined with TWASIZE 400.
- New skeleton SKCICMD will establish a transaction and program to allow GETVIS xx,RESET command issued from CICS. This program can also be invoked during PLT startup. The GETVIS xx,RESET was established with DY45817.
- New skeleton SKSUPDMP to establish a program to suppress dumps and to force dumps in case of storage violations.
- Enhancement for dump management procedure DMPMGR to allow automatic dump processing by age.
- New skeleton SKCCERT to establish sample client certificates.
- TCP/IP startup job, PFIX incorrect. Any value above 16 MB may only be specified in case there is real storage above.
|
PQ61787
2002/06/07 |
UQ66892 |
CICS SHUTDOWN TAKES ABOUT 20 MINUTES
In case connection of several terminals is going down, lots of IENP transactions are started. With the delay parameter active, this slows down CICS shut down.
In order to return to the former used EXEC CICS LINK IESCLEAN, IESCLEAN needs to be changed to address mode 31 (as a CICS EXIT). Since IESCLEAN clears storage allocated by other routines in so called recovery mode, need to be changed to Execkey(CICS) (all programs are in group VSESPG. |
PQ61749
2002/06/06 |
UQ66837 |
SUPERVISOR GENERATION DURING PTF APPLICATION SHOULD INCLUDE DELTA LIBRARIES IN SEARCH CHAIN
- Supervisor generation skeleton SKSUPASM and the PTF application job stream should refer to the delta libraries PRD2.GEN1D and PRD1.MACLIBD which should be in search chain ahead of PRD2.GEN1 and PRD1.MACLIB.
- Release upgrade from 2.4 and 2.5 should add a label for CRYPTO library.
- CSD migration tool SKSECTXS will allow PCT entries without TRANSEC and add them to the transaction security definition with security class 1.
- Minor typos in skeleton SKJOURO.
- DFHDCTCO should not trigger IEWR transaction.
|
PQ61103
2002/05/17 |
UQ66336 |
IESBLDUP DOES NOT SETUP AF SECURITY FLAGS CORRECTLY.
IESBLDUP fails to set the AF security bits correctly for ADMIN or PROGrammer type users.
Migrating from a VSE/ESA 2.5 system, the migration utility tools SKSECTXS, SKSECTX2 and SKSECTX3 do not generate correct IPF tables for the merge function.
In addition, the merge function of dialog Transaction Security should support old type IPF tables generated by 2.5. |
 |
APAR
Date |
PTF |
Contents |
PQ60447
2002/04/30 |
UQ65608 |
INVALID VTAM STARTUP BOOK TCPAPP00.B
During startup, messages
IST1249I SYNTAX ERROR AT RECORD 2 IN MEMBER ATCCON00
IST258I STMT IN ERROR = * TCPAPP00, *
IST018I CONFIG COULD NOT BE INITIALIZED - VTAM START CONTINUES
IST523I REASON = ERROR READING VTAMLST FILE
IST314I END
occur.
This is due to a comment line not followed by any valid application definition. |
PQ60250
2002/04/24 |
UQ65315
UQ65311 |
STORAGE VIOLATION CODE X'0F0C' IN DISPLAY ACTIVITY ROUTINE IESXDA
IUI SYSTEM ACTIVITY DISPLAY ( 361 , IESADMDA ) results in message:
DFHSM0102 'A storage violation (code X'0F0C') has been detected by mdule DFHSMAR
Registers are pointing to IESXDA offset '1358'x. |
PQ60136
2002/04/18 |
UQ65160 |
STORAGE VIOLATION CODE X'0F0C' IN DISPLAY ACTIVITY ROUTINE IESXDA
IUI SYSTEM ACTIVITY DISPLAY ( 361 , IESADMDA ) results in message:
DFHSM0102 'A storage violation (code X'0F0C') has been detected by mdule DFHSMAR
Registers are pointing to IESXDA offset '1358'x. |
PQ57744
2002/04/15 |
UQ64166
UQ64163
UQ64162
UQ64161 |
SEVERAL MINOR PROBLEMS WITH VSE/ESA 2.6
- Dump management, new CICS region IE added to the dialog.
- TCP/IP configuration dialog allows to also generate the VTAM application definition for Telnet daemons.
- New dialog Maintain Certificates - User IDs.
- DFHSITSP and DFHSITC2 changed.
|
PQ57743
2002/04/15 |
UQ64160 |
SEVERAL MINOR PROBLEMS WITH VSE/ESA 2.6
- Dump management, new CICS region IE added to the dialog.
- TCP/IP configuration dialog allows to also generate the VTAM application definition for Telnet daemons.
- New keys and certificates valid until March 2003.
- New dialog Maintain Certificates - User IDs.
- PTF application, error handling in DTRMRG procedure enhanced. In case of an out-of-space situation during the merge, return code of 8 will show up.
- IESBLDUP sample job, add PAUSE statement with instructions how to close IESCNTL in BSM and CICS.
- Minor setup problems with CICS/VSE coexisting environment, startup job and skeleton to define journal files was wrong.
- Default allocation values for skeleton SKVTAPE were too high
|
PQ58394
2002/02/27 |
UQ63464
(ICCF) |
- /SKIP PREVIOUS (PF7) while browsing an XMIT QUEUE ENTRY always skips to top. VSE/ICCF did not check if a transmit queue entry is of type reader and used for number of lines field from the VSE/POWER SPL ( SPLDLCT ). This field is hex zero and led to the false positioning. ICCF command processor DTSTX03 uses now field SPLDRCT
- &&MAXLOOP order is used to specify the maximum permissible loop value before the procedure is cancelled. The default value is 150 and the maximum is 4096. This number was to small for some users. The limitation of 4096 for &&MAXLOOP in DTSPROCS has been removed. It's still recommended to stay with the default setting and use the increased limit with caution. This has been documented in the VSE/ICCF User's Guide.
|
PQ57985
2002/02/26 |
UQ63013
UQ63012
UQ63011
UQ63010 |
PANEL IESFILDETG SHOWS NUMBER OF CIs FOR EXTENDED KSDS DATASETS
- Panel IESFILDETG shows number of bytes, but in case of an extended KSDS, the used High RBA field from VSAM does not contain the number of bytes but the number of control intervals.
The panel should show both.
- For the German, the Spanish and the Japanese system, the release upgrade from 2.4.x and 2.5.x will not work, message 4113D NO HDR1 LABEL FOUND is issued in FSU step 22 B.
Circumvention is to reset to step 23, job DTRFSU23 using the job manager.
The NLS part of the ICCF library has to be restored after the FSU is completed using step 2 of the job in skeleton SKICFRST in ICCF library 59.
|
PQ57099
2002/02/19 |
UQ62795 |
SHOW PF4 REMOTE APPLICATIONS ON SIGNON SCREEN ONLY IN CASE THERE ARE REMOTE APPLICATIONS
- PF4 key is used to jump back to a VTAM USS10 message (SNA) or the VSE TCPIP MENUE panel when there is one defined.
When the customer has defined the TARGET=DBDCCIC in his TELNETD there is no function behind the key '4=REMOTE APPLICATIONS'.
The customer states that his users gets confused when there is no function behind a key which is displayed to him.
We should add some logic to display the key only for certain terminals, for example the ones defined with the terminal attribute DISCREQ=NO.
- Allow program call to IESIES01 in order to sign on to Interactive Interface.
|
PQ57091
2002/02/14 |
UQ62733 |
OLPD IMPROVE CHECKING OF PARTITION ALLOCATION VALUES WHEN EXPLOITING ABEND OPERANDS
- In case of an abend, the operands of the failing instruction are exploited by OLPD. With CICS TS, storage boundaries are not stored in the CSA and there is no CICS TS service allowing to retrieve the boundaries. So the storage boundaries of the CICS partition are calculated by means of the EXTRACT information.
|
PQ57220
2002/02/01 |
UQ62331 |
MSGBSST24I AFTER APPLICATION OF TCP/IP SERVICE PACK 1.4C
- After application of TCPIP for VSE service pack 1.4C message "BSST24I ACCESS DENIED DUE TO UNSUPPORTED REQUEST. TYPE = 14 FTYPE = 00" is returned from BSSTISX security module on FTP requests.
CSI International has confirmed that the SXBLOK layout has been modified in this service pack and BSSTISX needs to be changed to support the new SXBLOK layout.
|
PQ56819
2002/01/25 |
UQ62060 |
STORAGE VIOLATION (CODE X'0F0C') DURING CICS SHUT DOWN
A storage violation (code X'0F0C') detected DFHSMAR. One of the transaction storage trailer SAA was overlaid.
The buffer provided to hold output for a CEMT I TA command is obviously too small. |
PQ56556
2002/01/15 |
UQ61805 |
OPERATION EXCEPTION USING VIRTUAL TAPE SERVER, CONNECTOR SERVER AND OTHER C/VSE PROGRAMS
- Using virtual tape server or the connector server on a IBM R21 (SIR output: PROCESSOR = 9672-33) gives an operation exception on a CHI instruction OP code 'A7rE'
This operation code is generated by a wrong level C compiler used with VSE/ESA 2.6.0.
There might also be other instructions/OP codes generated which are not supported by this hardware.
|
PQ56865
2002/01/23 |
UQ61941 |
SIGNON ROUTINE IESIES01 INVOKES USER EXIT WITH NAME IESEXIT.
- The sample exit SKEXIT1 uses IESEXIT1 as name, also the Administration guide refers to this name, however, the signon program IESIES01 invokes exit program IESEXIT.
|
PQ56186
2002/01/10 |
UQ61657 |
FSU RELEASE UPGRADE FROM 2.4 OR 2.5 TO 2.6 WITH GENERATION FEATURE INSTALLED FAILS.
- If upgrade of the generation feature is selected on panel SRV$FS03, step 16, job DTRFSU16 fails with message 1F33D PARAMETER XLAST NOT DEFINED .
|
PQ55969
2002/01/07 |
UQ61359
UQ61356
UQ61352
UQ61351 |
SEVERAL FIXES FOR INTERACTIVE INTERFACE VSE/ESA 2.6.0 PTF 1
- DFHSITSP and DFHSITC2 changed MSGLVL back to 1 (was 0).
- Minor errors on panel help information for panels: PRB$IDHD, SRV$PH02 and SRV$PH03.
|
PQ55920
2001/12/24 |
UQ61350 |
SEVERAL FIXES FOR INTERACTIVE INTERFACE VSE/ESA 2.6.0 PTF 1
- DFHSITSP and DFHSITC2 changed MSGLVL back to 1 (was 0).
- Analyzing a CICS TS dump should run in a larger partition than BG by default.
- Skeleton SKJADACC had an invalid object deck.
- SKVTAPE should define the virtal tape cluster with share option 1 instead of 2.
- Shut down PLTs modified instructions concerning DFH0STAT.
|
PQ54702
2001/12/10 |
UQ60218 |
STORAGE LAYOUT SHOULD ALSO SHOW VALUES FOR REXX APPLICATIONS
Using Display Storage Layout and it looks like all fields are blank when running any REXX program. It's as if there is nothing in the partition. |
PQ54701
2001/12/10 |
UQ60218 |
SEVERAL FIXES FOR INTERACTIVE INTERFACE VSE/ESA 2.6.0 PTF 1
- DFHDCTCO comments where to insert entries are not correct.
- DUMPINIT should establish CICS/VSE dump analysis routine DFHDAP in the external routine file. If CICS/VSE is set up without using SKPREPCO or SKPREPSO, dumps can not be analyzed.
- Allow one character userids to be migrated from an SNT.
- Change COMPATIBLE WITH handling for optional product installation for products DB2 and CICS/VSE. PTM PV030197STU.
- Comments in SKIWSTF not removed completely by @DTRSEXIT.
- Compatibility group DFHCOMP2 incorrect in preparation member SKPREPSO, should be DFHCOMP1.
- Not all comments removed in skeleton SKPWRGEN.
- Changed default values and comments in skeleton SKVTAPE.
- MERGIP procedure should not issue messages. PTM PV030069HOH
- If a PORT is specified in the product installation dialog and a VSAM file name, 474 should be issued: YOU MAY EITHER SPECIFY VSAM FILE OR IP ADDRESS
|
| Comp. ID |
CLC |
Description |
| 5686-066-01 |
65C |
VSE/SP Unique Code |
| 5686-066-02 |
65H |
VSE/ESA MRI Spanish |
| 5686-066-02 |
65E |
VSE/ESA MRI Japanese |
| 5686-066-02 |
65D |
VSE/ESA MRI English |
| 5686-066-02 |
65A |
VSE/ESA MRI German |
| 5686-066-10 |
65C |
VSE/ICCF |
 |
Last update: February 25, 2005
APAR
Date |
PTF |
Contents |
PQ78869
2003/09/25 |
UQ80409
(ICCF) |
- GETL fails if jobnames start with the character combination of QC. Checking for QC operand in DTSGETQ has been removed
- If VSE/ICCF message exit routine DTSMSGS gets control from the console router at a specific stage during ICCF shutdown, it can cause a program check or hardwait. DTSMSGS now checks in the ICCF vector table if ICCF is terminating
|
PQ76522
2003/07/22 |
UQ78245 |
CICS LISTENER, AEIV ABEND IN APPLICATION PROGRAM USING LISTENER
Abend AEIV (LENGERR) occurred in an application program using CICS Listener function EXEC CICS RETRIEVE. This is due to a change in length of the CICS Listener output area.
|
PQ75736
2003/07/08 |
UQ78245 |
CICS SOCKET LISTENER GETS AN ABEND0C4 AT X'12' IN EZACCI02
CICS socket listener ABEND0C4 at x'12' in EZACIC02. The Program Check occurs because EZACIC02, offset 13B2, branches into an area with no executable code. This branch is done out of an EXEC CICS call:
EXEC CICS INQUIRE,
TRANSACTION(EISSECTR),
PROGRAM(EISPGM),
....
Since this is not the first EXEC CICS call from EZACIC02, it is possible that there could be an overlay somewhere. |
PQ65460
2002/09/02 |
UQ69376 |
ABEND IE08 SIGNING OFF A USER RUNNING SELECTION PANEL MAINTENANCE DIALOG
- Abend IE08 signing off a user running application profile maintenance or selection panel maintenance with logon here, or display active user dialog.
- Storage violation may occur if a user running the IUI console gets a timeout or is signed off by logon here, or display active users dialog.
- Uppercase translation also of message explanation text in case IESJDEF or IJBJDEF default is set to uppercase.
- Typos in SKJOURO.
|
PQ58998
2002/05/13 |
UQ65844 |
CICS SHUTDOWN TAKES ABOUT 20 MINUTES
After APAR PQ52476, the CICS hang did not occur anymore, but due to the DELAY(1) parameter inserted in IESZNEP, CICS shutdown takes about 20 minutes. |
PQ60449
2002/05/03 |
UQ65777 |
ABEND AKEA IN PROGRAM IESSCRIO OFFSET '177E'X
- MESSAGE: DFHSR0001 A40CICS2 An abend (code 0C1/AKEA) has occurred at offset X'0000177E' in program IESSCRIO.
- SYMPTOMS: PIDS/564805400 LVLS/411 MS/DFHSR0001 RIDS/DFHSRP PTFS/VSE411 AB/S00C1 AB/UAKEA RIDS/IESSCRIO ADRS/0000177E
Problem happens randomly, is related to user applications with own user modified panel selection and possibly help function. |
PQ57607
2002/02/19 |
UQ62868
UQ62867
UQ62866
UQ62865
|
PANEL IESFILDETG SHOWS NUMBER OF CIs FOR EXTENDED KSDS DATASETS
Panel IESFILDETG shows number of bytes, but in case of an extended KSDS, the used High RBA field from VSAM does not contain the number of bytes but the number of control intervals.
The panel should show both. |
PQ57473
2002/02/11 |
UQ62545
UQ62544
UQ62543
UQ62539 |
SEVERAL MINOR PROBLEMS WITH VSE/ESA 2.5
- Storage dump management dialog shows DLI as parameter analyzing CICS TS dumps. DLI is not valid.
In order to dump application related parts, AP should be added to the default options.
- SIT parameter BMS changed to BMS=(FULL,,UNALIGN,NODDS). This avoids AEI9 abends sending maps.
|
PQ57472
2002/02/11 |
UQ62537
|
SEVERAL MINOR PROBLEMS WITH VSE/ESA 2.5
- Storage dump management dialog shows DLI as parameter analyzing CICS TS dumps. DLI is not valid.
In order to dump application related parts, AP should be added to the default options.
- DFH0STAT program is shipped as a sample with CICS TS to print CICS statistics. This program needs to be compiled with the Cobol/VSE compiler before it can be used. Users without having the compiler installed cannot use the program.
- COMPATIBLE WITH statement installing DB2 and CICS/VSE should only get generated in case the installed product is DB2 or CICS.
- SKJADACC skeleton invalid object deck included, this leads to link errors.
- Invalid CSD compatibility group DFHCOMP2 in skeleton SKPREPSO. Group is obsolete.
- In case of a return code of 8, the merge procedure should not continue processing.
- SIT parameter BMS changed to BMS=(FULL,,UNALIGN,NODDS). This avoids AEI9 abends sending maps.
|
PQ57217
2002/02/01 |
UQ62330
|
MSGBSST24I AFTER APPLICATION OF TCP/IP SERVICE PACK 1.4C
- After application of TCP/IP for VSE service pack 1.4C message "BSST24I ACCESS DENIED DUE TO UNSUPPORTED REQUEST. TYPE = 14 FTYPE = 00" is returned from BSSTISX security module on FTP requests.
CSI International has confirmed that the SXBLOK layout has been modified in this service pack and BSSTISX needs to be changed to support the new SXBLOK layout.
|
PQ55927
2002/01/28 |
UQ62166
|
SHOW PF4 REMOTE APPLICATIONS ON SIGNON SCREEN ONLY IN CASE THERE ARE REMOTE APPLICATIONS
- PF4 key is used to jump back to a VTAM USS10 message (SNA) or to the VSE TCP/IP MENUE panel when there is one defined.
When the customer has defined the TARGET=DBDCCIC in his TELNETD there is no function behind the key '4=REMOTE APPLICATIONS'.
The customer states that his users gets confused when there is no function behind a key which is displayed to him.
We should add some logic to display the key only for certain terminals, for example the ones defined with the terminal attribute DISCREQ=NO.
|
PQ55137
2002/01/28 |
UQ62143
|
OLPD IMPROVE CHECKING OF PARTITION ALLOCATION VALUES WHEN EXPLOITING ABEND OPERANDS
- In case of an abend, the operands of the failing instruction are exploited by OLPD.
With CICS TS, storage boundaries are not stored in the CSA and there is no CICS TS service allowing to retrieve the boundaries.
So the storage boundaries of the CICS partition are calculated by means of the EXTRACT information.
|
PQ56618
2002/01/22 |
UQ62080
|
SIGNON ROUTINE IESIES01 INVOKES USER EXIT WITH NAME IESEXIT.
- The sample exit SKEXIT1 uses IESEXIT1 as name, also the Administration guide refers to this name, however, the signon program IESIES01 invokes exit program IESEXIT.
|
PQ56424
2002/01/22 |
UQ61932
|
STORAGE VIOLATION (CODE X'0F0C') DURING CICS SHUT DOWN
- A storage violation (code X'0F0C') detected DFHSMAR. One of the transaction storage trailer SAA was overlaid.
The buffer provided to hold output for a CEMT I TA command is obviously too small.
|
| |
PQ57333
2002/01/02 |
UQ62365
(ICCF) |
- /SKIP PREVIOUS (PF7) while browsing an XMIT QUEUE ENTRY always skips to top. VSE/ICCF did not check if a transmit queue entry is of type reader and used for number of lines field from the VSE/POWER SPL ( SPLDLCT ). This field is hex zero and led to the false positioning.
ICCF command processor DTSTX03 uses now field SPLDRCT
- &&MAXLOOP order is used to specify the maximum permissible loop value before the procedure is cancelled. The default value is 150 and the maximum is 4096. This number was to small for some users.
The limitation of 4096 for &&MAXLOOP in DTSPROCS
has been removed. It's still recommended to stay with the default setting and use the increased limit with caution.This has been documented in the VSE/ICCF User's Guide.
|
PQ54326
2001/11/09 |
UQ59597
|
STORAGE LAYOUT SHOULD ALSO SHOW VALUES FOR REXX APPLICATIONS
- Using Display Storage Layout and it looks like all fields are blank when running any REXX program.
It's as if there is nothing in the partition.
|
PQ49437
2001/11/06 |
UQ54941
(ICCF) |
- VSE/ICCF high priority task has been cancelled by the supervisor with cancel code x'21'. This means ' an invalid SVC was isued. The issued SVC was a MODFLD SVC 107 ( x'6B' ). Problem only happened when this specific task has come to EOT. VSE/ICCF high priority task now checks if the task has come to EOT before it issues the SVC. Otherwise the normal EOJ processing by the high priority task is performed.
- LOOP in SUBMIT to POWER program DTSSUBMT holds a table with all VSE/POWER * $$ LST operands. An entry has besides other's the name of the operand, the entry length and an output area. DTSSUBMT analyzes the user's * $$ LST card and steps true the table using the entry lengths. One length entry has been overwritten and caused the pointer register working in an area with all hex zeros. The overlay happened while processing
the DEST operand. Reason for the loop was that step register content became negative. DTSSUBMT has been changed, that step register content will never be negative.
|
PQ52832
2001/10/23 |
UQ59064
|
MIGRATE JOB NEEDS IESCNTL TO BE CLOSED IN ORDER TO RUN.
- Running the "Migrate step" during initial installation, the control file is already open by the VSE security manager.
Thus the IESBLDUP step does not run.
Customer has to close the file with command MSG FB,DATA=CLOSECNTL and resume.
- Some users have userids defined with less than 4 characters.
Such users are defined in the SNT.
IESBLDUP utility will allow such users to be migrated (as type 3 users).
|
PQ53317
2001/10/16 |
UQ58570
|
TRANSLATION ERROR IN MESSAGE 106 OF SIP$MSG LEADS TO II ABEND MG04
- Using the dialog to backup a VSAM file (fastpath 3713) results in II abend MG04 for SIP$MSG 106. The original message is 69 characters long and has two message inserts.
The problem occurs entering extents with more than 4 digits.
|
PQ52476
2001/09/26 |
UQ57993
|
LOTS OF IENP TRANSACTIONS BEING STARTED BRINGS CICS TS DOWN
- CICS does not answer to MSG F2 commands due to the fact that MXT is reached. For some reason VTAM closed which resulted in a bunch of IENP transactions being started automatically. This causes MXT to be reached and no further task can be started.
- With UQ57162 applied, after signing on, any entered data on screen IESADMIN puts the user back to the signon screen.
|
PQ51655
2001/09/07 |
UQ57448
|
FILE TRANSFER WITH CC OPTION CREATES WRONG PAGER HEADER LINES IN CASE OF LOGICAL RECORD LENGTH LARGER THAN 255
- With the CC option and record larger than 256 bytes ('100'x) first byte of the 8 byte record prefix is kept, and the remaining 7 bytes are overwritten by the record. Since record length is larger than 256, in the specific case it is '10C'X, only 'C'X bytes are shifted since the field SAVRECLN is limited to 256.
- There is no operator communication possible after message IESI0222I is displayed on the console.
- With storage protection on message DFHAP0001 abend code 0C4/ADEA has occurred offset '02E'x in IESCLEAN.
|
PQ51586
2001/08/22 |
UQ57060
|
ABEND AEIP IN TRANSACTION IEGM, PROGRAM IESSCRIO OFFSET X'54C'
- The AEIP occurred with an EXEC CICS FREEMAIN where the address was odd.
The FREEMAIN in IESSCRIO is only done in case the terminal has the katakana feature defined.
|
PQ50867
2001/08/22 |
UQ57162
|
STORAGE VIOLATION FOR DIRECT USERS IN PANEL HIERARCHY LIST
- The storage overlay is in a storage accounting area, the pattern 'F0'x is changed to 'EF'x and two bytes further, is changed to 'F5' (NI 'FD'x).
The second overlay is in the task the first one in the second byte of the SAA.
First overlay is a minus one in the first half word.
|
PQ52832
2001/10/23 |
UQ59064
|
MIGRATE JOB NEEDS IESCNTL TO BE CLOSED IN ORDER TO RUN.
- Running the "Migrate step" during initial installation, the control file is already open by the VSE security manager.
Thus the IESBLDUP step does not run.
Customer has to close the file with command MSG FB,DATA=CLOSECNTL and resume.
- Some users have userids defined with less than 4 characters.
Such users are defined in the SNT.
IESBLDUP utility will allow such users to be migrated (as type 3 users).
|
 |
APAR
Date |
PTF |
Contents |
PQ50346
2001/07/11 |
UQ55743
|
POST/BASE PROCESSING SHOWS PANEL IESADMSE4
- Your user profile requires that you be connected to the application defined by application profile IMARY Su directly after Sign On.
That application profile either does not exist or has invalid contents.
|
PQ50144
2001/07/03 |
UQ55477
|
ABENDAEY9 WHEN PF1 KEY IS PRESSED TO GET HELP INFORMATION ON PANEL IESBQUC
- Customer has installed a VSE/ESA 2.5.1 with GERMAN language.
Default CICS/TS 1.1.1 (ICCFCICS) is used.
When PF1 (HELP) at panel IESBQUC (IN-CRATION-QUEUE ; fastpath 326) is pressed an ABENDAEY9 ( transaction IESR ) comes up.
Pressing the HELP (PF1) button on other panels works well.
|
PQ50082
2001/06/28 |
UQ55397
|
INVALID APPLICATION PROFILE FOR POST/BASE
- POST/BASE processing gets message that the required primary application is invalid.
- DFHPEP does not return after XCTL to IESOPDC. So it does not make sense to retrieve the return code.
- EXEC CICS XCTL should be replaced by EXEC CICS LINK to allow customer modifications after IESOPDC comes back.
- IESCLEAN does not handle TCTUA above correctly, it should be able to handle TCTUA's above.
|
PQ49527
2001/06/15 |
UQ55036
|
REFRESH KEY IN PROGRAM DEVELOPMENT PANEL SPECIFYING A PREFIX NOT WORKING CORRECT FOR A PROGRAMMER ID
- If a programmer user id specifies a prefix on panel IESLIBP, he will see all members in the specified library not only the members he owns. Pressing the refresh key (PF2) will show only his own members.
- Group DFHCOMP2 is not defined in CSD after initial installation.
|
PQ49301
2001/06/10 |
UQ54935
|
STORAGE VIOLATION ON AN IUI SEND MAP IF CSFE IS ACTIVE
- If the CSFE trap is set active, most of the IUI panels cause a strage violation on a SEND MAP command.
The customer ran with CSFE DEBUG,CHKSTSK=ALL and has a dump that was created (SM0103).
The dump shows that the violation occurred during a SEND map and the RET address is pointing to IESSCRH 00535750 DFHYA410 00535750 410 LEN(8D2).
The RET address from the SEND MAP was x'00535A10' or offset x'2C0' in IESSCRH.
|
PQ48871
2001/05/25 |
UQ54353
|
PARSING ERROR IN IESWAITR,
DEBUGGING AID FOR IESZATDX
- IESWAITR procedure does not parse all output of VSE/POWER in the correct way.
The procedure should be written to handle all possible POWER configurations.
- In case of no model is provided in the terminal definition, IESZATDX will log an empty record on the TS queue.
A log should only be written in case a model is provided.
- Support for NCP 7.8.1 and ACF/SSP 4.8.1.
|
PQ46864
2001/04/02 |
UQ52845
|
MESSAGE SOURCE LANGUAGE OF THE ABENDING PROGRAM IS NOT DEFINED
- Each abend in a COBOL program will issue message: The source language of the abending program is not defined correctly in the Processing Program Table, DFHPPT. Or the program has been link-edited incorrectly.
- In case of an abend ABMB, OLPD abends with an abend ASRA which brings down CICS TS, retrieving additional abend information.
ABMB abends are issued by different routines not fitting to the single typre error analysis done by OLPD.
|
PQ45663
2001/03/06 |
UQ51988 |
RELIEF OF DSA STORAGE BELOW THE LINE FOR PANEL HIERARCHY LIST IN IUI
For each IUI user, about 4 K of storage for the user status record and the panel hierarchy list (PDL) are required.
The PDL is allocated for each user, even in case the user does not have a selection panel specified as initial panel.
Users having an application as initial selection do not have a need for a PDL, the related storage can be freed immediately.
This should save about 1K of storage below the line for each user accessing an application directly after signon. |
 |
APAR
Date |
PTF |
Contents |
PQ46308
2001/03/05 |
UQ51940
UQ51939 |
IESINWMOB INCORROUT PROBLEM
- IESINWMOB(IUI Path:3-8-1-1) to display file list in host transfer file is scrumbled.
- SRV$FS02 on German system gets FO24 abend.
- SRV$FS03 on German system gets FO24 abend.
|
PQ43503
2001/01/19 |
UQ50172
UQ50167
UQ50166
UQ50165 |
NLSVERUP MEMBER INCORRECT FOR ALL LANGUAGES
- The selective restore in step DTRFSU22 in case of a release upgrade from 2.4.x to 2.5.x will fail because the restore instructions in member NLSVERUP are not in alphabetical order.
- Support of the new CICS TS domains: BR - 3270 Bridge,
DH - Document Handler Domain, SO - Sockets Domain and WB - WEB Support domain in the dump management dialog.
|
PQ44269
2001/01/19 |
UQ50164 |
WEB ERROR PROGRAM, DUMP DIALOG - SUPPORT OF NEW CICS TS DOMAINS
- Provide a skeleton to compile the so called WEB error program DFHWBEP for the CICS TS WB domain.
- Support of the new CICS TS domains in the dump management dialog.
- Add a new REXX procedure to migrate CSD definitions from CICS/VSE to DTSEXTXN macro format.
|
PQ43137
2000/11/17 |
UQ48770 |
ASRA IN OLPD ROUTINE IESOPIA OFFSET X'000009CA'
- After an ASRA abend in a user program, OLPD exit routine IESOPIA got also an ASRA at offset X'000009CA'. Exploiting the operands of the failing user program, the first operand's base address pointed outside the CICS partition boundaries leading to a segment translation error.
- Procedure IESWAITR does not work properly due to truncation in column 72 and missing End statement.
- SKIOCPN should use the most common program for IOCP generation IZPIOCP, moreover, it should mention the old and new program names for old and new CPUs.
|
PQ42737
2000/10/30 |
UQ48300 |
REMOTE TRANSACTIONS CAUSE MESSAGE PROGRAM ' ' FOR TRANSACTION XXXX NOT DEFINED
For a remote transaction NATO, message "Program ' ' for transaction NATO is not available." is issued.
On CICS/VSE 2.3 when done via DFHPCT type=remote specification forces the program to "DFHCRP".
So on VSE 2.3 there was a program specified.
On CICS TS, with RDO the program name is not required when an remote system is specified. (If a program is specified it is ignored.)
|
PQ41225
2000/09/15 |
UQ47022 |
SEVERAL PROBLEMS WITH VSE/ESA 2.5 - PTF1
- SVA size was set to PSIZE=(650K,6M),SDL=700,GETVIS=(768K,6M), PSIZE should be a multiple of 4K, PSIZE changed to 652K.
- Delete jobs for HLASM and TCP/IP comments.
- CICS Listener problems.
- User CICSUSER should have a blank OPID, Info APAR II12446
- OLPD fails see APAR PQ41186
- FSU missing PAUSE statement.
- Installation on FBA with 9336-10, VSAMDEFS requires about 2000 blocks more than 920115, VTOC must not be located at the end of the volume.
|
| Comp. ID |
CLC |
Description |
| 5686-066-01 |
55C |
VSE/SP Unique Code |
| 5686-066-02 |
55H |
VSE/ESA MRI Spanish |
| 5686-066-02 |
55E |
VSE/ESA MRI Japanese |
| 5686-066-02 |
55D |
VSE/ESA MRI English |
| 5686-066-02 |
55A |
VSE/ESA MRI German |
| 5686-066-10 |
55C |
VSE/ICCF |
| |
 |

 |
Easy ways to get the answers you need. |

 |
 |
 |
|