Latest VSE/Interactive Interface and VSE/ICCF 8.3 APARs for z/VSE V4.3

Last update: Jan 22, 2014

APAR
Date
PTF Contents
PI09239
2014/01/22
UI14203-02C DFH0STAT UPDATE AFTER PM69135 ENHANCEMENTS
After PM69135, DFHOSTAT in ICCF library 59 needs to be updated.
PM80032
2013/01/13
UK90780-02C FLOOD OF MSG EZY1305E FROM EZACIC02
The Listener received an exception event on this connection other than the event showing a successful take socket was issued by the server. The problem occurs when socket 0 has been given (with GIVESOCKET)to transaction WCOM and WCOM has successfully taken this socket (with TAKESOCKET). Now the CICS Listener is postedwith the SELECTEX Exception bit for socket 0 and is about to clean up its control block for socket 0. But this control block is already cleared out.
PM63377
2012/05/01
UK78405-02E BASIC STARTUP DISPLAYS CICS SIGN ON PANEL INSTEAD OF JAPANESE DBCS PANEL
Default terminals used during basic startup and initial installation are not defined correctly.
PM60783
2012/03/30
UK77261-02C ESM NOT CHECKED CORRECTLY IN SECURITY DIALOGS AND IN USER PROFILE MAINTENANCE
If customer uses an external security manager (ESM), the user user profile maintenance dialog may fail when transferring control to the MAINTAIN SECURITY PROFILES dialog for group maintenance. In addition the security dialog does not check correctly for an ESM.
Customer got UPMU abend defining a user. The abend was caused by a definition error in CSD. Customer uses an ESM. This fix will improve handling of attached dialogs BSM Group Maintenance and also the other BSM security dialogs if an ESM is used.
PM53762
2011/12/12
UK74547-02C MSGBST120I INSUFFICIENT ACCESS AUTHORITY RUNNING REXDFHDU
If CEMT transaction is removed from default security group01 or default user CICSUSER is not authorized for CEMT, running REXX procedure REXDFHDU e.g. in PRTDUMPA job will fail with
BST120I USER(CICSUSER)
BST120I   CEMT CL(TCICSTRN)
BST120I   INSUFFICIENT ACCESS AUTHORITY
BST120I   FROM CEMT
BST120I   ACCESS INTENT(READ)
          ACCESS ALLOWED(NONE)
in the related CICS partition. Modify procedure REXDFHDU - change all occurrences of MYREXX to REXX.
PM53774
2011/12/12
UK74548-02D
UK74549-02E
MSGBST120I INSUFFICIENT ACCESS AUTHORITY RUNNING HEALTH CHECKER
If CEMT transaction is removed from default security group01 or default user CICSUSER is not authorized for CEMT, running Health Checker will fail with messages
BST120I USER(CICSUSER)
BST120I   CEMT CL(TCICSTRN)
BST120I   INSUFFICIENT ACCESS AUTHORITY
BST120I   FROM CEMT
BST120I   ACCESS INTENT(READ)
          ACCESS ALLOWED(NONE)
in the related CICS partition. IESZTCT includes a list of terminals associated with userid CNSL. This userid should be added to terminals CO01-CO20.
PM52199
2011/11/21
UK73974-02C DURING MSHP RETRACE OR DEFRAG RECEIVED MSGM063I
Customer received msgM063I during a MSHP RETRACE job. Running a MSHP DEFRAG job returns also msgM063I. Using a large static partition (32M) gave the same error. Using // EXEC MSHP,SIZE=2M permits to bypass the problem.
PM51052
2011/11/02
UK73246-02C DTRIATTN HANGS IN CERTAIN CASES, UPGRADE DFH0STAT, ESCAPE TRANIDONLY
PM46594
2011/09/14
UK71603-02D
UK71604-02E
GARBAGE DATA ON DISPLAY ACTIVITY PANEL IF DIRECT USER
Display activity panels was defined as initial application for user CPUACT - a so called direct user. After some time, there was garbage in the title line like:
IESADMDA URATION 00/00/11
This seems to be caused by field USPFPASO in User Status Record. This field is used to hold any user data shown on previous panel. Since this is a direct user, this information should not get retrieved at all.
PM44072
2011/08/26
UK71176-02C NEW TCP/IP PHASES SOCKET00-99 NOT DELETED WITH DELTCPIP JOB
DELTCPIP should delete new phases SOCKET00-99
PM43213
2011/07/11
UK69528-02C IND$FILE TRANSFER WITH DBCS TERMINAL DOES NOT ALLOW OPTIONS LRECL=80 BINARY TRANSFERRING TO A VSE LIBRARY
SEND PTFFILE.BIN A:PTFFILE Z (FILE=LIB L=PRD1 S=BASED LRECL=80 BINARY gets message INW0006I BINARY is INVALID or CONFLICTING OPTION if send command is issued by a DBCS terminal. This works on a single byte mode terminal. DBCS uses APVUfile instead of IND$FILE
PM38872
2011/05/23
UK67948-02C IMVERUP DOES NOT LIST MEMBER EDCTCPMC AND THEREFORE IT IS NOT RESTORED DURING FSU
Member EDCTCPMC is not restored into ICCF library 62 during FSU.
PM31319
2011/03/01
UK65178-02C ABEND UPMU RUNNING USER PROFILE MAINTENANCE ON CICS2
Message IESA1068with code '02' if altering a user running user profile maintenance on CICS2 (PRODCICS).
Abend UPMU - message (1068) is issued if defining or changing a user while ICCF is not available (permanent or temporarily) or if defining user is a non ICCF user (e.g. more than 4 character userid).
PM33291
2011/02/23
UK65064-02C MESSAGE INDICATOR BLINKING AND NOT RESET AFTER REDISPLAY
If only a few lines left on the screen, entering a command like MAP followed by PF7 and then PF3 end in the fact that the MESSAGE indicator is blinking and cannot be reset. Only ending the console (PF3) resets the console correctly.
PM32840
2011/02/21
UK64937-02C UPPERCASE TRANSLATION FOR SPECIAL CHARACTERS 'BA'X AND 'BB'X NOT DISPLAYABLE.
Special characters 'BA'x and 'BB'x cannot be displayed on Japanese terminal. Uppercase translation should reflect this to characters and translate to '4D'x resp. '5D'x.
PM30110
2011/02/17
UK63804-02C ADD OPTION NOT WORKING ON UNIDENTIFIED DEVICE LIST IF ADDING BY DEVICE TYPE
On the unidentified device list right after initial installation it is not possible to enter the related device type directly. If selecting by the device list entering blank or a question mark, selection is possible. Minor logic problem in FSU step DTRFSU15 removing generation part.
PM27259
2010/12/09
UK62686-02C UPPERCASE TRANSLATION OT OME MESSAGES WITH DBCS MESSAGES NOT WORKING CORRECTLY
Online message explanation garbled in case of uppercase translation in IESxDEF resp. IJBxDEF.

 

VSE/Interactive Interface and VSE/ICCF 8.3 components

Comp. ID CLC Description
5686-CF8-01 02C VSE/SP Unique Code
5686-CF8-02 02E z/VSE MRI Japanese
5686-CF8-02 02D z/VSE MRI English
5686-CF8-10 02C VSE/ICCF