| Models | M05 | M10 |
|---|---|---|
| Processor Core Types: CP1/IFL2/ICF/zAAP3/zIIP1/Std SAP/Add'l SAP/Spares/zBX | ||
| Minimum4 | 0 / 0 / 0 / 0 / 0 / 2 / 0 / 0 / 0 | 0 / 0 / 0 / 0 / 0 / 2 / 0 / 0 / 0 |
| Maximum | 5 / 5 / 5 / 2 / 2 / 2 / 2 / 0 / 1 | 5 / 10 / 10 / 5 / 5 / 2 / 2 / 2 / 1 |
| IC maximum | 32 | 32 |
|---|---|---|
| Maximum # external coupling links | 565 | 725 |
| ISC-3 maximum6 | 48 | 48 |
| 12x InfiniBand maximum | 8 | 16 |
| 1x InfiniBand maximum | 16 | 32 |
| CHPID maximum | 128 | 128 |
| Channels: ESCON/FICON Express 8S/FICON Express8/FICON Express4/OSA-Express4S/OSA-Express3/OSA-Express2 | ||
| Minimum: | 0 / 0 / 0 / 0 / 0 / 0 | 0 / 0 / 0 / 0 / 0 / 0 |
| Maximum: | 240 / 128 / 64 / 64 / 96 / 64 / 32 | 240 / 128 / 64 / 64 / 96 / 64 / 32 |
| HiperSockets™ | Up to 32 | Up to 32 |
| Crypto Express3 | Minimum order is two features, one thereafter; maximum is eight features (8/16 PCIe adapters) |
|---|
| Minimum | 8 GB (plus 8 GB for HSA) | 16 GB (plus 8 GB for HSA) |
|---|---|---|
| Maximum | 120 GB (plus 8 GB for HSA) | 248 GB (plus 8 GB for HSA) |
| Max Weight (Base/w Batteries/w Batteries & Overhead I/O Cabling/w Batteries, Overhead I/O & Balanced Power) | 1802 lbs/2028 lbs/2123 lbs/2235 lbs | 2064 lbs/2290 lbs/2385 lbs/2497 lbs) |
|---|---|---|
| Footprint | 30 in. W x 50 in. D or 0.97 sq meters (10.42 sq ft) | 30 in. W x 50 in. D or 0.97 sq meters (10.42 sq ft) |
| Service | 36 in. W x 140 in. D or 3.16 sq meters (30.38 sq ft) | 36 in. W x 140 in. D or 3.16 sq meters (30.38 sq ft) |
| Product Dimensions (W × D × H)8 | 30.87 x 62 x 79.26 in (784 x 1575 x 2013 mm)8 | 30.87 x 62 x 79.26 in (784 x 1575 x 2013 mm)8 |
| Input 28° C and altitude 3000 ft, 28° C and altitude 3000 ft | 4.526 KW, 5.256 KW | 6.309 KW, 7.364 KW |
| Heat 28° C and altitude 3000 ft, 28° C and altitude 3000 ft | 15.4 KBTU/hr, 17.9 KBTU/hr | 21.5 KBTU/hr, 25.1 KBTU/hr |
| Air Flow Nominal9 | 1100 CFM | 1230 CFM |
| Upgradeable from IBM System z10™ Business Class (z10 BC) and IBM System z9® Business Class (z9 BC) |
|---|
| Upgradeable within the Model |
| Upgradeable within the z114 family (M05 to M10)10 |
| M10 upgradeable to the zEnteprise 196 (machine type 2817) M15 |
| z/OS11 | z/OS V1.11, 1.12, 1.13 or higherz/OS V1.10, V1.9 and V1.8 Lifecycle ExtensionzBX Ensemble support: z/OS V1.10 or higher |
|---|---|
| z/VM | z/VM 5.4 and subsequent releases. z/VM 6.1 for zBX support |
| Linux on System z | Red Hat Enterprise Linux (RHEL) 5 and subsequent releases, SUSE Linux Enterprise Server (SLES) 10 (SP4)and SLES 11 SP2 |
| z/VSE® | z/VSE V4.2 and subsequent releases |
| z/TPF | z/TPF 1.1 |
| AIX® (on BladeCenter PS701 Express blades installed in IBM zEnterprise BladeCenter® Extension) | AIX 5.3, AIX 6.1 and AIX 7.1 and subsequent releases and PowerVM™ Enterprise Edition |
| Linux on System x (on IBM BladeCenter HX5 blades installed in zBX) | Red Hat RHEL 5.5, 5.6, 6.0 and SLES 10 (SP4), and SLES 11 SP1 |
| Microsoft Windows (on IBM BladeCenter HX5 blades installed in zBX) | Microsoft Windows Server 2008 R2 and Microsoft Windows Server 2008 (SP2) (Datacenter Edition recommended) – 64-bit only |
| IBM Smart Analytics Optimizer V1,112 | 5 solution sizes: 7, 14, 28, 42, 56 | |
|---|---|---|
| IBM WebSphere DataPower Integration Appliance XI50 for zEnterprise | Minimum: 0 | Maximum: 2813 |
| IBM BladeCenter PS701 Express blades | Minimum: 0 | Maximum: 11213 |
| IBM BladeCenter HX5 blade | Minimum: 0 | Maximum: 5613 |
1 No CP is required if ordering an IFL or ICF only server.
2 No IFL is required unless ordering an IFL only server.
3 If ordering a zAAP or a zIIP, one or more general purpose processor (CP) per the specialty engine is required. One CP can satisfy the requirement for either or both of the specialty engines.
4 Must be configured with a minimum of one CP, IFL or ICF.
5 The maximum external links is obtained with a combination of ISC-3 and 1x Infiiband links.
6 ISC-3 Peer mode only.
7 Can be acquired in increments of 8 or 32 GB; Excludes the standard fixed size of 8 GB HSA which is separately managed; RAIM standard.
8 Optional overhead I/O cabling feature adds 6 in. to the width.
9 Airflow is designed to increase as the local ambient room temperature increases. Nominal airflow assumes 77°F ambient.
10 Upgrading from the M05 to the M10 or from the M10 to M15 will require a planned outage.
11 z/OS V 1.10 is the minimum level required to support an ensemble.
12 On November 1, 2011, IBM Smart Analytics Optimizer was withdrawn from marketing for new build and MES zBX. It has been replaced with IBM DB2 Analytics Accelerator for z/OS (IDAA), a new workload optimized, appliance add-on that attaches to the zEnterprise System.
13 The BladeCenter PS701 Express and BladeCenter HX5 blades and DataPower XI50z can share the same BladeCenter chassis—note that DataPower XI50z blades are “doublewide” and use two slots. They can be mixed in the same zBX with IBM Smart Analytics Optimizer for DB2 for z/OS V1.1 blades—but not in the same BladeCenter Chassis. Total zBX capacity cannot exceed 112 total blades.