Skip to main content
Skip to main content



Rack power configurator

Attention:
A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document.

IBM Uninterruptable Power Supplies (EMEA)

Order a UPS Product... Plus a Line Cord
Option part number Description Option part number Description Power source
 
IBM Tower UPS (2130-TU1)        
2130R4X IBM UPS1000THV select from the list of line cords below:
2130R6X IBM UPS1500THV
  Line Cords:
39Y7917* 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord single-phase 10A/230V
39Y7918* 2.8m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord single-phase 10A/230V
39Y7920* 2.8m, 10A/230V, C13 to SI 32 (Israel) Line Cord single-phase 10A/230V
39Y7921 2.8m, 10A/230V, C13 to CEI 23-16 (Italy) Line Cord single-phase 10A/230V
39Y7922* 2.8m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord single-phase 10A/230V
39Y7919* 2.8m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord single-phase 10A/230V
39Y7923* 2.8m, 10A/230V, C13 to BS 1363/A (UK) Line Cord single-phase 10A/230V
  Specifications  
Version: 750VA 1000VA 1500VA
Outlets: six IEC C13 eight IEC C13 eight IEC C13
Power Capacity: 500W 670W 980W
Power Limit per Outlet: 10A 10A 10A
Power Limit per UPS: 3.4 4.5 6.8
Power Monitoring: Yes Yes Yes
Battery Expansion: No No No
 
 
IBM Rack UPS (2130-RU1)        
21301RX* IBM UPS3000LV attached line cord: 12ft NEMA L5-30P
40K9620* IBM UPS Extend Run Battery Pack (2U)
  Specifications  
Outlets: six NEMA 5-15R one NEMA L5-30R
Power Capacity: 2700W @ 120V
Power Limit per Outlet: 10A 10A
Grouping: two 5-15R two 5-15R + L5-30R
Power Limit per Group: 20A 20A
Power Limit per UPS: 24A
Power Monitoring: Yes
Battery Expansion: Yes, four 2U units max (P/N 40K9620)
 
21302RX* IBM UPS3000HV select from the list of Line Cords below:
  Line Cords:
40K9766 4.3m, 16A/230V, C19 to CEE7-VII (Europe) Line Cord single-phase 16A/230V
40K9769 4.3m, 16A/230V, C19 to IEC 309-P+N+G (Den/Sws) Line Cord single-phase 16A/230V
40K9771 4.3m, 16A/230V, C19 to SI 32 (Israel) Line Cord single-phase 16A/230V
40K9768 4.3m, 16A/230V, C19 to CEI 23-16 (Italy) Line Cord single-phase 16A/230V
40K9770 4.3m, 16A/230V, C19 to SABS 164 (South Africa) Line Cord single-phase 16A/230V
40K9767 4.3m, 13A/230V, C19 to BS 1363/A w/13A fuse (UK) Line Cord single-phase 16A/230V
40K9620* IBM UPS Extend Run Battery Pack (2U)
  Specifications  
Outlets: nine IEC C13 one IEC C19
Power Capacity: 2700W @ 208V
Power Limit per Outlet: 10A 16A
Grouping: 2x(three C13) 1x(three C13 + one C19)
Power Limit per Group: 20A 20A
Power Limit per UPS: 16A
Power Monitoring: Yes
Battery Expansion: Yes, four 2U units max (P/N 40K9620)
 
21303RX IBM UPS7500XHV requires electrician to connect to source power circuit (with 50A circuit breaker (typical))
39Y8857 IBM UPS Extend Run Battery Pack (3U)
  Specifications  
Version: single phase 3-phase
Outlets: four IEC C19 (using Rack PDUs: 28 IEC C13)
Power Capacity: 6000W @ 200V 6000W @ 200V
Power Limit per Outlet: 15A 15A
Power Limit per UPS: 38A 38A
Power Monitoring: Yes Yes
Battery Expansion: Yes, four 3U units max
(P/N 39Y8857)
 
21304RX IBM UPS10000XHV requires electrician to connect to source power circuit (with 63A circuit breaker (typical))
39Y8857 IBM UPS Extend Run Battery Pack (3U)
  Specifications  
Version: single phase 3-phase
Outlets: four IEC C19 (using Rack PDUs: 28 IEC C13)
Power Capacity: 8000W @ 200V 8000W @ 200V
Power Limit per Outlet: 15A 15A
Power Limit per UPS: 50A 50A
Power Monitoring: Yes Yes
Battery Expansion: Yes, four 3U units max
(P/N 39Y8857)
 

* IBM has withdrawn this product from marketing.

Note:

This table describes the IBM System x family of Uninterruptible Power Supply (UPS) products. Feature Codes are used with the eConfig Product and Solution Configurator.



         May 14, 2012