Rack power configurator
| A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document. |
Tab navigation
- Overview- selected tab,
- US & Canada
- EMEA
- Asia Pacific
- Latin America
Tab navigation
Attention:UPS Data for Latin America and Asia Pacific will be added in a later COG release.
Rack Power Products:
IBM Distributed Power Interconnect (DPI) Power Distribution Units
(PDU)
- DPI 100-127v NEMA PDU
- DPI Universal Rack PDU
- DPI Single-phase Front-end PDUs
- DPI Single-phase Enterprise PDUs and PDU+ with Monitoring
- DPI Three-phase Enterprise PDUs and PDU+ with Monitoring
- IBM Single-phase Switched and Monitored PDU
- IBM Three-phase Switched and Monitored PDU
- 0U Single-phase PDUs
- 0U Three-phase PDUs
IBM 7176 Ultra Density Enterprise Power Distribution Units (PDUs)
- Ultra Density Enterprise PDU
- Ultra Density Enterprise PDU+ with Monitoring
IBM Uninterruptable Power Supplies (UPS)
- UPS3000LV*
- UPS3000HV*
- UPS5000XHV
- UPS7500XHV
- UPS10000XHV
- 5395 1500 LV
- 5395 2200 LV
- 5395 3000 LV
- 5395 3000 HV
- 5395 6000 HV
Tower Power Products:
- 5396 1000 LV
- 5396 1500 HV
Power Outlets
IBM Power Distribution Unit
| Outlets | C19 | C13 | 5-15R |
|---|---|---|---|
| NEMA PDU | 0 | 0 | 6 |
| Rack PDU | 0 | 7 | 0 |
| Front-end PDU | 3 | 0 | 0 |
| Enterprise C13 PDU | 0 | 12 | 0 |
| Enterprise C19 PDU | 6 | 0 | 0 |
| Enterprise C13 PDU+ | 0 | 12 | 0 |
| Enterprise C19/C13 PDU+ | 9 | 3 | 0 |
| Switched and Monitored C13 | 0 | 12 | 0 |
| Switched and Monitored C19/C13 | 9 | 3 | 0 |
| 0U PDUs - Basic 24 C13 | 0 | 24 | 0 |
| 0U PDUs - Basic 12 C13/12 C19 | 12 | 12 | 0 |
| Ultra Density Enterprise C19/C13 PDU | 9 | 3 | 0 |
| Ultra Density Enterprise C19/C13 PDU+ | 9 | 3 | 0 |
IBM Uninterruptible Power Supplies
| Native ports | ||||||||
| Outlets | C19 | C13 | 5-15R | 5-20R | 5-30R | L5-20R | L6-20R | L6-30R |
|---|---|---|---|---|---|---|---|---|
| IBM 3000LV* | 0 | 0 | 6 | 0 | 1 | 0 | 0 | 0 |
| IBM 3000HV* | 1 | 9 | 0 | 0 | 0 | 0 | 0 | 0 |
| IBM 5000XHV | 2 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | IBM 7500XHV | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| IBM 10000XHV | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 1500 LV | 0 | 2 | 4 | 0 | 0 | 0 | 0 | 0 |
| 5395 2200 LV | 2 | 2 | 0 | 6 | 0 | 0 | 0 | 0 |
| 5395 3000 LV | 2 | 2 | 0 | 2 | 0 | 1 | 0 | 0 |
| 5395 3000 HV | 2 | 2 | 0 | 0 | 0 | 0 | 2 | 0 |
| 5395 6000 HV | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 2 |
| 5396 1000 LV | 0 | 0 | 8 | 0 | 0 | 0 | 0 | 0 |
| 5396 1000 HV | 0 | 8 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5396 1500 LV(100V) | 0 | 0 | 0 | 8 | 0 | 0 | 0 | 0 |
| 5396 1500 LV(120V) | 0 | 0 | 8 | 0 | 0 | 0 | 0 | 0 |
| 5396 1500 HV | 0 | 8 | 0 | 0 | 0 | 0 | 0 | 0 |
| Total Ports Using PDUs | ||||||||||
| UPS | PDU Type | # PDUs | C19 | C13 | 5-15R | 5-20R | 5-30R | L5-20R | L6-20R | L6-30R |
|---|---|---|---|---|---|---|---|---|---|---|
| 2130 7500XHV | Rack | 4 | 0 | 28 | 0 | 0 | 0 | 0 | 0 | 0 |
| 2130 10000XHV | Rack | 4 | 0 | 28 | 0 | 0 | 0 | 0 | 0 | 0 |
| 2419 5000 HV | Rack | 2 | 0 | 22 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 1500 LV | None | 0 | 0 | 2 | 4 | 0 | 0 | 0 | 0 | 0 |
| 5395 2200 LV | Rack | 2 | 0 | 16 | 0 | 6 | 0 | 0 | 0 | 0 |
| 5395 3000 LV | Rack | 2 | 0 | 16 | 0 | 2 | 0 | 1 | 0 | 0 |
| 5395 3000 HV | Rack | 2 | 0 | 16 | 0 | 0 | 0 | 0 | 2 | 0 |
| 5395 6000 HV | Rack | 2 | 0 | 28 | 0 | 0 | 0 | 0 | 0 | 2 |
| 5395 6000 HV | FE | 2 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 2 |
| 5395 6000 HV | Enterprise C13 | 2 | 4 | 24 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | Enterprise C19 | 2 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | Enterprise+ C13 | 2 | 4 | 24 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | Switch&Monitor C13 | 2 | 4 | 24 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | Switch&Monitor Combo | 2 | 22 | 6 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | 0U C13 | 2 | 4 | 48 | 0 | 0 | 0 | 0 | 0 | 0 |
| 5395 6000 HV | 0U Combo | 2 | 28 | 24 | 0 | 0 | 0 | 0 | 0 | 0 |
* IBM has withdrawn this product from marketing.
Notes: (reference the following graphic):
- Each device usually comes with a power cord. The PDU requires the
power cord to have an IEC 320-C14 plug. Order 39Y7932(14ft) if
appropriate cord is not provided with the device. - Each PDU comes with or requires a country-specific power cord.
- P/S = Power Supply
- One 2m internal rack power cable provided with DPI Rack PDU.
- Devices with C20 power inlets require C19 to C20 power cords.
- Option 39Y7938 provides a C13 to C20 power cord to attach normal
devices with C14 power inlets directly to Front-end, Enterprise C19,
or High Density PDUs. - UPS uses a country-specific line cord or has a terminal block
requiring an electrician to connect to power source. - Line cord provided with Front-end PDU.
Attention:Â Customers are responsible for providing a dedicated circuit for each line cord protected with an appropriate circuit breaker.