| Option part number |
Description |
Power cord description |
Power source |
| |
| DPI Universal Rack PDU (includes 2m C19/C20 rack power cable) |
| any of the following |
DPI Universal Rack PDU module without line cord |
rack power cable: 2m C19/C20 |
another PDU or UPS (100-250V) |
| 39Y8952 |
DPI Universal Rack PDU (Europe) |
line cord: 4.3m CEE7-VII |
single-phase 16A/230V |
| 39Y8953 |
DPI Universal Rack PDU (Den/Sws) |
line cord: 4.3m IEC 309 P+N+G |
single-phase 16A/230V |
| 39Y8954 |
DPI Universal Rack PDU (Israel) |
line cord: 4.3m SI 32 |
single-phase 16A/230V |
| 39Y8955 |
DPI Universal Rack PDU (Italy) |
line cord: 4.3m CEI 23-16 |
single-phase 16A/230V |
| 39Y8956 |
DPI Universal Rack PDU (South Africa) |
line cord: 4.3m SABS 164 |
single-phase 16A/230V |
| 39Y8957 |
DPI Universal Rack PDU (UK) |
line cord: 4.3m BS 1363/A |
single-phase 13A/230V |
| 39Y8951 |
DPI Universal Rack PDU (US) |
line cord: 4.3m NEMA L5-20P (detachable) |
single-phase 20A/120V 60Hz |
| line cord: 4.3 NEMA L6-20P (detachable) |
single-phase 20A/208V 60Hz |
| |
Specifications |
|
| Version: |
to PDU or UPS |
16A/230V |
UK |
Saudi Arabia (US LV) |
| Outlets: |
seven IEC C-13 |
seven IEC C-13 |
seven IEC C-13 |
seven IEC C-13 |
| Power Capacity: |
3000W @ 200V |
3450W @ 230V |
2990W @ 230V |
1800W @ 120V |
| Power Limit per Outlet: |
10A |
10A |
10A |
10A |
| Power Limit per PDU: |
15A |
15A |
13A |
15A |
| Power Monitoring: |
No |
No |
No |
No |
| |
| |
| DPI Front end PDU |
| 39Y8938 |
DPI Single-phase 30A/120V Front-end PDU (US) |
line cord: 2.5m NEMA L5-30P |
single-phase 30A/120V |
| 39Y8934 |
DPI Single-phase 32A/230V Front-end PDU high voltage (non US) |
line cord: 2.5m IEC 309 P+N+G |
single-phase 32A/220-240V |
| 39Y8935 |
DPI Single-phase 63A/230V Front-end PDU high voltage (non US) |
line cord: 2.5m IEC 309 P+N+G |
single-phase 63A/220-240V |
| |
Specifications |
|
| Version: |
30A/120V |
32A/220-240V |
63A/220-240V |
| Outlets: |
three IEC C19 |
three IEC C19 |
three IEC C19 |
| Power Capacity: |
2880W @ 120V |
7360W @ 230V |
14490W @ 230V |
| Power Limit per Outlet: |
16A |
16A |
16A |
| Power Limit per PDU: |
24A |
32A |
63A |
| Power Monitoring: |
No |
No |
No |
| |
| |
| DPI High Density PDU |
| - |
- |
- |
- |
| |
| DPI 100-127V NEMA PDU |
| 39Y8905 |
DPI 100-127V NEMA PDU |
attached line cord: 9ft NEMA L5-15P |
single-phase 15A/100-127V 60Hz |
| |
Specifications |
|
| Version: |
Saudi Arabia (US LV) |
| Outlets: |
six NEMA 5-15R |
| Power Capacity: |
1440W @ 120V |
| Power Limit per Outlet: |
10A |
| Power Limit per PDU: |
12A |
| Power Monitoring: |
No |
| |
| Note: |
This table describes some of the IBM Distributed Power Interconnect products, a family of power distribution
units (PDUs). See the table DPI Enterprise Power Distribution Units for more options. |