| A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document. |
Tab navigation
- Overview
- US & Canada
- EMEA
- Asia Pacific
- Latin America- selected tab,
IBM 7176 Ultra Density Enterprise Power Distribution Units (Latin America)
NOTE: Also see the US/Canada section.
| Order a PDU Module ... | Plus a Line Cord | ||||||||
| MTM | PDU Module Description | SEO / Option Part Number | Power Cord Description | Power Source | |||||
|---|---|---|---|---|---|---|---|---|---|
| IBM Ultra Density Enterprise PDU and PDU+ | |||||||||
| 7176 - PN1 IBM Ultra Density Enterprise C19/C13 PDU | |||||||||
| 71762NX | IBM Ultra Density Enterprise C19/C13 PDU Module (WW) | + | 40K9612 | 4.3m, 32A/230V, IEC 309 P+N+G (non-US) Line Cord | single-phase 32A/220-240V | ||||
| + | 40K9613 | 4.3m, 63A/230V, IEC 309 P+N+G (non-US) Line Cord | single-phase 63A/220-240V | ||||||
| + | 40K9611 | 4.3m, 32A/380-415V, IEC 309 3P+N+G (non-US) Line Cord | three-phase wye 32A/380-415V | ||||||
| Specifications: | |||||||||
| Version: | 32A/220-240V | 63A/220-240V | 3-phase | ||||||
| Outlets: | nine IEC C19 | three IEC C13 | nine IEC C19 | three IEC C13 | nine IEC C19 | three IEC C13 | |||
| Power Capacity: | 7360W @ 230V | 14490W @ 230V | 22080W @ 230V | ||||||
| Power Limits - | |||||||||
| per outlet: | 16A | 10A | 16A | 10A | 16A | 10A | |||
| grouping: | pairing of one 10A with one 16A | pairing of one 10A with one 16A | each phase has two 16A + one 10A | ||||||
| per group: | 20A | 20A | 32A | ||||||
| per PDU: | 32A | 63A | -- | ||||||
| Power Monitoring: | No | No | No | ||||||
| 7176 - PM1 IBM IBM Ultra Density Enterprise C19/C13 PDU+ | |||||||||
| 71762MX* | IBM Ultra Density Enterprise C19/C13 PDU+ Module (WW) | + | 40K9612 | 4.3m, 32A/230V, IEC 309 P+N+G (non-US) Line Cord | single-phase 32A/220-240V | ||||
| + | 40K9613 | 4.3m, 63A/230V, IEC 309 P+N+G (non-US) Line Cord | single-phase 63A/220-240V | ||||||
| + | 40K9611 | 4.3m, 32A/380-415V, IEC 309 3P+N+G (non-US) Line Cord | three-phase wye 32A/380-415V | ||||||
| Specifications: | |||||||||
| Version: | 32A/220-240V | 63A/220-240V | 3-phase | ||||||
| Outlets: | nine IEC C19 | three IEC C13 | nine IEC C19 | three IEC C13 | nine IEC C19 | three IEC C13 | |||
| Power Capacity: | 7360W @ 230V | 14490W @ 230V | 22080W @ 230V | ||||||
| Power Limits - | |||||||||
| per outlet: | 16A | 10A | 16A | 10A | 16A | 10A | |||
| grouping: | pairing of one 10A with one 16A | pairing of one 10A with one 16A | each phase has two 16A + one 10A | ||||||
| per group: | 20A | 20A | 32A | ||||||
| per PDU: | 32A | 63A | -- | ||||||
| Power Monitoring: | Yes | Yes | Yes | ||||||
Notes:
- This table describes some of the IBM power distribution unit products available for use with System x and BladeCenter servers.
- For C19/C13 PDUs, each C19 outlet has a 20A circuit breaker. Each C13 shares one of the C19 circuit breakers.
- The combined load on the C13 and associated C19 must not exceed 20A.
- These PDUs carry their own Machine Type number.
- When ordering Line Cords as separate options, use the Single Entity Offering (SEO) order part number.
- For integrated rack-based solutions, Feature Codes are used to order the Line Cords as features of the PDUs.