Attention:

A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document.

Tab navigation

Tab navigation

SBB number Option number Feature code Description Connection
type from
Connection
type to
# of
Drops
Connects
from
Connects
to
32R1938 32R1937 4362 IBM CX4 1.5 Meter Cable CX4 Connector CX4 Connector 1 10Gb ESM CX4 Port Another Nortel 10Gb ESM or external 10Gb switch with CX4 ports.
39Y9173 39Y9171 4364 IBM BladeCenter Optical Pass-thru Module SC Cable (1.5) Multiport Optical SC Duplex Optical Connections 4 OPM switch SAN
39Y9175 39Y9172* 4365 IBM BladeCenter Optical Pass-thru Module LC Cable (1.5) Multiport Optical LC Duplex Optical Connections 4 OPM switch SAN
39Y9331 39Y9170 4366 IBM BladeCenter Copper Pass-thru Module Cable Multiport Copper CAT 5E Copper Connections 5 CPM switch Network
32R1942 - 4363 IBM CX4 3.0 Meter Cable CX4 Connector CX4 Connector 1 10Gb ESM CX4 Port Another Nortel 10Gb ESM or external 10Gb switch with CX4 ports.
- 39Y7931 - Power Cable - C13 / NEMA 5-15P 14ft - - - - -
- 39Y8966 - IBM USB to PS/2 Converter Cable - - - - -
- 32R1941 - CX4 - 3.0 meter Cable for IBM BladeCenter - - - - -

Notes:

  1. Provides five copper connections between the copper pass-thru module (CPM) and an external gigabit Ethernet environment. A maximum of 14 connections per CPM is supported. One CPM cable ships with the CPM option. Two additional cables can be installed.
  2. Utilizing pass-thru technology will disable serial over LAN concurrent KVM capabilities.

Figure 1. IBM BladeCenter Copper Pass-thru Module Cable (3.1 m)

Figure  1. IBM BladeCenter Copper Pass-thru Module Cable (3.1 m)

Click image to enlarge

IBM BladeCenter Copper Pass-thru Module Cable (3.1 m)

Figure  1. IBM BladeCenter Copper Pass-thru Module Cable (3.1 m)

Note:

  1. This IBM BladeCenter option provides connection between the
    copper pass-thru module and an external environment. The cable
    allows up to five copper connections to blade servers. One 3.1 m
    (9.4 ft)cable is included with each copper pass-thru module.

Figure 2. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5 m)

Figure  2. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5 m)

Click image to enlarge

IBM BladeCenter Optical Pass-thru Module SC Cable (1.5 m)

Figure  2. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5 m)

Note:

  1. The 1.5 m cable above provides four SC connections between the
    Optical Pass-thru Module and an external environment.

Figure 3. IBM CX4 1.5 or 3-meter Cable for IBM BladeCenter
(connector color is Gray)


Figure  3. IBM CX4 1.5 or 3-meter Cable for IBM BladeCenter</br>(connector color is Gray)

Click image to enlarge

IBM CX4 1.5 or 3-meter Cable for IBM BladeCenter
(connector color is Gray)

Figure  3. IBM CX4 1.5 or 3-meter Cable for IBM BladeCenter</br>(connector color is Gray)



* IBM has withdrawn this product from marketing.

9 September 2014