BladeCenter E (8677)
| A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document. |
| SBB number | Option number | Feature code | Description | Form Factor |
Slots supported |
Hot-Plug capable |
Max quantity |
|
|---|---|---|---|---|---|---|---|---|
| Networking | ||||||||
| - | 73P9057* | - | Nortel Networks Layer 2-7 Gb Ethernet Switch Module | - | SMb1,2,3,4 | Y | 4 | |
| - | 39Y9320* | - | IBM BladeCenter Copper Pass-thru Module for IBM BladeCenter8 | - | SMb 1,2,3,4 | Y | 4 | |
| - | 32R1905* | - | McData 4Gb 10-port Fibre Channel Switch Module for eServer1 | StFF | SMb 3,4 | Y | 2 | |
| - | 32R1904* | - | QLogic 4Gb 10-port Fibre Channel Switch Module for eServer | - | SMb 3,4 | Y | 2 | |
| - | 32R1892* | - | Cisco Systems Intelligent Gb Ethrnt Sw Mod for IBM BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| - | 32R1888* | - | Cisco Systems Fiber Intelligent Gb Ethrnt Sw Mod for IBM BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| - | 32R1833* | - | McDATA 4Gb 20-port Fibre Channel Module for eServer BladeCenter1 | StFF | SMb 3,4 | Y | 2 | |
| - | 32R1813* | - | Brocade 4Gb 10-port SAN Switch Module for IBM eServer BladeCenter1,2,3,4 | StFF | SMb 3,4 | Y | 2 | |
| - | 32R1812* | - | Brocade 4Gb 20-port SAN Switch Module for IBM eServer BladeCenter | - | SMb 3,4 | Y | 2 | |
| - | 32R1783* | - | Nortel 10Gb Uplink Ethernet Switch Module for IBM BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| - | 26R0881* | - | QLogic 4Gb 20-port Fibre Chan Switch Module for eServer1,2,3 | StFF | SMb 3,4 | Y | 2 | |
| - | 26K6531* | - | Nortel L2/3 Fiber GbESM for IBM eServer BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| - | 26K6530* | - | Nortel L2/3 Copper GbESM for IBM eServer BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| - | 26K6454* | - | Topspin InfiniBand switch module for IBM eServer BladeCenter | - | SMb 3,4 | Y | 2 | |
| - | 13N2281* | - | Cisco Systems Intelligent Gb Ethernet Switch Module | - | SMb 1,2,3,4 | Y | 4 | |
| 32R1862 | 32R1859 | 1494 | IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module | StFF | SMb 1,2,3,4 | Y | 4 | |
| 32R1863 | 32R1860 | 1495 | IBM BladeCenter Layer 2/3 Copper Gb Ethernet Switch Module | StFF | SMb 1,2,3,4 | Y | 4 | |
| 32R1864 | 32R1861 | 1496 | IBM BladeCenter Layer 2/3 Fiber Gb Ethernet Switch Module | StFF | SMb 1,2,3,4 | Y | 4 | |
| 32R1901 | 32R1900* | 1499 | Cisco Systems InfiniBand switch module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 39Y9317 | 39Y9316 | 1556 | IBM BladeCenter Optical Pass-thru Module for IBM BladeCenter7 | StFF | SMb 1,2,3,4 | Y | 4 | |
| 39Y9325 | 39Y9324 | 1484 | Server Connectivity Module for IBM BladeCenter | StFF | SMb 1,2,3,4 | Y | 4 | |
| - | 90P0165* | - | Brocade Enterprise SAN Switch Module | - | SMb 3,4 | Y | 2 | |
| - | 26K6547 | - | Cisco Fiber GbESM for IBM eServer BladeCenter | - | SMb 1,2,3,4 | Y | 4 | |
| 39Y9279 | 39Y9280* | 2983 | Cisco Systems 4Gb 20-port Fibre Channel Module | - | SMb 3,4 | Y | 2 | |
| 39Y9283 | 39Y9284* | 2984 | Cisco Systems 4Gb 10-port Fibre Channel Module | - | SMb 3,4 | Y | 2 | |
| - | 43W6725* | - | Qlogic 20-port 4Gb SAN Switch Module for IBM BladeCenter | StFF | SMb 3,4 | Y | 2 | |
| - | 43W6724* | - | Qlogic 10-port 4Gb SAN Switch Module for IBM | StFF | SMb 3,4 | Y | 2 | |
| - | 43W6723* | - | QLogic 4Gb Intelligent Pass-thru Module for IBM12 | StFF | SMb 3,4 | Y | 2 | |
| 39Y9194 | 39Y9195 | 2980 | IBM BladeCenter SAS Connectivity Module11 | - | SMb 3,4 | Y | 2 | |
| 41Y8520 | 41Y8522* | 2988 | Cisco Catalyst Switch 3110X for IBM BladeCenter10 | StFF | SMb1,2,3,4 | Y | 4 | |
| 41Y8521 | 41Y8523* | 2989 | Cisco Catalyst Switch 3110G for IBM BladeCenter10 | StFF | SMb1,2,3,4 | Y | 4 | |
| 43W4398 | 43W4395* | 5450 | Cisco Catalyst Switch Module 3012 for IBM BladeCenter | StFF | SMb1,2,3,4 | Y | 4 | |
| 44W4484 | 44W4483 | 5452 | Intelligent Copper Pass-thru Module for IBM BladeCenter | - | SMb1,2,3,4 | Y | 4 | |
| 44W4405 | 44W4404 | 1590 | IBM BladeCenter 1/10Gb Uplink Ethernet Switch Module | - | SMb1,2,3,4 | Y | 4 | |
| 44X1908 | 44X1905 | 5478 | QLogic 20-port 8Gb SAN Switch Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 44X1910 | 44X1907 | 5482 | QLogic 8Gb Intelligent Pass-thru Module for IBM BladeCenter12 | - | SMb 3,4 | Y | 2 | |
| 44X1922 | 44X1920 | 5481 | Brocade 20-port 8Gb SAN Switch Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 44X1923 | 44X1921 | 5483 | Brocade 10-port 8Gb SAN Switch Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 42C1829 | 42C1828 | 5764 | Brocade Enterprise 20-port 8Gb SAN Switch Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 39Y9129 | - | 1615 | Nortel Port Aggregator L1 39Y9128 | - | - | - | - | |
| 88Y6055 | - | A1A6 | Cisco 10GBASE-SR SFP+ Transceiver | - | - | - | - | |
| 88Y6059 | - | A1A7 | Cisco 1000BASE-T SFP Transceiver | - | - | - | - | |
| 88Y6063 | - | A1A8 | Cisco 1000BASE-SX SFP Transceiver | - | - | - | - | |
| 88Y6407 | 88Y6406 | A24C | QLogic 20-port 4/8 Gb SAN Switch Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| 88Y6411 | 88Y6410 | A24D | QLogic 4/8 Gb Intelligent Pass-thru Module for IBM BladeCenter | - | SMb 3,4 | Y | 2 | |
| - | 32R1822 | - | Brocade 10-port Upgrade for IBM BladeCenter | - | - | - | - | |
| - | 73P6100 | - | IBM eServer BladeCenter Copper Pass-thru Module | - | 1,2,3,4 | Y | 4 | |
| - | 48P7062 | - | BladeCenter 2-port Fibre Channel Switch Module | - | SMb1,2,3,4 | Y | 4 | |
| - | 48P7054 | - | BladeCenter 4-port Gb Ethernet Switch Module | - | SMb 1,2,3,4 | Y | 4 | |
| - | 32R1790 | - | McDATA® 6-port Fibre Channel Switch Module for BladeCenter | - | 3,4 | Y | 2 | |
| - | 26K6477 | - | QLogic 6-Pt Enterprise Fibre Channel Switch Module | - | 3,4 | Y | 2 | |
| - | 26K5601 | - | Brocade Entry SAN Switch Module 4 | - | 3,4 | Y | 2 | |
| - | 13N0568 | - | BladeCenter 4-port Gb Ethernet Switch Module | - | SMb 1,2,3,4 | Y | 4 | |
| - | 02R9080 | - | BladeCenter Optical Pass-thru Module | - | 1,2,3,4 | Y | 4 | |
| Systems Management | ||||||||
| 25R5779 | - | 1604 | IBM BladeCenter KVM/Advanced Management Module9 | - | Red KVM | Y | 1 | |
| - | 48P7055* | - | BladeCenter Redundant KVM/Management Module | - | Red KVM | Y | 1 | |
| - | 17351GX* | - | IBM Local 2x8 Console Manager (LCM2) | - | - | - | - | |
| - | 17352GX* | - | IBM Global 2x16 Console Mngr(GCM2) | - | - | - | - | |
| Blade Server Expansion Cards | ||||||||
| - | 46M6730* | - | IBM BladeCenter PCI Express Gen 2 Expansion Blade | - | - | - | - | |
| - | 46M6772* | - | IBM BladeCenter GPU Expansion Blade with NVIDIA Tesla M2070Q | - | - | - | - | |
| - | 46M6771* | - | IBM BladeCenter GPU Expansion Blade with NVIDIA Tesla M2075 | - | - | - | - | |
| Other I/O | ||||||||
| - | 32R1878* | - | IBM 10GbE 1310nm Fiber XFP Transceiver (LR) | - | - | - | - | |
| 32R1879 | 32R1877* | 4360 | IBM 10GbE 850nm Fiber XFP Transceiver (SR) | - | - | - | - | |
| 39Y9122 | - | 4299 | IBM Short Wave SFP Module | - | - | - | - | |
| 41Y8599 | - | 4864 | Cisco Systems 4Gb Short-wave Length SFP Module for IBM BladeCenter | - | - | - | - | |
| 44W4409 | - | 4942 | 10GbE 850 nm Fiber SFP+ Transceiver (SR) for IBM BladeCenter | - | - | - | - | |
| 44X1968 | - | 5075 | IBM 8Gb SFP+ SW Optical Transceiver15 | - | - | - | - | |
| 44X1966 | - | 5084 | Brocade 8Gb SFP+ SW Optical Transceiver14 | - | - | - | - | |
| - | 25K8373* | - | IBM eServer BladeCenter PCI I/O Expansion Unit II13 | - | - | - | - | |
| - | 43W4391 | - | IBM BladeCenter PCI Express I/O Expansion Unit | - | - | - | - | |
| - | 22R4242 | - | 4Gb Short Wave SFP Module | - | 3,4 | Y | 2 | |
Notes:
- Mixing Ethernet (including Copper Pass-thru Module (CPM) and Fibre/SAN switches in I/O module bays 3 and 4 is not supported. However, mixing Optical Pass-thru modules (OPM) and Ethernet or Fibre/SAN switches in bays 3 and 4 is supported.
- A short-wave or long-wave SFP Module (SBBs 39Y9122 or 41Y8599 or option 22R4242) is required for each fibre channel port connection.
- Installs in I/O module bays 3 or 4. When installed in bay 3, port 1 is enabled on blade-installed Fibre Channel expansion cards. When installed in bay 4, port 2 is enabled on blade- installed Fibre Channel expansion cards.
- The Brocade switch modules for BladeCenter allows the interconnection of up to 239 switches.
- Maximum of four allowed in BC and BCT. If supported in BCE, then a maximum of two allowed. Can be installed in any I/O module bay. When installed in I/O module bay 1, integrated Ethernet controller 1 is enabled on all blades. When installed in bay 2, integrated Ethernet controller 2 is enabled on all blades. Installation in I/O module bays 3 or 4 (not supported in BCE) requires an Ethernet expansion card to be installed in blade servers.
- SFPs are not included and are available from Cisco (P/N GLC-SX-MM=).
- OPM provides 2Gb data rate when used with any Fibre Channel Expansion Card.
- Copper Pass-thru Modules come with one cable. Each module can support up to three cables
- One Management Module or Advanced Management Module is standard in the BladeCenter (8677). A maximum of two matched modules are supported, (i.e. two Management Modules or two Advanced Management Modules).
- A transceiver must be purchased directly from Cisco, or Cisco reseller.
- The connectivity module is exclusively supported by the advanced management module. Before you configure the connectivity module, make sure the advanced management modules in your BladeCenter unit are correctly configured. For more information about the advanced management module, see the User's Guide for your advanced management module and at http://www.ibm.com/systems/support/
- The direct connection to SAN devices is not supported. This option requires an NPIV aware external switch to operate correctly.
- The BladeCenter PCI I/O Expansion Unit provides two 64-bit/100MHz PCI-X slots. The expansion unit itself occupies one BladeCenter slot and attaches to the blade server. Both units are installed together into the BladeCenter chassis as a single unit occupying two BladeCenter slots.
- Only supported for Brocade 8Gb SAN Switches (44X1920,44X1921,42C1828)
- Only supported for QLogic 8Gb Intelligent Pass-thru Module for IBM BladeCenter(44X1907) and Qlogic 20-port 8Gb SAN Switch Module for IBM BladeCenter(44X1905)
- Form Factor abbreviations are as follows: SFF = Small Form Factor, StFF = Standard Form Factor, HSFF = High Speed Form Factor. The Standard Form Factor (StFF) card is the original form factor for expansion cards in blade servers. An StFF expansion card uses the PCI-X connector on the blade server and expansion units. When an StFF expansion card is installed using the PCI-X connector it is not possible to install a CFFh nor HSFF expansion card on the adjacent PCI-E connector (if one exists in the server) In addition, when an StFF expansion card is installed, the second hard disk drive on some blade servers cannot be installed.