System x I/O option attributes
| A four-digit feature code is used to specify a component that is configurable in the IBM configurators, the eBusiness Configurator (eConfig) and the IBM Web-based Hardware Configurator, used in US and Canada. Options that do not have feature codes cannot be integrated by IBM into a system using these IBM configurators. To purchase options separately, refer to the option part number provided in this document. |
| Option number | Description | Adapter length | PCI support1 | Low-profile capable | Hot-plug2 |
|---|---|---|---|---|---|
Storage controllers |
|||||
39M5894 |
DS4000 FC 4 Gbps PCI-X Single Port HBA |
Half |
64-bit/133MHz4 |
- |
- |
39M5895 |
DS4000 FC 4 Gbps PCI-X Single Port HBA |
Half |
64-bit/133MHz4 |
- |
- |
39R8805 |
ServeRAID-7t SATA RAID controller7 |
Half |
64-bit/66MHz |
X |
- |
71P8594 |
Single Channel Ultra320 SCSI controller8 |
Half |
64-bit/133MHz4 |
X |
- |
Fibre Storage controllers and options9 |
|||||
174290U |
FAStT900 Storage server (US line cord) |
- |
- |
- |
- |
17421RU |
FAStT700 Fibre Channel Storage server |
- |
- |
- |
- |
172260U |
FAStT600 Storage server (US line cord, English pubs) |
- |
- |
- |
- |
Networking |
|||||
26R0881 |
QLogic 4Gb 20-port Fibre Channel Switch Module for IBM |
StFF |
- |
- |
X |
32R1812 |
Brocade 4Gb 20-port SAN Switch Module for IBM |
StFF |
- |
- |
X |
32R1813 |
Brocade 4Gb 10-port SAN Switch Module for IBM |
StFF |
- |
- |
X |
32R1859 |
Nortel Networks Layer 2-7 Gb Ethernet Switch Module for IBM |
StFF |
- |
- |
X |
32R1860 |
Nortel Networks Layer L2/L3 Copper Gb Ethernet Switch Module for IBM |
StFF |
- |
- |
X |
32R1861 |
Nortel Networks Layer L2/L3 Fiber Gb Ethernet Switch Module for IBM |
StFF |
- |
- |
X |
32R1888 |
Cisco Systems Fiber Intelligent Gb Ethernet Switch Module for IBM |
StFF |
- |
- |
X |
32R1892 |
Cisco Systems Intelligent Gb Ethernet Switch Module for IBM |
StFF |
- |
- |
X |
39Y9324 |
Server Connectivity Module for IBM |
StFF |
- |
- |
- |
39Y9316 |
Optical Pass-thru Module for IBM |
StFF |
- |
- |
X |
39Y9320 |
Copper Pass-thru Module for IBM |
StFF |
- |
- |
X |
22P4501 |
Intel Pro/100S Desktop adapter11 |
Half |
32-bit/33MHz |
- |
- |
22P6501 |
Pro/1000 T Desktop Adapter by Intel12 |
Half |
32-bit/33MHz |
- |
- |
22P7801 |
NetXtreme 1000 SX Fibre ethernet adapter14 |
Half |
64-bit/133MHz6 |
X |
X |
31P6301 |
NetXtreme 1000 T ethernet adapter (copper)12, 14 |
Half |
64-bit/133MHz6 |
X |
X |
31P6401 |
NetXtreme 1000 T Dual Port ethernet adapter (copper)10 |
Half |
PCIe 1X |
- |
X |
System Management13 |
|||||
32R0835 |
IBM BladeCenter T Advanced Management Module |
- |
- |
- |
X |
03K9309 |
Advanced System Management interconnect cable kit14 |
- |
- |
- |
- |
09N7585 |
Remote Supervisor Adapter15 |
Half |
32-bit |
- |
- |
39Y9566 |
Remote Supervisor Adapter II Slimline16 |
- |
- |
- |
- |
Communications |
|||||
1519100 |
IXA Adapter17 |
Full |
64-bit |
- |
- |
22P5888 |
PCI Parallel port adapter (low profile) |
Half |
32-bit |
- |
- |
Related I/O cables |
|||||
32P8164 |
External SCSI interface kit18 |
- |
- |
- |
- |
10K3661 |
USB to Serial Adapter19, 20 |
- |
- |
- |
- |
- Adapters rated at a lower frequency than the slots in which
they are installed will reduce the bus to the frequency of the
slowest adapter. 133MHz PCI-X adapters are backward compatible
with 33/66MHz, 64-bit PCI-based servers. - Hot-plug feature only supported in systems with Active PCI
slots. For network operating system support, point your browser
to www.pc.ibm.com/us/compat. - ServeRAID-6i+ Controller is a PCI-X adapter supporting both
Ultra320 and Ultra160 HDDs in a dedicated or mixed environment,
allowing each HDD to perform at rated capacity. The adapter
installs into limited PCI slots and converts both channels of
the integrated SCSI controller to RAID in conjunction with the
LSI 1030 chipset. Both standard and the optional SCSI HDD backplanes
as well as internal tape drives and external SCSI devices cabled
directly to the onboard controller connectors. Supports up to
1,064MB/s data transfers across the PCI bus with 128MB ECC SDRAMM
write-back cache with battery backup. Supports RAID levels 0, 1,
10, 5, 50 and 1E. The option includes brackets for installation
in both low-profile and standard PCI slots. Internal and external
tape drives are supported by ServeRAID-6i+ only when a second
channel on the integrated controller is available and the RAID
configuration designates the second channel as a conventional
SCSI bus. See system sections for supported tape drives. - This adapter is designed using PCI-X technology.
- ServeRAID-6M adapters are PCI-X adapters powered
by a 600MHz Intel xScale processor, providing 256MB or 128MB of
ECC SDRAM battery-backed cache. The dual-channel Ultra320 controller
includes two internal 68-pin connectors and two external 0.8mm VHDCI
connectors, supporting up to 14 HDDs on each channel at data transfer
rates of up to 1,064MB/s. Supports RAID levels 0, 1, 10, 1EO, 5,
50 and 5EE with both Ultra160 and Ultra320 HDDs. - ServeRAID-7k is available for select systems, installs into
a dedicated slot and does not consume a PCI slot. It works in
conjunction with the integrated SCSI controller providing the
following RAID levels: 0, 00, 1, 10, 1E, 1E0, 5 and 50 with
256MB of ECC DDR1 battery-backed cache. - ServeRAID-7t is a low-profile capable, four-port SATA controller
supporting RAID levels 0, 1, 5 and 10. All ports are internal.
ServeRAID-7t is a universal PCI 2.2 compliant adapter powered by
Intel's 400MHz 80302 I/O processor and has 64MB of cache. - Single Channel Ultra320 SCSI Controller (P/N 71P8594) provides
a single channel with one 68-pin internal connector, a four-drop
multimode terminated LVD SCSI cable and one external 0.8mm VHDCI
connector. Only one of the two connectors may be utilized.
Hardware is included in the option to support either low-profile
(2U) or full-size (3U) installations. - See Fibre Channel Solutions Overview section for additional
configuration information. - The option includes brackets for installation in both low-profile
and full-size PCI slots. - For use of the Alert on LAN 2 features in the Desktop adapter,
the system must be enabled with IBM-compatible Alert on LAN 2
hardware and software components. Use of the Wake on LAN function
requires a PCI 2.2 compatible system that supports Wake on LAN
and provides auxiliary 3.3v power through the PCI bus. - Use of the Wake on LAN function requires a PCI 2.2 compatible
system that supports Wake on LAN and provides auxiliary power through
the PCI bus. - Up to 24 Integrated System Management Processors or Remote
Supervisors Adapters may be interconnected with an aggregate
connection length of no more than 91.4m (300ft). This
interconnect network of 24 devices may also include a maximum
of 12 Advanced System Management Processors or advanced System
Management PCI Adapters. A customer-supplied Cat5 cable is
required for each interconnection. - When a standard Remote Supervisor Adapter or ASM PCI Adapter
is installed in a dedicated PCI slot with an external connector,
support for connection to other servers in an ASM interconnect
network requires an optional Advanced System Management Interconnect
Cable Kit (P/N 03K9309). Where applicable, direct connection to the
RXE drawer management controller in an RXE-100 Remote Expansion
Enclosure is supported through a standard Interconnect Management
Cable Kit with 3.5m cable (8m optional cable is available). Support
is provided through a single LAN or modem connection. - Remote Supervisor Adapter (P/N 09N7585) includes an adapter
card, 20-pin ribbon cable, AC power adapter, power cable, power
cable for UPS attachment, single pigtail cable, two RS-485 terminators
and 1ft Cat5 cable. - Remote Supervisor Adapter II Slimline is similar to RSA II and
is available for select systems. It is not supported on an ASM
interconnect network. The RSA II Slimline installs into a
dedicated slot on the system board and does not consume a PCI slot.
An external AC adapter is not required as this card uses standby
power from the system's power. - Some System x servers support the IXA Adapter (P/N 1519100) for
connection to iSeries models. Refer to system sections for PCI slot
restrictions. - Required to enable external 0.8mm VHDCI connectors on some systems.
- When supported, this option can be used for certain external
device connections when only USB ports rather than serial or
parallel ports are present on a system chassis. - Available only in the US.