This PDU provides an economical, basic power distribution capability for rack-based systems, helping to enable you to satisfy the power requirements of your devices. It has one low-voltage power input and supports up to six devices with a combined power requirement of up to 1200W at 100v through 1524W at 127V. This 1U PDU is half-rack width, so you can mount two in a single 1U space for a total of 12 outlets. This PDU is primarily used in North America, Japan, Taiwan, the Philippines and various other nations that have power systems that work at 100V-127V.
 |
|
| |
Low voltage (100V-127V) |
| |
6 NEMA 5-15R power outlets |
| |
Brackets for vertical (sidewall) and horizontal (EIA space) rack mounting |
| |
Two-pole 15-amp circuit breaker with time-delay protection |
| |
Fixed 9ft (2.8m) attached line cord with NEMA L5-15P |
| |
Cable retention aids |
|
This PDU provides an economical, basic power distribution capability for rack-based systems, helping to enable you to satisfy the power requirements of each device without overtaxing your power source. It has one universal-voltage power input and supports up to seven devices with a combined power requirement of 1500W at 100Vac to 3600W at 240Vac (based on AC input volts).
 |
|
| |
7 IEC 320-C13 (10A) receptacles |
| |
Can connect directly to the wall or you can cascade multiple units to one of our front-end PDUs |
| |
Universal voltage (100-240Vac, 50-60Hz) |
| |
Mount in rack side walls, or on the EIA space. PDU is half-rack width, so you can mount two in a single 1U space |
| |
Two-pole 15-amp circuit breaker with time-delay protection |
| |
Single LED power on indicator |
| |
Cable management brackets included with PDU to help neatly and securely run cabling |
| |
39Y8951 DPI Universal Rack PDU ships with both an IEC-320-C19 to NEMA L5-20P, to connect to 110v & IEC-320-C19 to NEMA L6-20P, to connect to 208v |
|
 |
|
39Y8952 DPI Universal Rack PDU w/ CEE7-VII Europe LC 1
39Y8953 DPI Universal Rack PDU w/ Denmark LC 1
39Y8954 DPI Universal Rack PDU w/ Israel LC 1
39Y8955 DPI Universal Rack PDU w/Italy LC 1
39Y8956 DPI Universal Rack PDU w/South Africa LC 1
39Y8957 DPI Universal Rack PDU w/UK LC 1
39Y8958 DPI Universal Rack PDU with AS/NZ 3112 Australia/NZ LC 1
39Y8959 DPI Universal Rack PDU w/China LC 1
39Y8962 DPI Universal Rack PDU Argentina 1
39Y8960 DPI Universal Rack PDU Brazil 1
39Y8952 DPI Universal Rack PDU Europe 1
39Y8961 DPI Universal Rack PDU India 1
1 Available In Select Geographies
|
 |
|
DPI Single-phase Front-end PDUs provide a front-end wiring box to allow connection of multiple DPI Universal Rack models to higher-current single-phase circuits. These modular, front-end PDUs provide three single-phase output circuits from one single-phase (100V-240V at 30amp or 200V-240V at 60amp) input circuit.
 |
|
| |
Three single-phase output circuits with three IEC 320-C19 receptacles |
| |
Allows for cascading of up to 3 DPI Universal PDUs or direct attachment to IBM BladeCenter |
| |
Single Phase 30A, 32A 1, 60A, & 63A 1 offerings |
| |
Adapts to high-current circuits (three-wire, single-phase) |
| |
100V-240V at 30/32A, supports up to 3000W at 100V or up to 7200W at 240V |
| |
200V-240V at 60/63A, supports up to 9000W at 200V or up to 10,800W at 240V |
| |
Non-replaceable fuse for protection |
| |
Brackets for vertical (sidewall) rack mounting only |
| |
Power on LED indicator on each load segment |
| |
Mount in rack side walls, or on the EIA space. PDU is half-rack width, so you can mount two in a single 1U space |
|
 |
|
39Y8934 DPI 32amp/250V Front End PDU w/ IEC 309 P+N+G connector 1
39Y8935 DPI 63amp/250V Front End PDU w/ IEC 309 P + N connector 1
39Y8936 DPI Single-phase 30A/250V Front-end PDU (S Korea) 1
39Y8937 DPI Single-phase 32A/230V Front-end PDU (Aus/NZ) 1
1 Available In Select Geographies
|
 |
|
The IBM DPI Enterprise PDU makes it quick and simple to set up and protect sensitive electronic equipment. It helps customers take control of their rack environment by simplifying installation, consolidating line cords and reducing the electrical infrastructure required to feed the rack. This PDU option can be used separately or in combination with other PDUs to provide from a few outlets up to a full rack, scaling as required or as business needs change to support even greater power densities. It is designed so that the input cable, output receptacles and circuit breakers are on one face to improve usability and cable management.
 |
|
| |
Power cord connection, breakers and outlets all on the same side of PDU for easy access |
| |
Includes hardware to mount in either EIA space of sidepocket of rack |
| |
Push button breaker protection for each outlet |
| |
Can be used as either a Front End PDU or directly connected to servers |
| |
Single Phase 30A, 32A 1, 60A, & 63A 1 offerings (Line Cord Dependant) |
| |
Three Phase 32A 1 (Line Cord Dependant) & 60A offerings |
| |
C13 Model (39Y8941) has 12 IEC-320-C13 (10A) receptacles |
| |
C19 Models (39Y8948 & 39Y8923) have 6 IEC-320-C19 (16A) receptacles |
| |
Optional detachable Line Cords on 39Y8948 & 39Y8923 for future flexibility |
| |
39Y8923 IBM DPI C19 PDU+ includes IEC60309 3P+G, 60A line cord |
|
 |
|
40K9611 IBM DPI 32a Cord (IEC 309 3P+N+G) 1
40K9612 IBM DPI 32a Cord (IEC 309 P+N+G) 1
40K9613 IBM DPI 63a Cord (IEC 309 P+N+G) 1
40K9617 DPI PDU+ Australian/NZ Cord 1
40K9618 DPI PDU+ Korean Line Cord 1
1 Available In Select Geographies
|
 |
|
IBM Ultra Density Enterprise PDU models are engineered to stringent specifications in order to efficiently and cost effectively deliver power to the most power-dense IBM System x and BladeCenter environments. Designed with nine IEC-320-C19 (16A) receptacles on the front, three IEC-320-C13 (10A) on the rear panel, and individual breakers per load group, these units are well equipped to meet the requirements of your most power-demanding and highest availability systems.
 |
|
| |
Input cable connection, C19 outlets, and breakers on one face to improve usability and cable management |
| |
Hardware to mount in either EIA space or sidepocket of rack |
| |
7176-2NX and 7176-3NU have nine IEC-320-C19 (16A) receptacles on front panel and three IEC-320-C13 (10A) receptacles on rear panel |
| |
Easily accessible individual breakers per load group for high-availability environments |
| |
Single Phase 30A, 32A 1, 60A, & 63A 1 offerings (DPI® line cord dependant) |
| |
Three Phase 32A 1(DPI line cord dependant) and 60A fixed line cord offerings |
| |
Optional detachable DPI line cord on 7176-2NX IBM Ultra Density Enterprise C19/C13 PDU Module for future flexibility |
| |
7176-3NU IBM Ultra Density Enterprise C19/C13 PDU+ 60A/208V/3 phase includes fixed IEC60309 3P+G, 60A line cord |
| |
3 Year Limited Warranty |
|
 |
|
40K9611 IBM DPI 32a Cord (IEC 309 3P+N+G) 1
40K9612 IBM DPI 32a Cord (IEC 309 P+N+G) 1
40K9613 IBM DPI 63a Cord (IEC 309 P+N+G) 1
40K9617 DPI PDU+ Australian/NZ Cord 1
40K9618 DPI PDU+ Korean Line Cord 1
1 Available In Select Geographies
|
 |
|
| |
|