IBM System Storage N7000 Modular Disk Storage System


Tab navigation

Highlights

In an increasingly demanding and competitive business landscape, effective data management is essential to the success of your business. Employees, partners and customers need access to up-to-date information to work productively, make timely decisions and meet business goals. IT is under pressure to deliver more storage capacity at higher levels of service. Yet critical resources, including staffing, budget, power, cooling and floor space, are often constrained. Storage efficiency becomes the key to keeping pace with this growing environment.

These demands call for enterprise-class storage systems with the flexibility to support changing IT requirements, accommodate continuous data growth, satisfy application-level service requirements of network attached storage (NAS) environments and support SAN infrastructures – all at a low overall cost.

Feature Benefits
Data compression
Deduplication
Data ONTAP
Disk sanitisation
Flash Pool (requires Data ONTAP 8.1.1 or later version)§
FlexCache
FlexClone
FlexShare
FlexVol
Gateway
MetroCluster
MultiStore
NearStore (nearline)
OnCommand
Protection Manager
Provisioning Manager
RAID-DP
SecureAdmin
Single Mailbox Recovery for Exchange (SMBR)
SnapDrive
SnapLock (Data ONTAP v8.1 and later version)
SnapManager
SnapMirror
SnapMover
SnapRestore
Snapshot
SnapValidator
SnapVault
Storage Encryption
SyncMirror
System Manager
Software bundles
Specifications
  N7950T
Machine type model 2867-E22
Gateway machine type model 2867-E22 (with FC 9551)
Controller configuration Dual (active/active)
Processors speed and type 2.93 GHz Intel® 6-core
Number of processors 24
Random access memory (RAM) 192 gigabytes (GB)†
Non-volatile memory 8 GB
Integrated I/O ports
FC ports/speed 8 (8 Gbps)
SAS ports/speed (requires FC 1080) 0 – 24 (6 Gbps)
Ethernet ports/Speed 8 (10 Gbps), 4 (1 Gbps)
Storage scalability
Maximum number of FC loops 14
Maximum number of SAS stacks 10
Maximum raw capacity* 4,320 TB
Maximum number of disk drives 1,440
Maximum volume size 100 TB
Maximum number of logical unit numbers (LUNs) 4,096
Maximum number of SAN Hosts Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
Maximum number of storage enclosures 84
Disk expansion units supported EXN4000 - FC disk storage expansion unit: 4 Gbps FC: 300 GB, 450 GB, 600 GB (15k revolutions per minute (rpm))
EXN3500 - SAS disk storage (small-form factor (SFF)) expansion unit: SAS: 450 GB, 600 GB, 900 GB (10k rpm)
EXN3200 - SATA disk storage (hard disk drive (HDD)) expansion unit: 3 TB (7.2k rpm)
EXN3000 - SAS disk storage expansion unit: SAS: 300 GB, 450 GB, 600 GB (15k rpm); SATA: 1 TB, 2 TB, 3 TB (7.2k rpm), 100 GB solid state drive (SSD)
EXN1000 - SATA disk storage expansion unit: SATA: 1 TB, 2 TB (7.2k rpm)
I/O scalability
PCIe expansion slots 24
PCI-Extended (PCI-X) expansion slots 0
Maximum number of FC ports 128
Maximum number of Ethernet ports 100
Maximum number of SAS ports 72
Maximum number of adapters supported per system (below - not to exceed maximum number of optional adapters)
1012 - Dual-port gigabit Ethernet (GbE) network interface card (NIC) (fibre) 24
1014 - Dual-port 4 gigabits per second (Gbps) FC host bus adapter (HBA) disk 24
1015 - Dual-port 4 Gbps FC HBA tape 16
1028 - Quad-port GbE (copper) 12
1029 - Quad-port 4 Gbps FC HBA disk 24
1030 - Quad-port 4 Gbps FC target 12
1036 - Peripheral component interconnect express (PCIe) 2 port 8 gigabit (Gb) FC target HBA 24
1061 - Quad-port 3 Gbps SAS adapter for disk attachment** 12
1063 - Dual-port FCoE adapter (optical) 24
1064 - Dual-port FCoE adapter (cooper) 24
1066 - MetroCluster VI FC HBA 8 Gb 2
1067 - SnapMirror over FC HBA 8 Gb 4
1071 - Flash Cache II 512 Gb 32
1072 - Flash Cache II 1 terabit (Tb) 16
1078 - Dual-port 10 GbE NIC, small form-factor pluggable (SFP+) 16
1079 - Quad-port 8 Gb FC HBA 6
1080 - Quad-port 6 Gb SAS HBA 6
2013 - SFP+ 10 GbE - embedded NIC 8
2014 - SFP+ optical module for 1078 32
Warranty Three years for hardware and licensed software, customer replaceable unit (CRU) and on-site service, next business day 09:00 to 17:00, service upgrades available

Environmental Specifications and Regulations

Environmental specifications
  N7950T
Machine type model 2867-E22
Gateway machine type model 2867-E22 (with FC 9551)
AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 – 240 V only) 100 – 120 V ac, 6.9 A (typical), 9.6 A (maximum) @ 100 V ac
200 – 240 V ac, 3.5 A (typical), 4.7 A (maximum) @ 200 V ac
Thermal rating 6,486 British thermal units (BTU)/hr (max), 4,540 BTU/hr (typical)
Weight (maximum) 118 kg (260.2 lb)
Height 52.42 cm (20.64 in.), fits into 12U space
Width 19 in. IEC rack-compliant (44.6 cm, 17.6 in.)
Depth 61 cm (24 in.), 73.66 cm (29 in.) with cable management bracket
Operating temperature, altitude and relative humidity 10°C – 40°C (50°F – 104°F); at ≤ 3,050 m (≤ 10,000 ft.) elevation; 20% – 80% relative humidity, non-condensing (28°C wet bulb temperature)
Non-operating temperature and relative humidity -40°C – 70°C (-40°F – 158°F); 10% – 95% relative humidity, non-condensing, in original container
Operating acoustic noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Minimum cabinet clearances 15.2 cm (6 in.) in front, 30.5 cm (12 in.) in rear
Minimum service clearances 63.5 cm (25 in.) from front of cabinet; 102 cm (40 in.) from rear of cabinet
Maximum altitude 2,133 m (7,000 ft.)
Regulations
Filer safety EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition), CB (all national deviations), EN 60825-1:2007, IRAM, GOST-R
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI
Immunity EN 55024:1998 +A1:2001 +A2:2003
Storage expansion unit disk drive support
EXN4000 – 4 Gbps FC disk storage expansion unit (MTM 2863-004) FC: 300 GB, 450 GB, 600 GB (15k rpm)
EXN3500 – SAS SFF disk storage expansion unit (MTM 2857-006) SAS SFF: 450 GB, 600 GB, 900 GB (10k rpm)
EXN3200 – SATA disk storage expansion unit HDD (MTM 2857-306) SATA: 3 TB (7.2k rpm)
EXN3000 – SAS disk storage expansion unit (MTM 2857-003) SAS: 300 GB, 450 GB, 600 GB, 600 GB SED (15k rpm)
SATA: 1 TB, 2 TB, 3 TB (7.2k rpm); 100 GB SSD
EXN1000 SATA disk storage expansion unit (MTM 2861-001) SATA: 1 TB, 2 TB (7.2k rpm)
Storage expansion unit specifications
Disk storage expansion units supported EXN4000: 4 Gbps FC disk storage expansion unit (MTM 2863-004) with 14 low-profile slots for FC disk drives
EXN3500: SAS SFF disk storage expansion unit (MTM 2857-006) with 24 SFF slots for SAS SFF disk drives
EXN3200: SATA disk storage expansion unit (MTM 2857-306) with 24 dual HDD slots for 3.5 in. HDD product platforms
EXN3000: SAS disk storage expansion unit (MTM 2857-003) with 24 slots for SAS disk drives
EXN1000: SATA disk storage expansion unit (MTM 2861-001) with 14 low-profile slots for SATA disk drives
Legacy support for expansion units
Disk drive storage shelf interface PCIe-based FC-Arbitrated Loop (FC-AL) or SAS
Environmental specifications
Power supply/cooling fans EXN3000: Dual (SATA) or Quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V)
EXN1000, EXN3500, EXN4000: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V)
EXN3200: Quad redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V)
AC power/maximum current 100 – 120 V ac/4.4 A; 200 – 240 V ac/2.3 A 100 – 120 V ac/7 A; 200 – 240 V ac/3.5 A; 50/60 Hz
Operating temperature maximum range 10°C – 40°C (50°F – 104°F)
Recommended operating temperature range 20°C – 25°C (68°F – 77°F)
Operating relative humidity range 10% – 95% relative humidity, non-condensing 10% – 95%
Recommended operating relative humidity range 40% – 55% non-condensing
Non-operating temperature range -40°C – 65°C (-40°F – 149°F)
Non-operating relative humidity range 10% – 95% relative humidity, non-condensing
Thermal rating 1,215 Btu/hr (fully loaded disk storage expansion unit)
Operating acoustic noise 56.4 dBA @ 1 m at 23°C, 5.64 bels @ 23°C
Dimensions (height/width/depth) EXN4000 and EXN1000
3U EIA (13.3 cm, 5.25 in.) H/19 in. IEC rack-compliant (44.7 cm, 17.6 in.) W/50.8 cm, 20 in.) D
EXN3500
2U EIA (8.5 cm, 3.4 in.) H/19 in. IEC rack-compliant (44.7 cm, 17.6 in.) W/50.8 cm (20 in.) D
EXN3200
4U EIA (17.47 cm, 6.88 in.) H/19 in. IEC rack-compliant (44.72 cm, 17.61 in.) W/69.21 cm (27.25 in.) D
EXN3000
4U EIA (17.49 cm, 6.9 in.) H/19 in. IEC rack-compliant (44.87 cm, 17.7 in.) W/65.35 cm (25.7 in.) D
Weight EXN4000 - 35.8 kg (78.8 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty (without PCMs and power supply units (PSUs))
EXN3500 - 22.2 kg (49 lb) fully loaded with disk drives, 15.7 kg (34.6 lb) empty
EXN3200: 68.04 kg (150 lb) fully loaded with disk drives, 17.69 kg (39 lb) empty
EXN3000 - 49.9 kg (110 lb) fully loaded with disk drives, 24.4 kg (53.7 lb) empty
EXN1000 - 35 kg (77 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty
Regulations
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

Operating system
Data ONTAP 7.2.5 or later
Operating system support Microsoft Windows, Microsoft Windows Server, Sun Solaris, IBM AIX, HP-UX, Macintosh OS, Linux, VMware ESX
Standard software features Integrated automatic RAID manager, including RAID-DP, Snapshot, Fast Boot, Telnet, email alerts, NIS, domain name system (DNS), simple network management protocol (SNMP), SecureAdmin, Flash Pool, FlexVol, FlexShare, SSH, Maintenance Centre, Network Data Management Protocol (NDMP)
Network protocol support Network file system (NFS) V2/V3/V4 over user datagram protocol (UDP) or transmission protocol (TCP), PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft common internet file system (CIFS), VLD, file transfer protocol (FTP), hypertext transfer protocol (HTTP) 1.0, HTTP 1.1 Virtual Hosts
SAN protocol support FC Protocol (FCP), FCoE for SCSI (2 Gb and 4 Gb); fabric-attached and direct-attached; iSCSI
Optional licensed functions NFS, CIFS, HTTP, FCP, iSCSI Protocol, FCoE, FlexCache, FlexClone , FlexScale, MultiStore, Clustered Failover (CFO), SnapMirror, SnapRestore, SMBR for Exchange, SnapManager for Exchange, SnapManager for SQL Server, SnapManager for Oracle, SnapManager for SAP, SnapManager for Microsoft Office SharePoint (SMSP), SnapManager for Virtual Infrastructure, SnapManager for Microsoft Hyper-V, SnapVault, SnapMover, SnapLock Compliance, SnapLock Enterprise, SyncMirror, MetroCluster, NearStore, SnapValidator, SnapDrive for Windows, SnapDrive for UNIX, SnapDrive for AIX, SnapDrive for HP-UX, SnapDrive for Linux, AIX multipathing, Disk Sanitisation, Deduplication, Protection Manager, Provisioning Manager
Hardware features Full-duplex 10/100/1000 Base-T Ethernet onboard console, diagnostic light emitting diodes (LED)/liquid crystal display (LCD), Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19 in. rack-mount enclosure, optional 220 V 42U 19 in. system cabinet
Maximum RAID group sizes RAID 6 (RAID-DP) FC - 28 (26 data disks plus 2 parity disks), SATA - 16 (14 data disks plus 2 parity disks)
RAID 4 FC - 14 (13 data disks plus 1 parity disk), SATA - 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)

Contact IBM