- Overview- selected tab,
- Features and benefits
- Specifications
Highlights
- Meet diverse and changing needs. Consolidate diverse data sets onto a unified storage platform that provides simultaneous block and file services
- Perform when your applications need it most. Outstanding performance with high bandwidth, 64-bit architecture and the latest input/output (I/O) technologies
- Maximise your resources. Highly efficient storage utilisation makes it possible for you to dramatically reduce power, cooling and space demands
- Respond to growth. Preserve investments in staff expertise and capital equipment with data-in-place upgrades to more powerful N series systems
- Improve your business efficiency. Take advantage of the N6000 series Gateway capabilities to reduce data management complexity in heterogeneous storage environments.

Today’s business environment demands innovation and increasingly flawless execution. You have to manage and protect valuable data to enable business growth and success. Your IT operations have to evolve with the business while meeting budget, staffing and infrastructure limits. Virtualised computing requires networked storage systems supporting diverse data sets to unlock the full potential of virtualised servers.
With IBM N6000 series systems you can simultaneously meet your diverse needs – Storage Area Network (SAN) and Network Attached Storage (NAS), primary and secondary storage. And you get outstanding value: our flexible systems offer excellent performance and impressive scalability at a low total cost of ownership (TCO).
Common features
- Simultaneous multiprotocol support for Fibre Channel Protocol (FCP), SCSI over IP (iSCSI), Common Internet File System (CIFS), Network File System (NFS), HyperText Transfer Protocol (HTTP) and File Transfer Protocol (FTP)
- File-level and block-level service in a single system
- Upgrade up to 840 TB of physical capacity while avoiding service disruption
- Support for Fibre Channel (FC) and Serial Advanced Technology Attachment (SATA) disk drives
- Data ONTAP software
- 16 TB maximum volume size
- Broad range of built-in features
- Multiple supported backup methods including disk-based and host-based backup and tape backup to direct, SAN and Gigabit Ethernet (GbE) attached tape devices
Hardware summary
- Up to 840 TB raw storage capacity
- 4 GB to 32 GB cache memory
- 512 MB to 4 GB nonvolatile memory
- 10 GbE adapter card (optional)
- Quad-port 4 Gigabits per second (Gbps) adapters (optional)
- Up to 8 Performance Acceleration Modules
- Diagnostic Light Emitting Diode (LED)/Liquid Crystal Display (LCD)
- Dual redundant hot-plug integrated cooling fans and auto-ranging power supplies
- 19 inch, rack-mountable
| Feature | Benefits |
|---|---|
| Advanced Single Instance Storage (A-SIS) |
|
| Data ONTAP |
|
| Disk Sanitisation |
|
| FlexCache |
|
| FlexClone |
|
| FlexShare |
|
| FlexVol |
|
| MetroCluster |
|
| MultiStore |
|
| NearStore (near-line) |
|
| Operations Manager |
|
| Performance Acceleration Module |
|
| Protection Manager |
|
| Provisioning Manager |
|
| RAID-DP |
|
| SecureAdmin |
|
| Single Mailbox Recovery for Exchange (SMBR) |
|
| SnapDrive |
|
| SnapLock |
|
| SnapManager |
|
| SnapMirror |
|
| SnapMover |
|
| SnapRestore |
|
| Snapshot |
|
| SnapValidator |
|
| SnapVault |
|
| SyncMirror |
|
| System Manager |
|
| N6040 | N6040 | N6060 | N6060 | |
|---|---|---|---|---|
| Machine Type Model | 2858-A10 | 2858-A20 | 2858-A12 | 2858-A22 |
| Gateway Machine Type Model | 2858-A10 (w/FC 9551) |
2858-A20 (w/FC 9551) |
2858-A12 (w/FC 9551) |
2858-A22 (w/FC 9551) |
| Controller Configuration | Single | Dual (active/active) | Single | Dual (active/active) |
| Processors Speed and Type | 2.4 GHz AMD Dual-core 64-bit Opteron | |||
| Number of Processors | One | Two | Two | Four |
| Random Access Memory (RAM) | 4 GB | 8 GB | 8 GB | 16 GB |
| Nonvolatile Memory | 512 MB | 1 GB | 2 GB | 4 GB |
| Integrated I/O Ports | ||||
| FC Ports (Speed) | Four (4-Gbps) | Eight (4-Gbps) | Four (4-Gbps) | Eight (4-Gbps) |
| Ethernet Ports (Speed) | Two (1-Gbps) | Four (1-Gbps) | Two (1-Gbps) | Four (1-Gbps) |
| Storage Scalability | ||||
| Maximum Number of FC Loops | 10 | 10 | 10 | 10 |
| Maximum Raw Capacity | 420 TB | 420 TB | 672 TB | 672 TB |
| Maximum Number of Disk Drives | 420 | 420 | 672 | 672 |
| Maximum Volume Size | 16 TB | 16 TB | 16 TB | 16 TB |
| Maximum Number of Volumes/LUNs | 2048 | 2048 | 2048 | 2048 |
| Maximum Number of Storage Enclosures | 30 | 30 | 48 | 48 |
| Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | |||
| I/O Scalability | ||||
| PCI-e Expansion Slots | Four | Eight | Four | Eight |
| Maximum number of FC Ports | 20 | 40 | 20 | 40 |
| Maximum number of Ethernet Ports | 18 | 36 | 18 | 36 |
| Maximum Number of Optional Adapters | Four | Eight | Four | Eight |
| Storage Expansion Unit Disk Drive Support | ||||
| EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps FC: 300 GB, 15,000 revolutions per minute (rpm); 450 GB, 15,000 rpm 2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm |
|||
| EXN3000 – Serial Attached SCSI (SAS) Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB |
|||
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 500 GB, 7,200 rpm; 1 TB | |||
| Maximum Number of Adapters Supported Per System (below - not to exceed Maximum Number of Optional Adapters) | ||||
| 1012 - Dual-Port GbE NIC (fibre) | Four | Eight | Four | Eight |
| 1013 - Dual-Port GbE NIC (copper) | Four | Eight | Four | Eight |
| 1014 - Dual-Port 4-Gbps FC Host Bus Adapter (HBA) Disk | Four | Eight | Four | Eight |
| 1015 - Dual-Port 4-Gbps FC HBA Tape | Four | Eight | Four | Eight |
| 1017 - Dual-Port 4-Gbps FC HBA Target | Four | Eight | Four | Eight |
| 1021 - Dual-Port GbE iSCSI Target (fibre) | Four | Eight | Four | Eight |
| 1023 - Quad-Port GbE NIC (copper) | Four | Eight | Four | Eight |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape | Four | Eight | Four | Eight |
| 1026 - Dual-Port GbE NIC (copper) | Four | Eight | Four | Eight |
| 1029 - Quad-Port 4-Gbps FC HBA - DISK | Four | Eight | Four | Eight |
| 1030 - Quad port 4 Gbps FC Target | Four | Eight | Four | Eight |
| 1031 - Dual-Port 10-GbE TCP/IP Offload Engine (TOE) NIC | Four | Eight | Four | Eight |
| 1032 - Dual-Port MetroCluster VI HBA | Three | Six | Three | Six |
| 1033 - SnapMirror Over FC HBA PCI-e | Four | Eight | Four | Eight |
| 1035 - Quad-Port 4-Gbps FC HBA Tape/Disk | Four | Eight | Four | Eight |
| 1036 - PCIe 2 port 8 GB FC Target HBA | Four | Eight | Four | Eight |
| 1056 - Performance Acceleration Module (16 GB) | Four | Eight | Four | Eight |
| 1057 - Performance Acceleration Module (512 GB) | - | - | - | - |
| 1058 - Performance Acceleration Module (256 GB)* | Two | Four | Two | Four |
| 1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** | Four | Eight | Four | Eight |
| 1063 - Dual-port Fibre Channel over Ethernet (FCoE) adapter (optical) | Four | Eight | Four | Eight |
| 1064 - Dual-port FCoE adapter (cooper) | Four | Eight | Four | Eight |
| 1065 – Dual-port 10 Gbps Ethernet NIC card | Four | Eight | Four | Eight |
* Corequisite: Performance Acceleration Module II software feature per filer/gateway. Requires ONTAP 7.3.2
** For use with the EXN3000 and QSFP-QSFP cabling
| N6070 | N6070 | |
|---|---|---|
| Machine Type Model | 2858-A11 | 2858-A21 |
| Gateway Machine Type Model | 2858-A11 (w/FC 9551) |
2858-A21 (w/FC 9551) |
| Controller Configuration | Single | Dual (active/active) |
| Processors Speed and Type | 2.4 GHz AMD Dual-core 64-bit Opteron | |
| Number of Processors | Two | Four |
| RAM | 16 GB | 32 GB |
| Nonvolatile Memory | 2 GB | 4 GB |
| Integrated I/O Ports | ||
| FC Ports (Speed) | Four (4-Gbps) | Eight (4-Gbps) |
| Ethernet Ports (Speed) | Two (1-Gbps) | Four (1-Gbps) |
| Storage Scalability | ||
| Maximum Number of FC Loops | 10 | 10 |
| Maximum Raw Capacity | 840 TB | 840 TB |
| Maximum Number of Disk Drives | 840 | 840 |
| Maximum Volume Size | 16 TB | 16 TB |
| Maximum Number of Volumes/LUNs | 2048 | 2048 |
| Maximum Number of Storage Enclosures | 60 | 60 |
| Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | |
| I/O Scalability | ||
| PCI-e Expansion Slots | Four | Eight |
| Maximum number of FC Ports | 20 | 40 |
| Maximum number of Ethernet Ports | 18 | 36 |
| Maximum Number of Optional Adapters | Four | 8 |
| Storage Expansion Unit Disk Drive Support | ||
| EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm 2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm |
|
| EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB |
|
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 500 GB, 7,200 rpm; 1 TB | |
| Maximum Number of Adapters Supported Per System (below - not to exceed Maximum Number of Optional Adapters) | ||
| 1012 - Dual-Port GbE NIC (fibre) | Four | Eight |
| 1013 - Dual-Port GbE NIC (copper) | Four | Eight |
| 1014 - Dual-Port 4-Gbps FC HBA Disk | Four | Eight |
| 1015 - Dual-Port 4-Gbps FC HBA Tape | Four | Eight |
| 1017 - Dual-Port 4-Gbps FC HBA Target | Four | Eight |
| 1021 - Dual-Port GbE iSCSI Target (fibre) | Four | Eight |
| 1023 - Quad-Port GbE NIC (copper) | Four | Eight |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape | Four | Eight |
| 1026 - Dual-Port GbE NIC (copper) | Four | Eight |
| 1029 - Quad-Port 4-Gbps FC HBA - DISK | Four | Eight |
| 1030 - Quad port 4 Gbps FC Target | Four | Eight |
| 1031 - Dual-Port 10-GbE TOE NIC | Four | Eight |
| 1032 - Dual-Port MetroCluster VI HBA | Two | Four |
| 1033 - SnapMirror Over FC HBA PCI-e | Four | Eight |
| 1035 - Quad-Port 4-Gbps FC HBA Tape/Disk | Four | Eight |
| 1036 - PCIe 2 port 8 GB FC Target HBA | Four | Eight |
| 1056 - Performance Acceleration Module (16 GB) | Four | Eight |
| 1057 - Performance Acceleration Module (512 GB)* | Two | Four |
| 1058 - Performance Acceleration Module (256 GB) | - | - |
| 1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** | Four | Eight |
| 1063 - Dual-port FCoE adapter (optical) | Four | Eight |
| 1064 - Dual-port FCoE adapter (cooper) | Four | Eight |
| 1065 – Dual-port 10 Gbps Ethernet NIC card | Four | Eight |
* Corequisite: Performance Acceleration Module II software feature per filer/gateway. Requires ONTAP 7.3.2
** For use with the EXN3000 and QSFP-QSFP cabling
Environmental Specifications and Regulations for Appliance and Gateway Models
| Environmental Specifications | N6040 | N6040 | N6060 | N6060 |
|---|---|---|---|---|
| Machine Type Model | 2858-A10 | 2858-A20 | 2858-A12 | 2858-A22 |
| Gateway Machine Type Model | 2858-A10 (w/FC 9551) |
2858-A20 (w/FC 9551) |
2858-A12 (w/FC 9551) |
2858-A22 (w/FC 9551) |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240VAC, 12A to 8A (max) | |||
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 3.8A @ 100-120VAC (typical) | 6A @ 100-120VAC (typical) | 4.8A @ 100-120VAC (typical) | 8.1A @ 100-120VAC (typical) |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 2A @ 200-240VAC (typical) | 3A @ 200-240VAC (typical) | 2.4A @ 200-240VAC (typical) | 4A @ 200-240VAC (typical) |
| Thermal rating | 1405 BTU/hr. (max.) | 2714 BTU/hr. (max.) | 1790 BTU/hr. (max.) | 3574 BTU/hr. (max.) |
| Weight (max.) | 102 lb (46.2 kg) | 121 lb (54.9 kg) | 102 lb (46.2 kg) | 121 lb (54.9 kg) |
| Height | 10.2" (25.9 cm), fits into 6U space | |||
| Width | 19" IEC rack-compliant (17.6", 44.7 cm) | |||
| Depth | 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket | |||
| Operating temperature, altitude, and relative humidity | 10°C to 40°C (50°F to 104°F); at </= 3,050m (at </= 10,000) elevation; 20 to 80 percent relative humidity, non-condensing (28°C wet bulb temperature) | |||
| Nonoperating temperature and relative humidity | -40°C to 65°C (-40°F to 149°F); 10 to 95 percent relative humidity, non-condensing, in original container | |||
| Operating acoustic noise | 56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | |||
| Min. cabinet clearances | 10" (25.4 cm) front; 12" (30.5 cm) rear | |||
| Min. service clearances | 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet | |||
| Maximum altitude | 3050 m (10,000 ft.) | |||
| Environmental Specifications | N6070 | N6070 |
|---|---|---|
| Machine Type Model | 2858-A11 | 2858-A21 |
| Gateway Machine Type Model | 2858-A11 (w/ FC 9551) |
2858-A21 (w/ FC 9551) |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240VAC, 12A to 8A (max) | |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 4.8A @ 100-120VAC (typical) | 8.1A @ 100-120VAC (typical) |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 2.4A @ 200-240VAC (typical) | 4A @ 200-240VAC (typical) |
| Thermal rating | 1790 BTU/hr. (max.) | 3574 BTU/hr. (max.) |
| Weight (max.) | 102 lb (46.2 kg) | 121 lb (54.9 kg) |
| Height | 10.2" (25.9 cm), fits into 6U space | |
| Width | 19" IEC rack-compliant (17.6", 44.7 cm) | |
| Depth | 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket | |
| Operating temperature, altitude, and relative humidity | 10°C to 40°C (50°F to 104°F); at </= 3,050m (at </= 10,000) elevation; 20 to 80 percent relative humidity, non-condensing (28°C wet bulb temperature) | |
| Nonoperating temperature and relative humidity | -40°C to 65°C (-40°F to 149°F); 10 to 95 percent relative humidity, non-condensing, in original container | |
| Operating acoustic noise | 56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | |
| Min. cabinet clearances | 10" (25.4 cm) front; 12" (30.5 cm) rear | |
| Min. service clearances | 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet | |
| Maximum altitude | 3050 m (10,000 ft.) | |
| Regulations | |
| Filer safety | EN 60950:2002, CE, CSA 60950 and NRTL (UL) CB (all national deviations), EN60825-1:1994, IRAM, GOST-R |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |
Storage Expansion Specifications
| Storage Expansion Unit Disk Drive Support | |
|---|---|
| EXN4000 - 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm 2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm |
| EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB |
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 500 GB, 7,200 rpm; 1 TB |
| Storage Expansion Unit Specifications | |
|---|---|
| Disk Storage Expansion Units Supported | EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) EXN1000 SATA disk storage expansion unit (MTM 2861-001) Each with 14 low-profile slots for FC and SATA disk drives Support for Legacy Expansion Unit |
| Storage expansion unit interface | PCI-x or PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL) |
| Environmental specifications | |
|---|---|
| Power supply/cooling fans | Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
| AC power/max. current | 100 to 120VAC/4.4A; 200 to 240VAC/2.3A 100 to 120VAC/7A; 200-240VAC/3.5A; 50/60 Hz |
| Operating temperature maximum range | 10°C to 40°C (50°F to 104°F) |
| Recommended operating temperature range | 20°C to 25°C (68°F to 77°F) |
| Operating relative humidity range | 10 to 95 percent relative humidity, non-condensing 10 to 95 percent |
| Recommended operating relative humidity range | 40 to 55 percent non-condensing |
| Nonoperating temperature range | -40°C to 65°C (-40°F to 149°F) |
| Nonoperating relative humidity range | 10 to 95 percent relative humidity, non-condensing |
| Thermal rating | 1,215 BTU/hr (fully loaded disk storage expansion unit) |
| Operating acoustic noise | 56.4 dBA @ 1 m at 23°C, 5.64 bels @ 23°C |
| Dimensions (height/width/depth) | 3U EIA (5.25 in., 13.3 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.85 cm) |
| Weight | EXN4000 – 35.8 kg (78.8 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty EXN3000 – 110 lb (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty EXN1000 – 35 kg (77 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty |
| Regulations | |
|---|---|
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |