Skip to main content

IBM System Storage N6000 series

Highlights

Today’s business environment demands innovation and increasingly flawless execution. You have to manage and protect valuable data to enable business growth and success. Your IT operations have to evolve with the business while meeting budget, staffing and infrastructure limits. Virtualised computing requires networked storage systems supporting diverse data sets to unlock the full potential of virtualised servers.

With IBM N6000 series systems you can simultaneously meet your diverse needs – Storage Area Network (SAN) and Network Attached Storage (NAS), primary and secondary storage. And you get outstanding value: our flexible systems offer excellent performance and impressive scalability at a low total cost of ownership (TCO).

Common features

Hardware summary


Feature Benefits
Advanced Single Instance Storage (A-SIS)
Data ONTAP
Disk Sanitisation
FlexCache
FlexClone
FlexShare
FlexVol
MetroCluster
MultiStore
NearStore (near-line)
Operations Manager
Performance Acceleration Module
Protection Manager
Provisioning Manager
RAID-DP
SecureAdmin
Single Mailbox Recovery for Exchange (SMBR)
SnapDrive
SnapLock
SnapManager
SnapMirror
SnapMover
SnapRestore
Snapshot
SnapValidator
SnapVault
SyncMirror
System Manager

  N6040 N6040 N6060 N6060
Machine Type Model 2858-A10 2858-A20 2858-A12 2858-A22
Gateway Machine Type Model 2858-A10
(w/FC 9551)
2858-A20
(w/FC 9551)
2858-A12
(w/FC 9551)
2858-A22
(w/FC 9551)
Controller Configuration Single Dual (active/active) Single Dual (active/active)
Processors Speed and Type 2.4 GHz AMD Dual-core 64-bit Opteron
Number of Processors One Two Two Four
Random Access Memory (RAM) 4 GB 8 GB 8 GB 16 GB
Nonvolatile Memory 512 MB 1 GB 2 GB 4 GB
Integrated I/O Ports
FC Ports (Speed) Four (4-Gbps) Eight (4-Gbps) Four (4-Gbps) Eight (4-Gbps)
Ethernet Ports (Speed) Two (1-Gbps) Four (1-Gbps) Two (1-Gbps) Four (1-Gbps)
Storage Scalability
Maximum Number of FC Loops 10 10 10 10
Maximum Raw Capacity 420 TB 420 TB 672 TB 672 TB
Maximum Number of Disk Drives 420 420 672 672
Maximum Volume Size 16 TB 16 TB 16 TB 16 TB
Maximum Number of Volumes/LUNs 2048 2048 2048 2048
Maximum Number of Storage Enclosures 30 30 48 48
Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) 256
I/O Scalability
PCI-e Expansion Slots Four Eight Four Eight
Maximum number of FC Ports 20 40 20 40
Maximum number of Ethernet Ports 18 36 18 36
Maximum Number of Optional Adapters Four Eight Four Eight
Storage Expansion Unit Disk Drive Support
EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) 4-Gbps FC: 300 GB, 15,000 revolutions per minute (rpm); 450 GB, 15,000 rpm
2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
EXN3000 – Serial Attached SCSI (SAS) Disk Storage Expansion Unit (MTM 2857-003) SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
SATA: 500 GB, 7,200 rpm; 1 TB
EXN1000 SATA disk storage expansion unit (MTM 2861-001) SATA: 500 GB, 7,200 rpm; 1 TB
Maximum Number of Adapters Supported Per System (below - not to exceed Maximum Number of Optional Adapters)
1012 - Dual-Port GbE NIC (fibre) Four Eight Four Eight
1013 - Dual-Port GbE NIC (copper) Four Eight Four Eight
1014 - Dual-Port 4-Gbps FC Host Bus Adapter (HBA) Disk Four Eight Four Eight
1015 - Dual-Port 4-Gbps FC HBA Tape Four Eight Four Eight
1017 - Dual-Port 4-Gbps FC HBA Target Four Eight Four Eight
1021 - Dual-Port GbE iSCSI Target (fibre) Four Eight Four Eight
1023 - Quad-Port GbE NIC (copper) Four Eight Four Eight
1024 - Dual-Port SCSI Ultra320 HBA Tape Four Eight Four Eight
1026 - Dual-Port GbE NIC (copper) Four Eight Four Eight
1029 - Quad-Port 4-Gbps FC HBA - DISK Four Eight Four Eight
1030 - Quad port 4 Gbps FC Target Four Eight Four Eight
1031 - Dual-Port 10-GbE TCP/IP Offload Engine (TOE) NIC Four Eight Four Eight
1032 - Dual-Port MetroCluster VI HBA Three Six Three Six
1033 - SnapMirror Over FC HBA PCI-e Four Eight Four Eight
1035 - Quad-Port 4-Gbps FC HBA Tape/Disk Four Eight Four Eight
1036 - PCIe 2 port 8 GB FC Target HBA Four Eight Four Eight
1056 - Performance Acceleration Module (16 GB) Four Eight Four Eight
1057 - Performance Acceleration Module (512 GB) - - - -
1058 - Performance Acceleration Module (256 GB)* Two Four Two Four
1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** Four Eight Four Eight
1063 - Dual-port Fibre Channel over Ethernet (FCoE) adapter (optical) Four Eight Four Eight
1064 - Dual-port FCoE adapter (cooper) Four Eight Four Eight
1065 – Dual-port 10 Gbps Ethernet NIC card Four Eight Four Eight

* Corequisite: Performance Acceleration Module II software feature per filer/gateway. Requires ONTAP 7.3.2

** For use with the EXN3000 and QSFP-QSFP cabling

  N6070 N6070
Machine Type Model 2858-A11 2858-A21
Gateway Machine Type Model 2858-A11
(w/FC 9551)
2858-A21
(w/FC 9551)
Controller Configuration Single Dual (active/active)
Processors Speed and Type 2.4 GHz AMD Dual-core 64-bit Opteron
Number of Processors Two Four
RAM 16 GB 32 GB
Nonvolatile Memory 2 GB 4 GB
Integrated I/O Ports
FC Ports (Speed) Four (4-Gbps) Eight (4-Gbps)
Ethernet Ports (Speed) Two (1-Gbps) Four (1-Gbps)
Storage Scalability
Maximum Number of FC Loops 10 10
Maximum Raw Capacity 840 TB 840 TB
Maximum Number of Disk Drives 840 840
Maximum Volume Size 16 TB 16 TB
Maximum Number of Volumes/LUNs 2048 2048
Maximum Number of Storage Enclosures 60 60
Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) 256
I/O Scalability
PCI-e Expansion Slots Four Eight
Maximum number of FC Ports 20 40
Maximum number of Ethernet Ports 18 36
Maximum Number of Optional Adapters Four 8
Storage Expansion Unit Disk Drive Support
EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) 4-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
SATA: 500 GB, 7,200 rpm; 1 TB
EXN1000 SATA disk storage expansion unit (MTM 2861-001) SATA: 500 GB, 7,200 rpm; 1 TB
Maximum Number of Adapters Supported Per System (below - not to exceed Maximum Number of Optional Adapters)
1012 - Dual-Port GbE NIC (fibre) Four Eight
1013 - Dual-Port GbE NIC (copper) Four Eight
1014 - Dual-Port 4-Gbps FC HBA Disk Four Eight
1015 - Dual-Port 4-Gbps FC HBA Tape Four Eight
1017 - Dual-Port 4-Gbps FC HBA Target Four Eight
1021 - Dual-Port GbE iSCSI Target (fibre) Four Eight
1023 - Quad-Port GbE NIC (copper) Four Eight
1024 - Dual-Port SCSI Ultra320 HBA Tape Four Eight
1026 - Dual-Port GbE NIC (copper) Four Eight
1029 - Quad-Port 4-Gbps FC HBA - DISK Four Eight
1030 - Quad port 4 Gbps FC Target Four Eight
1031 - Dual-Port 10-GbE TOE NIC Four Eight
1032 - Dual-Port MetroCluster VI HBA Two Four
1033 - SnapMirror Over FC HBA PCI-e Four Eight
1035 - Quad-Port 4-Gbps FC HBA Tape/Disk Four Eight
1036 - PCIe 2 port 8 GB FC Target HBA Four Eight
1056 - Performance Acceleration Module (16 GB) Four Eight
1057 - Performance Acceleration Module (512 GB)* Two Four
1058 - Performance Acceleration Module (256 GB) - -
1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** Four Eight
1063 - Dual-port FCoE adapter (optical) Four Eight
1064 - Dual-port FCoE adapter (cooper) Four Eight
1065 – Dual-port 10 Gbps Ethernet NIC card Four Eight

* Corequisite: Performance Acceleration Module II software feature per filer/gateway. Requires ONTAP 7.3.2

** For use with the EXN3000 and QSFP-QSFP cabling

Environmental Specifications and Regulations for Appliance and Gateway Models

Environmental Specifications N6040 N6040 N6060 N6060
Machine Type Model 2858-A10 2858-A20 2858-A12 2858-A22
Gateway Machine Type Model 2858-A10
(w/FC 9551)
2858-A20
(w/FC 9551)
2858-A12
(w/FC 9551)
2858-A22
(w/FC 9551)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 100 to 240VAC, 12A to 8A (max)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 3.8A @ 100-120VAC (typical) 6A @ 100-120VAC (typical) 4.8A @ 100-120VAC (typical) 8.1A @ 100-120VAC (typical)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 2A @ 200-240VAC (typical) 3A @ 200-240VAC (typical) 2.4A @ 200-240VAC (typical) 4A @ 200-240VAC (typical)
Thermal rating 1405 BTU/hr. (max.) 2714 BTU/hr. (max.) 1790 BTU/hr. (max.) 3574 BTU/hr. (max.)
Weight (max.) 102 lb (46.2 kg) 121 lb (54.9 kg) 102 lb (46.2 kg) 121 lb (54.9 kg)
Height 10.2" (25.9 cm), fits into 6U space
Width 19" IEC rack-compliant (17.6", 44.7 cm)
Depth 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket
Operating temperature, altitude, and relative humidity 10°C to 40°C (50°F to 104°F); at </= 3,050m (at </= 10,000) elevation; 20 to 80 percent relative humidity, non-condensing (28°C wet bulb temperature)
Nonoperating temperature and relative humidity -40°C to 65°C (-40°F to 149°F); 10 to 95 percent relative humidity, non-condensing, in original container
Operating acoustic noise 56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level)
Min. cabinet clearances 10" (25.4 cm) front; 12" (30.5 cm) rear
Min. service clearances 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet
Maximum altitude 3050 m (10,000 ft.)
Environmental Specifications N6070 N6070
Machine Type Model 2858-A11 2858-A21
Gateway Machine Type Model 2858-A11
(w/ FC 9551)
2858-A21
(w/ FC 9551)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 100 to 240VAC, 12A to 8A (max)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 4.8A @ 100-120VAC (typical) 8.1A @ 100-120VAC (typical)
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 2.4A @ 200-240VAC (typical) 4A @ 200-240VAC (typical)
Thermal rating 1790 BTU/hr. (max.) 3574 BTU/hr. (max.)
Weight (max.) 102 lb (46.2 kg) 121 lb (54.9 kg)
Height 10.2" (25.9 cm), fits into 6U space
Width 19" IEC rack-compliant (17.6", 44.7 cm)
Depth 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket
Operating temperature, altitude, and relative humidity 10°C to 40°C (50°F to 104°F); at </= 3,050m (at </= 10,000) elevation; 20 to 80 percent relative humidity, non-condensing (28°C wet bulb temperature)
Nonoperating temperature and relative humidity -40°C to 65°C (-40°F to 149°F); 10 to 95 percent relative humidity, non-condensing, in original container
Operating acoustic noise 56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level)
Min. cabinet clearances 10" (25.4 cm) front; 12" (30.5 cm) rear
Min. service clearances 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet
Maximum altitude 3050 m (10,000 ft.)
Regulations
Filer safety EN 60950:2002, CE, CSA 60950 and NRTL (UL) CB (all national deviations), EN60825-1:1994, IRAM, GOST-R
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

Storage Expansion Specifications

Storage Expansion Unit Disk Drive Support
EXN4000 - 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) 4-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
2-Gbps FC: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) SAS: 300 GB, 15,000 rpm; 450 GB, 15,000 rpm
SATA: 500 GB, 7,200 rpm; 1 TB
EXN1000 SATA disk storage expansion unit (MTM 2861-001) SATA: 500 GB, 7,200 rpm; 1 TB
Storage Expansion Unit Specifications
Disk Storage Expansion Units Supported EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004)
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003)
EXN1000 SATA disk storage expansion unit (MTM 2861-001)
Each with 14 low-profile slots for FC and SATA disk drives
Support for Legacy Expansion Unit
Storage expansion unit interface PCI-x or PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL)
Environmental specifications
Power supply/cooling fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
AC power/max. current 100 to 120VAC/4.4A; 200 to 240VAC/2.3A 100 to 120VAC/7A; 200-240VAC/3.5A; 50/60 Hz
Operating temperature maximum range 10°C to 40°C (50°F to 104°F)
Recommended operating temperature range 20°C to 25°C (68°F to 77°F)
Operating relative humidity range 10 to 95 percent relative humidity, non-condensing 10 to 95 percent
Recommended operating relative humidity range 40 to 55 percent non-condensing
Nonoperating temperature range -40°C to 65°C (-40°F to 149°F)
Nonoperating relative humidity range 10 to 95 percent relative humidity, non-condensing
Thermal rating 1,215 BTU/hr (fully loaded disk storage expansion unit)
Operating acoustic noise 56.4 dBA @ 1 m at 23°C, 5.64 bels @ 23°C
Dimensions (height/width/depth) 3U EIA (5.25 in., 13.3 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.85 cm)
Weight EXN4000 – 35.8 kg (78.8 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty
EXN3000 – 110 lb (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty
EXN1000 – 35 kg (77 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty
Regulations
Disk shelf safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998

We're here to help

Easy ways to get the answers you need.


or call IBM at
0870 539 0390