| Specifications |
 |
| |
 |
N7700 |
 |
N7900 |
 |
| Machine type model |
 |
2866-A21 |
 |
2867-A21 |
 |
| Gateway Machine Type Model |
 |
2866-A21 (w/ FC 9551) |
 |
2867-A21 (w/ FC 9551) |
 |
| Controller Configuration |
 |
Dual (active/active) |
 |
Dual (active/active) |
 |
| Processors Speed and Type |
 |
2.6 GHz AMD Opteron |
 |
2.6 GHz AMD Dual Core Opteron |
 |
| Number of Processors |
 |
4 |
 |
8 |
 |
| Random Access Memory (RAM) |
 |
32 GB |
 |
64 GB |
 |
| Nonvolatile Memory |
 |
1 GB |
 |
4 GB |
|
 |
 |
 |
 |
| Integrated I/O Ports |
 |
| FC Ports/Speed |
 |
16 (4-Gbps) |
 |
16 (4-Gbps) |
 |
| Ethernet Ports/Speed |
 |
12 (1-Gbps) |
 |
12 (1-Gbps) |
|
 |
 |
 |
 |
| Storage Scalability |
 |
| Maximum Number of FC Loops |
 |
10 |
 |
14 |
 |
| Maximum Raw Capacity |
 |
840 GB |
 |
1176 GB |
 |
| Maximum Number of Disk Drives |
 |
840 |
 |
1176 |
 |
| Maximum Volume Size |
 |
16 TB |
 |
16 TB |
 |
| Maximum Number of Volumes/LUNs |
 |
2048 |
 |
2048 |
 |
| Maximum Number of Storage Enclosures |
 |
60 |
 |
84 |
 |
| Disk Expansion Units Supported |
 |
EXN4000 - FC Disk Storage Expansion Unit
EXN1000 - SATA Disk Storage Expansion |
 |
| EXN1000 - SATA Disk Storage Expansion |
|
 |
 |
 |
 |
| I/O scalability |
 |
| PCI-Express (PCI-e) Expansion Slots |
 |
10 |
 |
10 |
 |
| PCI-x Expansion Slots |
 |
6 |
 |
6 |
 |
| Maximum Number FC ports |
 |
56 |
 |
56 |
 |
| Maximum Number of Ethernet Ports |
 |
52 |
 |
52 |
|
 |
 |
 |
 |
| Maximum Number of Adapters Supported Per System (below – not to exceed Maximum Number of Optional Adapters) |
 |
| 1007 - Quad-Port GbE NIC (copper) |
 |
4 |
 |
4 |
 |
1008 - Single-Port 10-GbE TCP-IP
Offload Engine (TOE) NIC |
 |
4 |
 |
4 |
 |
| 1009 - Quad-Port GbE TOE NIC (copper) |
 |
4 |
 |
4 |
 |
| 1010 - Dual-Port iSCSI Target NIC (copper) |
 |
6 |
 |
6 |
 |
| 1011 - Dual-Port iSCSI Target NIC (fibre) |
 |
6 |
 |
10 |
 |
| 1012 - Dual-Port GbE NIC (fibre) |
 |
10 |
 |
10 |
 |
| 1013 - Dual-Port GbE NIC (copper) |
 |
10 |
 |
10 |
 |
1014 - Dual-Port 4-Gbps FC Host Bus
Adapter (HBA) Disk |
 |
10 |
 |
10 |
 |
| 1015 - Dual-Port 4-Gbps FC HBA Tape |
 |
6 |
 |
6 |
 |
1016 - SCSI Low Voltage Differential
(LVD) Tape Adapter |
 |
8 |
 |
6 |
 |
| 1017 - Dual-Port 4-Gbps FC HBA Target |
 |
8 |
 |
N/A |
 |
| 1021 - Dual-Port GbE iSCSI Target (fibre) |
 |
10 |
 |
10 |
 |
| 1022 - Quad-Port GbE TOE NIC (copper) |
 |
10 |
 |
10 |
 |
| 1023 - Quad-Port GbE NIC (copper) |
 |
10 |
 |
10 |
 |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape |
 |
6 |
 |
6 |
 |
| 1026 - Dual-Port GbE NIC (copper) |
 |
10 |
 |
10 |
 |
| 1029 - Quad-Port 4-Gbps FC HBA - DISK |
 |
10 |
 |
10 |
 |
| 1030 - Quad port 4-Gbps FC Target |
 |
8 |
 |
8 |
 |
| 1031 - Dual-Port 10-GbE TOE NIC |
 |
10 |
 |
10 |
 |
| 1032 - Dual-Port MetroCluster VI HBA |
 |
4 |
 |
4 |
 |
| 1033 - SnapMirror Over FC HBA PCI-e |
 |
4 |
 |
4 |
 |
| 1034 - SnapMirror Over FC HBA PCI-x |
 |
4 |
 |
4 |
 |
| 1035 - Quad-Port 4-GBPS FC HBA Tape/Disk |
 |
10 |
 |
10 |
 |
| 1036 - PCIe 2 port 8 Gb FC Target HBA |
 |
10 |
 |
10 |
 |
| 1056 - FlexScale 16GB PCI-e Accelerator Adapter |
 |
8 |
 |
10 |
|
 |
 |
Environmental Specifications for N7000 series
 |
 |
| Environmental specifications |
 |
|
 |
|
 |
| |
 |
N7700 |
 |
N7900 |
 |
| Machine Type Model |
 |
2866-A21 |
 |
2867-A21 |
 |
| Gateway Machine Type Model |
 |
2866-A21 (w/ FC 9551) |
 |
2867-A21 (w/ FC 9551) |
 |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) |
 |
100 to 240 VAC, 11 A to 5.5 A (typical)
24 A (max.) @ 100 VAC
200 to 240 VAC, 9 A to 5.5 A (typical)
12 A (max.) @ 200 VAC
|
 |
 |
| Thermal rating |
 |
6142 BTU/hr. |
 |
| Weight (max.) |
 |
242 lb (109.6 kg) |
 |
| Height |
 |
20.8" (52.6 cm), fits into 12U space |
 |
| Width |
 |
19" IEC rack-compliant (17.6", 44.6 cm) |
 |
| Depth |
 |
27.4" (69.5 cm), 30.8" (78.2 cm) with cable management bracket |
 |
| Operating temperature, altitude and relative humidity |
 |
10°C to 40°C (50°F to 104°F); at </= 3,050m (at </= 10,000) elevation; 20 percent to 80 percent relative humidity, non-condensing (28°C wet bulb temperature) |
 |
| Non-operating temperature and relative humidity |
 |
-40°C to 65°C (-40°F to 149°F); 10 percent to 95 percent relative humidity, non-condensing, in original container |
 |
| Operating acoustic noise |
 |
49 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
 |
| Min. cabinet clearances |
 |
6" (15.3 cm) front; 12" (30.5 cm) rear |
 |
| Min. service clearances |
 |
25" (63.5 cm) from front of cabinet; 40" (102 cm) from rear of cabinet |
 |
| Maximum altitude |
 |
2133 m (7,000 ft.) |
|
 |
 |
Specifications for N6000 series
 |
 |
| Specifications |
 |
| |
 |
N6040 |
 |
N6040 |
 |
N6060 |
 |
N6060 |
 |
| Machine type model |
 |
2858-A10 |
 |
2858-A20 |
 |
2858-A12 |
 |
2858-A22 |
 |
| Gateway Machine Type Model |
 |
2858-A10
(w/ FC 9551) |
 |
2858-A20
(w/ FC 9551) |
 |
2858-A12
(w/ FC 9551) |
 |
2858-A22
(w/ FC 9551) |
 |
| Controller Configuration |
 |
Single |
 |
Dual (active/active) |
 |
Single |
 |
Dual (active/active) |
 |
| Processors Speed and Type |
 |
2.4 GHz AMD Dual-core 64-bit Opteron |
 |
| Number of Processors |
 |
1 |
 |
2 |
 |
2 |
 |
4 |
 |
| RAM |
 |
4 GB |
 |
8 GB |
 |
8 GB |
 |
16 GB |
 |
| Nonvolatile Memory |
 |
512 MB |
 |
1 GB |
 |
2 GB |
 |
4 GB |
|
 |
 |
 |
 |
| Integrated I/O Ports |
 |
| FC Ports (Speed) |
 |
4 (4-Gbps) |
 |
8 (4-Gbps) |
 |
4 (4-Gbps) |
 |
8 (4-Gbps) |
 |
| Ethernet Ports (Speed) |
 |
2 (1-Gbps) |
 |
4 (1-Gbps) |
 |
2 (1-Gbps) |
 |
4 (1-Gbps) |
|
 |
 |
 |
 |
| Storage Scalability |
 |
| Maximum Number of FC Loops |
 |
10 |
 |
10 |
 |
10 |
 |
10 |
 |
| Maximum Raw Capacity |
 |
420 TB |
 |
420 TB |
 |
672 TB |
 |
672 TB |
 |
| Maximum Number of Disk Drives |
 |
420 |
 |
420 |
 |
672 |
 |
672 |
 |
| Maximum Volume Size |
 |
16 TB |
 |
16 TB |
 |
16 TB |
 |
16 TB |
 |
| Maximum Number of Volumes/LUNs |
 |
2048 |
 |
2048 |
 |
2048 |
 |
2048 |
 |
| Maximum Number of Storage Enclosures |
 |
30 |
 |
30 |
 |
48 |
 |
48 |
 |
| Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) |
 |
256 |
|
 |
 |
 |
 |
| I/O Scalability |
 |
| PCI-e Expansion Slots |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| Maximum Number FC Ports |
 |
20 |
 |
40 |
 |
20 |
 |
40 |
 |
| Maximum Number of Ethernet Ports |
 |
18 |
 |
36 |
 |
18 |
 |
36 |
 |
| Maximum Number of Optional Adapters |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
|
 |
 |
 |
 |
| Storage Expansion Unit Disk Drive Support |
 |
EXN4000 – 4-Gbps
FC Disk Storage Expansion Unit (MTM 2863-004) |
 |
4-Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm
2-Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm |
 |
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) |
 |
SATA: 500 GB, 7,200 rpm; 750 GB, 7,200 rpm, 1 TB |
|
 |
 |
 |
 |
| Maximum Number of Adapters Supported Per System (below – not to exceed Maximum Number of Optional Adapters) |
 |
| 1012 - Dual-Port GbE NIC (fibre) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1013 - Dual-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1014 - Dual-Port 4-Gbps FC HBA Disk |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1015 - Dual-Port 4-Gbps FC HBA Tape |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1017 - Dual-Port 4-Gbps FC HBA Target |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1021 - Dual-Port GbE iSCSI Target (fibre) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1023 - Quad-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1026 - Dual-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1029 - Quad-Port 4-Gbps FC HBA - DISK |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1031 - Dual-Port 10-GbE TOE NIC |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1032 - Dual-Port MetroCluster VI HBA |
 |
3 |
 |
6 |
 |
3 |
 |
6 |
 |
| 1033 - SnapMirror Over FC HBA PCI-e |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1035 - Quad-Port 4-Gbps FC HBA Tape/Disk |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1036 - PCIe 2 port 8 Gb FC Target HBA |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
 |
| 1056 - Performance Acceleration Module (16 GB) |
 |
4 |
 |
8 |
 |
4 |
 |
8 |
|
 |
 |
 |
 |
| Specifications |
 |
| |
 |
N6070 |
 |
N6070 |
 |
| Machine Type Model |
 |
2858-A11 |
 |
2858-A21 |
 |
| Gateway Machine Type Model |
 |
2858-A11
(w/ FC 9551) |
 |
2858-A21
(w/ FC 9551) |
 |
| Controller Configuration |
 |
Single |
 |
Dual (active/active) |
 |
| Processors Speed and Type |
 |
2.4 GHz AMD Dual-core 64-bit Opteron |
 |
| Number of Processors |
 |
2 |
 |
4 |
 |
| RAM |
 |
16 GB |
 |
32 GB |
 |
| Nonvolatile Memory |
 |
2 GB |
 |
4 GB |
|
 |
 |
 |
 |
| Integrated I/O Ports |
 |
| FC Ports (Speed) |
 |
4 (4-Gbps) |
 |
8 (4-Gbps) |
 |
| Ethernet ports (Speed) |
 |
2 (1-Gbps) |
 |
4 (1-Gbps) |
|
 |
 |
 |
 |
| Storage Scalability |
 |
| Maximum Number of FC Loops |
 |
10 |
 |
10 |
 |
| Maximum Raw Capacity |
 |
840 TB |
 |
840 TB |
 |
| Maximum Number of Disk Drives |
 |
840 |
 |
840 |
 |
| Maximum Volume Size |
 |
16 TB |
 |
16 TB |
 |
| Maximum Number of Volumes/LUNs |
 |
2048 |
 |
2048 |
 |
| Maximum Number of Storage Enclosures |
 |
60 |
 |
60 |
 |
| Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) |
 |
256 |
|
 |
 |
 |
 |
| I/O Scalability |
 |
| PCI-e Expansion Slots |
 |
4 |
 |
8 |
 |
| Maximum Number FC Ports |
 |
20 |
 |
40 |
 |
| Maximum Number of Ethernet Ports |
 |
18 |
 |
36 |
 |
| Maximum Number of Optional Adapters |
 |
4 |
 |
8 |
|
 |
 |
 |
 |
| Storage Expansion Unit Disk Drive Support |
 |
| EXN4000 – 4-Gbps FC Disk Storage Expansion Unit (MTM 2863-004) |
 |
4-Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm
2-Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm |
 |
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) |
 |
SATA: 500 GB, 7,200 rpm; 750 GB, 7,200 rpm, 1 TB |
|
 |
 |
 |
 |
| Maximum Number of Adapters Supported Per System (below—not to exceed Maximum Number of Optional Adapters) |
 |
| 1012 - Dual-Port GbE NIC (fibre) |
 |
4 |
 |
8 |
 |
| 1013 - Dual-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
| 1014 - Dual-Port 4-Gbps FC HBA Disk |
 |
4 |
 |
8 |
 |
| 1015 - Dual-Port 4-Gbps FC HBA Tape |
 |
4 |
 |
8 |
 |
| 1017 - Dual-Port 4-Gbps FC HBA Target |
 |
4 |
 |
8 |
 |
| 1021 - Dual-Port GbE iSCSI Target (fibre) |
 |
4 |
 |
8 |
 |
| 1023 - Quad-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape |
 |
4 |
 |
8 |
 |
| 1026 - Dual-Port GbE NIC (copper) |
 |
4 |
 |
8 |
 |
| 1029 - Quad-Port 4-Gbps FC HBA - DISK |
 |
4 |
 |
8 |
 |
| 1031 - Dual-Port 10-GbE TOE NIC |
 |
4 |
 |
8 |
 |
| 1032 - Dual-Port MetroCluster VI HBA |
 |
3 |
 |
6 |
 |
| 1033 - SnapMirror Over FC HBA PCI-e |
 |
4 |
 |
8 |
 |
| 1035 - Quad-Port 4-Gbps FC HBA Tape/Disk |
 |
4 |
 |
8 |
 |
| 1036 - PCIe 2 port 8 Gb FC Target HBA |
 |
4 |
 |
8 |
 |
| 1056 - Performance Acceleration Module (16 GB) |
 |
4 |
 |
8 |
|
 |
 |
Environmental Specifications and Regulations for N6000 series
 |
 |
| Environmental specifications |
 |
|
 |
|
 |
|
 |
|
 |
| |
 |
N6040 |
 |
N6040 |
 |
N6060 |
 |
N6060 |
 |
| Machine Type Model |
 |
2858-A10 |
 |
2858-A20 |
 |
2858-A12 |
 |
2858-A22 |
 |
| Gateway Machine Type Model |
 |
2858-A10
(w/ FC 9551) |
 |
2858-A20
(w/ FC 9551) |
 |
2858-A12
(w/ FC 9551) |
 |
2858-A22
(w/ FC 9551) |
 |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) |
 |
100 to 240 VAC, 12 A to 8 A (max) |
 |
3.8 A @ 100 - 120 VAC (typical) |
 |
6 A @ 100 - 120 VAC (typical)> |
 |
4.8 A @ 100 - 120 VAC (typical) |
 |
8.1 A @ 100 - 120 VAC (typical) |
 |
2 A @ 200 - 240 VAC (typical) |
 |
3 A @ 200 - 240 VAC (typical) |
 |
2.4 A @ 200 - 240 VAC (typical) |
 |
4 A @ 200 - 240 VAC (typical) |
 |
| Thermal rating |
 |
1405 BTU/hr. (max) |
 |
2714 BTU/hr. (max) |
 |
1790 BTU/hr. (max) |
 |
3574 BTU/hr. (max) |
 |
| Weight (max.) |
 |
102 lb (46.2 kg) |
 |
121 lb (54.9 kg) |
 |
102 lb (46.2 kg) |
 |
121 lb (54.9 kg) |
 |
| Height |
 |
10.2" (25.9 cm), fits into 6U space |
 |
| Width |
 |
19" IEC rack-compliant (17.6", 44.7 cm) |
 |
| Depth |
 |
24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket |
 |
| Operating temperature, altitude, and relative humidity |
 |
10°C to 40°C (50°F to 104°F); at </= 3,050 m (at </= 10,000) elevation; 20 percent to 80 percent relative humidity, non-condensing (28°C wet bulb temperature) |
 |
| Non-operating temperature and relative humidity |
 |
-40°C to 65°C (-40°F to 149°F); 10 percent to 95 percent relative humidity, non-condensing, in original container |
 |
| Operating acoustic noise |
 |
56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
 |
| Min. cabinet clearances |
 |
10" (25.4 cm) front; 12" (30.5 cm) rear |
 |
| Min. service clearances |
 |
30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet |
 |
| Maximum altitude |
 |
3050 m (10,000 ft.) |
|
 |
 |
 |
 |
| Environmental specifications |
 |
|
 |
|
 |
| |
 |
N6070 |
 |
N6070 |
 |
| Machine Type Model |
 |
2858-A11 |
 |
2858-A21 |
 |
| Gateway Machine Type Model |
 |
2858-A11
(w/ FC 9551) |
 |
2858-A11
(w/ FC 9551) |
 |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) |
 |
100 to 240 VAC, 12 A to 8 A (max) |
 |
4.8 A @ 100 - 120 VAC (typical)
2.4A @ 200 - 240 VAC (typical) |
 |
8.1 A @ 100 - 120 VAC (typical)
4 A @ 200 - 240 VAC (typical) |
 |
 |
| |
 |
|
 |
| Thermal rating |
 |
1790 BTU/hr. (max) |
 |
3574 BTU/hr. (max) |
 |
| Weight (max.) |
 |
102 lb (46.2 kg) |
 |
121 lb (54.9 kg) |
 |
| Height |
 |
10.2" (25.9 cm), fits into 6U space |
 |
| Width |
 |
19" IEC rack-compliant (17.6", 44.7 cm) |
 |
| Depth |
 |
24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket |
 |
| Operating temperature, altitude and relative humidity |
 |
10°C to 40°C (50°F to 104°F); at </= 3,050 m (at </= 10,000) elevation; 20 percent to 80 percent relative humidity, non-condensing (28°C wet bulb temperature) |
 |
| Non-operating temperature and relative humidity |
 |
-40°C to 65°C (-40°F to 149°F); 10 percent to 95 percent relative humidity, non-condensing, in original container |
 |
| Operating acoustic noise |
 |
56 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
 |
| Min. cabinet clearances |
 |
10" (25.4 cm) front; 12" (30.5 cm) rear |
 |
| Min. service clearances |
 |
30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet |
 |
| Maximum altitude |
 |
3050 m (10,000 ft.) |
|
 |
 |
 |
 |
|
 |
 |
 |
 |
| Filer safety |
 |
EN 60950:2002, CE, CSA 60950 and NRTL (UL) CB (all national deviations), EN60825-1:1994, IRAM, GOST-R |
|
 |
 |
 |
 |
| Disk shelf safety |
 |
UL/C-UL; CE |
|
 |
 |
 |
 |
| Emissions |
 |
FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
|
 |
 |
 |
 |
| Immunity |
 |
EN 55024:1998 |
|
 |
 |
 |
 |
| Storage subsystem support specifications |
|
 |
 |
 |
 |
| Storage interface/data rate |
 |
PCI-Based FC Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4 Gbps |
|
 |
 |
 |
 |
|
 |
 |
 |
 |
 |
Storage Expansion Unit Disk Drive Support |
 |
 |
 |
 |
| EXN4000 - 4 Gbps FC Disk Storage Expansion Unit (MTM 2863-004) |
 |
4 Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm
2 Gbps FC: 300 GB, 10,000, 15,000 rpm; 450GB, 15,000 rpm |
|
 |
 |
 |
 |
| EXN1000 SATA disk storage expansion unit (MTM 2861-001) |
 |
SATA: 500 GB, 7,200 rpm; 750 GB, 7,200 rpm, 1 TB |
|
 |
 |
 |
 |
| Storage Expansion Unit Specifications |
 |
| Disk storage expansion units supported |
 |
EXN4000 - 4 Gbps FC Disk Storage Expansion Unit (MTM 2863-004)
EXN1000 SATA disk storage expansion unit (MTM 2861-001)
Each with 14 low-profile slots for FC and SATA disk drives
Legacy Support for Expansion Unit |
 |
| Disk drive storage shelf interface |
 |
PCI-x or PCI-e-based FC-AL |
|
 |
 |
 |
 |
| Environmental specifications |
 |
| Power supply/cooling fans |
 |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) |
 |
| AC power/max. current |
 |
100 to 120 VAC/4.4 A; 200 to 240 VAC/2.3 A 100 to 120 VAC/7 A; 200 - 240 VAC/3.5 A; 50/60 Hz |
 |
| Operating temperature maximum range |
 |
10°C to 40°C (50°F to 104°F) |
 |
| Recommended operating temperature range |
 |
20°C to 25°C (68°F to 77°F) |
 |
| Operating relative humidity range |
 |
10 percent to 95 percent relative humidity, non-condensing 10 percent to 95 percent |
 |
| Recommended operating relative humidity range |
 |
40 percent to 55 percent non-condensing |
 |
| Non-operating temperature range |
 |
-40°C to 65°C (-40°F to 149°F) |
 |
| Non-operating relative humidity range |
 |
10 percent to 95 percent relative humidity, non-condensing |
 |
| Thermal rating |
 |
1,215 Btu/hr (fully loaded disk storage expansion unit) |
 |
| Operating acoustic noise |
 |
56.4 dBA @ 1 m at 23°C, 5.64 bels @ 23°C |
 |
| Dimensions (height/width/depth) |
 |
3U EIA (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
 |
| Weight |
 |
EXN4000 - 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty
EXN1000 - 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty |
|
 |
 |
 |
 |
| Regulations |
 |
| Disk shelf safety |
 |
UL/C-UL; CE |
 |
| Emissions |
 |
FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
 |
| Immunity |
 |
EN 55024:1998 |
|
 |
 |
For N series tape drive support (refer to interoperability matrix on IBM Web site)
 |
 |
| N series Gateway supported backup methods |
|
 |
 |
 |
 |
| Disk-based backup |
 |
SnapVault, SnapMirror |
|
 |
 |
 |
 |
| Host-based backup |
 |
NDMP/NFS/CIFS/iSCSI |
|
 |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
 |


| |
 |
|
A product guide comparing all of IBM System Storage products
|
|
 |
|
|
|
|