| N7950T | |
| Machine type model | 2867-E22 |
| Gateway machine type model | 2867-E22 (with Fibre Channel 9551) |
| Controller configuration | Dual (active/active) |
| Processors speed and type | 2.93 GHz Intel 6-core |
| Number of processors | 24 |
| Random access memory | 192 GB1 |
| Nonvolatile memory | 8 GB |
| Integrated I/O ports | |
| Fibre Channel ports/speed | 8 (8-Gbps) |
| SAS ports/speed (requires FC1080) | 0-24 (6 Gbps) |
| Ethernet ports/speed | 8 (10-Gbps), 4 (1 Gbps) |
| Storage scalability | |
| Maximum number of Fibre Channel loops | 14 |
| Maximum number of SAS stacks | 10 |
| Maximum raw capacity | 4,320 TB |
| Maximum number of disk drives | 1,440 |
| Maximum volume size | 100 TB |
| Maximum size of volumes/LUNs | 4096 |
| Maximum number of SAN Hosts | Up to 512 hosts per HA pair Up to 24 directly connected servers per HA pair |
| Maximum number of storage enclosures | 84 |
| Disk expansion units supported | EXN4000 - Fibre Channel (FC) Disk Storage Expansion Unit: 4-Gbps FC: 300 GB, 450 GB, 600 GB (15k RPM) EXN3500 - SAS Disk Storage (SFF) Expansion Unit: SAS: 450 GB, 600 GB (10k RPM) EXN3000 - SAS Disk Storage Expansion Unit: SAS: 300 GB, 450 GB, 600 GB (15k RPM); SATA: 1 TB, 2 TB, 3 TB (7.2k RPM), 100 GB SSD EXN1000 - SATA Disk Storage Expansion Unit: SATA: 1 TB, 2 TB (7.2k RPM) |
| I/O scalability | |
| PCI-Express (PCI-e) expansion slots | 24 |
| PCI-x expansion slots | 6 |
| Maximum number of Fibre Channel ports | 128 |
| Maximum number of Ethernet ports | 100 |
| Maximum number of SAS ports | 72 |
| Maximum number of adapters supported per system (below - not to exceed maximum number of optional adapters) | |
| 1012 - Dual-Port GbE NIC (fibre) | 24 |
| 1014 - Dual-Port 4-Gbps Fibre Channel HBA Disk | 24 |
| 1015 - Dual-Port 4-Gbps Fibre Channel HBA Tape | 16 |
| 1028 - Quad Port GbE (copper) | 12 |
| 1029 - Quad-Port 4-Gbps Fibre Channel HBA - Disk | 24 |
| 1030 - Quad-Port 4-Gbps Fibre Channel Target | 12 |
| 1036 - PCIe 2 port 8 Gb Fibre Channel Target HBA | 24 |
| 1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** | 12 |
| 1063 - Dual-port FCoE adapter (optical) | 24 |
| 1064 - Dual-port FCoE adapter (cooper) | 24 |
| 1066 - MetroCluster VI Fibre Channel HBA 8Gb | 2 |
| 1067 - SnapMirror over Fibre Channel HBA 8Gb | 4 |
| 1071 - Flash Cache II 512Gb | 32 |
| 1072 - Flash Cache II 1Tb | 16 |
| 1078 - Dual-Port 10 GbE NIC, SFP+ | 16 |
| 1079 - Quad-Port 8 Gb Fibre Channel HBA | 6 |
| 1080 - Quad-Port 6 Gb SAS HBA | 6 |
| 2013 - SFP+ 10 GbE - Embedded NIC | 8 |
| 2014 - SFP+ Optical Module for 1078 | 32 |
| Warranty | 3 years for hardware and licensed software, CRU and Onsite service, Next Business Day 9×5, service upgrades available |
**For use with the EXN3000/3500 and QSFP-QSFP cabling
1 192 GB of physical memory; actual memory allocated depends on the Data ONTAP release in use
| Environmental specifications | |
|---|---|
| N7950T | |
| Machine type model | 2867-E22 |
| Gateway machine type model | 2867-E22 (with Fibre Channel 9551) |
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 120 V ac, 6.9 A (typical), 9.6 A (maximum) @ 100 V ac 200 to 240 V ac, 3.5 A (typical), 4.7 A (maximum) @ 200 V ac |
| Thermal rating | 6486 BTU/hr (max), 4540 BTU/hr (typical) |
| Weight (maximum) | 260.2 lbs (118 kg) |
| Height | 20.64 in. (52.42 cm), fits into 12U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.6 cm) |
| Depth | 24 in. (61 cm), 29 in. (73.66 cm) with cable management bracket |
| Operating temperature, altitude, and relative humidity | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Nonoperating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Minimum cabinet clearances | 15.2 cm (6 in.) in front, 30.5 cm (12 in.) in rear |
| Minimum service clearances | 25 in. (63.5 cm) from front of cabinet; 40 in. (102 cm) from rear of cabinet |
| Maximum altitude | 2133 m (7,000 ft.) |
| Regulations | |
|---|---|
| Filer safety | EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition), CB (all national deviations), EN 60825-1:2007, IRAM, GOST-R |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI |
| Immunity | EN 55024:1998 +A1:2001 +A2:2003 |
| Storage expansion unit disk drive support | |
|---|---|
| EXN4000 - 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | FC: 300 GB, 450 GB, 600 GB (15k RPM) |
| EXN3500 – SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) | SAS SFF: 450 GB, 600 GB (10k RPM) |
| EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB (15k RPM) SATA: 1 TB, 2 TB, 3 TB (7.2k RPM); 100 GB SSD |
| EXN1000 SATA Disk Storage Expansion Unit (MTM 2861-001) | SATA: 1 TB, 2 TB (7.2k RPM) |
| Storage expansion unit specifications | |
| Disk storage expansion units supported | EXN4000: 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) with 14 low-profile slots for fibre channel disk drives EXN3500: SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) with 24 SFF slots for SAS SFF disk drives EXN3000: SAS Disk Storage Expansion Unit (MTM 2857-003) with 24 slots for SAS disk drives EXN1000: SATA Disk storage expansion unit (MTM 2861-001) with 14 low-profile slots for SATA disk drives Legacy Support for Expansion Units |
| Disk drive storage shelf interface | PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL) or Serial attached SCSI (SAS) |
| Environmental specifications | |
| Power supply/cooling fans | EXN3000: Dual (SATA) or Quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) EXN1000, EXN3500, EXN4000: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) |
| AC power/ maximum current | 100 to 120 V ac/4.4 A; 200 to 240 V ac/2.3 A 100 to 120 V ac/7 A; 200 to 240 V ac/3.5 A; 50/60 Hz |
| Operating temperature maximum range | 10°C to 40°C (50°F to 104°F) |
| Recommended operating temperature range | 20°C to 25°C (68°F to 77°F) |
| Operating relative humidity range | 10% to 95% relative humidity, noncondensing 10% to 95% |
| Recommended operating relative humidity range | 40% to 55% noncondensing |
| Nonoperating temperature range | −40°C to 65°C (−40°F to 149°F) |
| Nonoperating relative humidity range | 10% to 95% relative humidity, noncondensing |
| Thermal rating | 1,215 Btu/hr (fully loaded disk storage expansion unit) |
| Operating acoustic noise | 56.4 dBA @ 1m at 23°C, 5.64 bels @ 23°C |
| Dimensions (height/width/depth) | EXN4000 and EXN1000 3U EIA (5.25 in., 13.3 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.8 cm) EXN3500 2U EIA (3.4 in., 8.5 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.8 cm) EXN3000 4U EIA (6.9 in., 17.49 cm)/19 in. IEC rack-compliant (17.7 in., 44.87 cm)/25.7 in. (65.35 cm) |
| Weight | EXN4000 - 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty EXN3500 - 49 lbs (22.2 kg) fully loaded with disk drives, 34.6 lbs (15.7 kb) empty EXN3000 - 110 lbs (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty EXN1000 - 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty |
| Regulations | |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |
| Operating system | Data ONTAP™ 7.2.5 or later |
|---|---|
| Operating system support | Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Sun Solaris, IBM AIX, HP-UX, Macintosh OS, ESX. Linux, VMware. |
| Standard software features | Integrated automatic RAID manager, including RAID-DP, Snapshot, Fast Boot, Telnet, email alerts, NIS, DNS, SNMP, SecureAdmin, FlexVol, FlexShare, SSH, Maintenance Center, Network Data Management Protocol (NDMP) |
| Network protocol support | NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, VLD, FTP, HTTP 1.0, HTTP 1.1 Virtual Hosts |
| SAN protocol support | Fibre Channel Protocol (FCP), FCoE for SCSI (2 Gb and 4 Gb); fabric-attached and direct-attached; iSCSI |
| Optional licensed functions | NFS, CIFS, HTTP, Fibre Channel Protocol (FCP), iSCSI Protocol, FCoE, FlexCache, FlexClone , FlexScale, MultiStore , Clustered Failover (CFO), SnapMirror , SnapRestore , Single Mailbox Recovery for Exchange, SnapManager for Exchange, SnapManager for SQL Server, SnapManager for Oracle, SnapManager for SAP , SnapManager for Microsoft Office SharePoint (SMSP), SnapManager for Virtual Infrastructure, SnapManager for Hyper-V, SnapVault, SnapMover, SyncMirror, MetroCluster, NearStore, SnapValidator, SnapDrive for Windows, SnapDrive for UNIX, SnapDrive for AIX, SnapDrive for HP-UX, SnapDrive for Linux, AIX multipathing, Operations Manager, Disk Sanitization, Deduplication, Protection Manager, Provisioning Manager |
| Hardware features | Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19 in. rack-mount enclosure, optional 220 V 42U 19 in. system cabinet |
| Maximum RAID group sizes | RAID 6 (RAID-DP) Fibre Channel - 28 (26 data disks plus 2 parity disks), SATA - 16 (14 data disks plus 2 parity disks) RAID 4 Fibre Channel - 14 (13 data disks plus 1 parity disk), SATA - 7 (6 data disks plus 1 parity disk) RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror) |
Maximum capacity is derived based on the type, size, and number of the drives. Maximum capacity and volume size are calculated using Base10 arithmetic (i.e., 1 TB = 1,000,000,000,000 bytes).