| N6220 | N6220 | N6220 | N6220 | N6250 | N6250 | N6270 | N6270 | N6270 | |
|---|---|---|---|---|---|---|---|---|---|
| Machine type model | 2858 -C15 |
2658 -C25 |
2858 -E15 |
2858 -E25 |
2858 -E16 |
2858 -E26 |
2858 -C22 |
2858 -E12 |
2858 -E22 |
| Gateway machine type model | 2858 -C15 (with feature code 9551) |
2658 -C25 (with feature code 9551) |
2858 -E15 (with feature code 9551) |
2858 -E25 (with feature code 9551) |
2858 -E16 (with feature code 9551) |
2858 -E26 (with feature code 9551) |
2858 -C22 (with feature code 9551) |
2858 -E12 (with feature code 9551) |
2858 -E22 (with feature code 9551) |
| Controller configuration | Single (C) | Dual (active/ active) (CC) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
Dual (active/ active) (CC) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
| Processors speed and type | 2.3 GHz Intel (Quad Core) | 2.3 GHz Intel (Quad Core) | 2.3 GHz Intel (Quad Core) | 2.3 GHz Intel (Quad Core) | 2.3 GHz Intel (Quad Core) | 2.3 GHz Intel (Quad Core) | 3.00 GHz Intel (Dual Core) | 3.00 GHz Intel (Dual Core) | 3.00 GHz Intel (Dual Core) |
| Number of processors (cores) | 1 | 2 | 1 | 2 | 2 | 4 | 4 | 2 | 4 |
| Random access memory | 12 GB | 24 GB | 12 GB | 24 GB | 20 GB | 40 GB | 40 GB | 20 GB | 40 GB |
| Nonvolatile memory | 1.6 GB | 3.2 GB | 1.6 GB | 3.2 GB | 2 GB* | 4 GB* | 4 GB | 2 GB | 4 GB |
| Integrated I/O ports | |||||||||
| Fibre Channel ports (speed) | 2 (4 Gbps) | 4 (4 Gbps) | 2 (4 Gbps) | 4 (4 Gbps) | 2 (4 Gbps) | 4 (4 Gbps) | 4 (4 Gbps) | 2 (4 Gbps) | 4 (4 Gbps) |
| Ethernet ports (speed) | 2 (1 Gbps) | 4 (1 Gbps) | 2 (1 Gbps) | 4 (1 Gbps) | 2 (1 Gbps) | 4 (1 Gbps) | 4 (1 Gbps) | 2 (1 Gbps) | 4 (1 Gbps) |
| SAS ports (speed) | 2 (6 Gbps) | 4 (6 Gbps) | 2 (6 Gbps) | 4 (6 Gbps) | 2 (6 Gbps) | 4 (6 Gbps) | 4 (6 Gbps) | 2 (6 Gbps) | 4 (6 Gbps) |
| Storage scalability | |||||||||
| Maximum number of Fibre Channel loops | 5 | 5 | 13 | 13 | 13 | 13 | 5 | 13 | 13 |
| Maximum raw capacity | 1,920 TB | 1,920 TB | 1,920 TB | 1,920 TB | 2,880 TB | 2,880 TB | 3,840 TB | 3,840 TB | 3,840 TB |
| Maximum number of disk drives | 480 | 480 | 480 | 480 | 720 | 720 | 960 | 960 | 960 |
| Maximum volume size | 16 TB (32-bit) 60 TB (64-bit) |
16 TB (32-bit) 60 TB (64-bit) |
16 TB (32-bit) 60 TB (64-bit) |
16 TB (32-bit) 60 TB (64-bit) |
16 TB (32-bit) 70 TB (64-bit) |
16 TB (32-bit) 70 TB (64-bit) |
16 TB (32-bit) 70 TB (64-bit) |
16 TB (32-bit) 70 TB (64-bit) |
16 TB (32-bit) 70 TB (64-bit) |
| Maximum number of volumes/LUNs | 4,096 | 4,096 | 4,096 | 4,096 | 4,096 | 4,096 | 4,096 | 4,096 | 4,096 |
| Maximum number of Fibre Channel or iSCSI SAN connected servers | Up to 512 hosts per high-availability (HA) pair Up to 24 directly connected servers per HA pair |
||||||||
| Disk expansion units supported | EXN1000 - SATA Disk Storage Expansion | ||||||||
| EXN3000 - SAS/SATA Disk Storage Expansion | |||||||||
| EXN3200 - SATA Disk Storage Expansion (HDD) | |||||||||
| EXN3500 - SAS Disk Storage Expansion (SFF) | |||||||||
| EXN4000 - 4 Gbps Fibre Channel Disk Storage Expansion Unit | |||||||||
| I/O scalability | |||||||||
| PCIe expansion slots | 2 | 4 | 6 | 12 | 6 | 12 | 4 | 6 | 12 |
| Maximum number Fibre Channel ports | 10 | 20 | 26 | 52 | 26 | 52 | 20 | 26 | 52 |
| Maximum number of Ethernet ports | 10 | 20 | 26 | 52 | 26 | 52 | 20 | 26 | 52 |
| Maximum number of SAS ports | 10 | 20 | 26 | 52 | 26 | 52 | 20 | 26 | 52 |
| Maximum number of optional adapters | 2 | 4 | 6 | 12 | 6 | 12 | 4 | 6 | 12 |
| N6220 | N6220 | N6220 | N6220 | N6250 | N6250 | N6270 | N6270 | N6270 | |
|---|---|---|---|---|---|---|---|---|---|
| Machine type model | 2858 -C15 |
2658 -C25 |
2858 -E15 |
2858 -E25 |
2858 -E16 |
2858 -E26 |
2858 -C22 |
2858 -E12 |
2858 -E22 |
| Gateway machine type model | 2858 -C15 (with feature code 9551) |
2658 -C25 (with feature code 9551) |
2858 -E15 (with feature code 9551) |
2858 -E25 (with feature code 9551) |
2858 -E16 (with feature code 9551) |
2858 -E26 (with feature code 9551) |
2858 -C22 (with feature code 9551) |
2858 -E12 (with feature code 9551) |
2858 -E22 (with feature code 9551) |
| Controller configuration | Single (C) | Dual (active/ active) (CC) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
Dual (active/ active) (CC) |
Single + IO Exp (CI) | Dual (active/ active) (CI-HA) |
| AC power/ current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 − 240 V only) |
100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) | 100 − 240 V ac, 12 − 8 A (max) |
| 3.09 A @ 100 − 120 V ac (typical) | 4.70 A @ 100 − 120 V ac (typical) | 3.71 A @ 100 − 120 V ac (typical) | 7.42 A @ 100 − 120 V ac (typical) | 4.14 A @ 100 − 120 V ac (typical) | 8.28 A @ 100 – 120 V ac | 5.56 A @ 100 − 120 V ac (typical) | 4.14 A @ 100 − 120 V ac (typical) | 8.28 A @ 100 − 120 V ac (typical) | |
| 1.73 A @ 200 − 240 V ac (typical) | 2.41 A @ 200 − 240 V ac (typical) | 1.96 A @ 200 − 240 V ac (typical) | 3.92 A @ 200 − 240 V ac (typical) | 2.13 A @ 200 − 240 V ac (typical) | 4.26 A @ 200 – 240 V ac (typical) | 2.81 A @ 200 − 240 V ac (typical) | 2.13 A @ 200 − 240 V ac (typical) | 4.26 A @ 200 − 240 V ac (typical) | |
| Thermal rating | 1,437 BTU/hr (maxi mum) |
2,168 BTU/hr (maxi mum) |
1,707 BTU/hr (maxi mum) |
3,414 BTU/hr (maxi mum) |
1,867 BTU/hr (maxi mum) |
3,734 BTU/hr (maxi mum) |
2,485 BTU/hr (maxi mum) |
1,867 BTU/hr (maxi mum) |
3,734 BTU/hr (maxi mum) |
| Weight (maximum) | 30.9 kg (68 lb) | 36.4 kg (80 lb) | 33.6 kg (74 lb) | 67.2 kg (148 lb) | 33.6 kg (74 lb) | 67.2 kg (148 lb) | 36.4 kg (80 lb) | 33.6 kg (74 lb) | 67.2 kg (148 lb) |
| Height | 13 cm (5.12 in.), fits into 3U space | 13 cm (5.12 in.), fits into 3U space | 13 cm (5.12 in.), fits into 3U space | 26 cm (10.24 in.), fits into 6U space | 13 cm (5.12 in.), fits into 3U space | 26 cm (10.24 in.), fits into 6U space | 13 cm (5.12 in.), fits into 3U space | 13 cm (5.12 in.), fits into 3U space | 26 cm (10.24 in.), fits into 6U space |
| Width | 19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
19 in. IEC rack- comp liant (44.7 cm, 17.6 in.) |
| Depth | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) | 61 cm (24 in.), 64.5 cm (25.4 in.) |
| Operating temperature, altitude, and relative humidity (maximum) | 10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
10°C − 40°C (50°F − 104°F); at /= 3,050 m (at /= 10,000 ft) eleva tion; 20% − 80% relative humi dity, noncon densing (28°C wet bulb tempe rature) |
| Non-operating temperature and relative humidity | -40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
-40°C −70°C (-40°F −158° F); 10% −95% rela tive humi dity, non conden sing, in original con tainer |
| Operating acoustic noise | 55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
55.5 dBA sound press ure (LpA) @ normal opera ting condi tions (at 23°C and at sea level) |
| Minimum cabinet clearances | 25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
25.4 cm ( 10 in.) front; 30.5 cm ( 12 in.) rea |
| Minimum service clearances | 76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
76.2 cm (30.5 in.) from front of cabinet; 76.2 cm (30 in.) from rear of cabine |
| Maximum altitude | 3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
3,050 m ( 10,000 ft) |
| Regulations | |
|---|---|
| Filer safety | EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition) CB (all national deviations), EN60825-1:2007, IRAM, GOST-R |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI |
| Immunity | EN 55024:1998 +A1:2001 +A2:2003 |
| Storage expansion unit disk drive support | |
| EXN4000 – 4 Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | Fibre Channel: 300 GB, 450 GB, 600 GB (15k rpm) |
| EXN3500 – SAS Disk Storage Expansion Unit small-form factor (SFF) (MTM 2857-006) | SAS SFF: 450 GB, 600 GB, 900 GB (10k rpm): 200 GB SSD |
| EXN3200 – SATA Disk Storage Expansion Unit HDD (MTM 2857-306) | SATA: 3 TB, 4 TB (7.2k rpm) |
| EXN3000 – SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB, 600 GB SED (15k rpm) SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm); 100 GB SSD |
| EXN1000 – SATA disk storage expansion unit (MTM 2861-001) | SATA: 1 TB, 2 TB (7.2k rpm) |
| Storage expansion unit specifications | |
| Disk storage expansion units supported | EXN4000: 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) with 14 low-profile slots for Fibre Channel disk drives EXN3500: SAS SFF Disk Storage Expansion Unit (MTM 2857-006) with 24 SFF slots for SAS SFF disk drives EXN3200: SATA Disk Storage Expansion Unit (MTM 2857-306) with 24 dual hard disk drive (HDD) slots for 3.5-inch HDD product platforms EXN3000: SAS Disk Storage Expansion Unit (MTM 2857-003) with 24 slots for SAS or SATA disk drives EXN1000: SATA Disk Storage Expansion Unit (MTM 2861-001) with 14 low-profile slots for SATA disk drives Legacy support for expansion units |
| Storage expansion unit interfaces | Onboard or PCIe Fibre Channel-Arbitrated Loop (FC-AL) Onboard or PCIe SAS 3 Gbps or 6 Gbps |
| Environmental specifications | |
| Power supply/cooling fans | EXN3000: Dual (SATA) or Quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V) EXN1000, EXN3500, EXN4000: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V) EXN3200: Quad, redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V) |
| AC power/maximum current | 100 − 120 V ac/4.4 A; 200 − 240 V ac/2.3 A; 100 − 120 V ac/7 A; 200 V ac - 240 V ac/3.5 A; 50/60 Hz |
| Operating temperature maximum range | 10°C − 40°C (50°F − 104°F) |
| Recommended operating temperature range | 20°C − 25°C (68°F − 77°F) |
| Operating relative humidity range | 20% − 80% relative humidity, noncondensing 10% − 95% |
| Recommended operating relative humidity range | 40% − 55% noncondensing |
| Nonoperating temperature range | -40°C − 70°C (-40°F − 158°F) |
| Nonoperating relative humidity range | 10% − 95% relative humidity, noncondensing |
| Thermal rating | 1,437 − 3,734 BTU/hr |
| Operating acoustic noise | 55.5 dBA @ 1 m at 23°C |
| Dimensions (height/width/depth) | EXN4000 and EXN1000
|
| Weight | EXN4000: 35.8 kg (78.8 lb) fully loaded with disk drives, 23 kg (50.6 lb) empty (without PCMs and PSUs) EXN3500: 22.2 kg (49 lb) fully loaded with disk drives, 15.7 kg (34.6 lb) empty EXN3200: 68.04 kg (150 lb) fully loaded with disk drives, 17.69 kg (39 lb) empty EXN3000: 49.9 kg (110 lb) fully loaded with disk drives, 24.4 kg (53.7 lb) empty EXN1000: 77 lb (35 kg) fully loaded with disk drives, 50.6 lb (23 kg) empty |
| Regulations | |
|---|---|
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |
Contact IBM

- Request a quote
- Email IBM
Call IBM: 1-866-883-8901
Priority code: 101J413W
Related links
N6000 tours in 3D
Take the 3D tour for these products