| N3150 | N3150 | N3220 | N3220 | N3240 | N3240 | |
|---|---|---|---|---|---|---|
| Machine type model | 2857-A15 | 2857-A25 | 2857-A12 | 2857-A22 | 2857-A14 | 2857-A24 |
| Controller configuration | Single | Dual (active/active) | Single | Dual (active/active) | Single | Dual (active/active) |
| Processor speed and type | Dual-core Intel Xeon 1.73 GHz | |||||
| Random access memory | 6 GB | 12 GB | 6 GB | 12 GB | 6 GB | 12 GB |
| Fibre Channel ports (speed) | N/A | N/A | 2 (8 Gbps)1 | 4 (8 Gbps)1 | 2 (8 Gbps)1 | 4 (8 Gbps)1 |
| Ethernet ports (speed) | 4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
| Maximum raw capacity | 240 TB | 501 TB | 576 TB | |||
| Maximum number of disk drives | 60 12 internal |
144 24 internal |
144 24 internal |
|||
| Disk drives supported in controller (type, size, speed) | SAS: 450 GB, 600 GB, 600 GB SED, 900 GB (10k rpm), 4 TB nearline (7.2k rpm) SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm) SSD: 100 GB, 200 GB, 800 GB Hybrid configuration: 200 GB SSD with 2 TB SATA or 900 GB SAS |
SAS: 450 GB, 600 GB, 900 GB (10k rpm) SSD: 200 GB, 800 GB Hybrid configuration: 200 GB SSD with 900 GB SAS |
SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm), 4 TB nearline (7.2k rpm) SSD: 200 GB Hybrid configuration: 200 GB SSD with 2 TB SATA |
|||
| Disk expansion units supported | EXN3000—SAS Disk Storage expansion unit: SAS—300 GB, 450 GB, 600 GB, 600 GB SED (15k rpm), 4 TB nearline (7.2k rpm) SATA—1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm) Hybrid configuration: 200 GB SSD with 2 TB SATA EXN3500—SAS Disk Storage small form-factor expansion unit: SAS—450 GB, 600 GB, 600 GB SED, 900 GB (10k rpm); SSD—200 GB, 800 GB Hybrid configuration: 200 GB SSD with 900 GB SAS |
|||||
| Warranty | 3 years for hardware and licensed software, customer-replaceable unit (CRU) and on-site service, next business day 9×5, service upgrades available | |||||
| N3150 | N3150 | N3220 | N3220 | N3240 | N3240 | |
|---|---|---|---|---|---|---|
| Machine type model | 2857-A15 | 2857-A25 | 2857-A12 | 2857-A22 | 2857-A14 | 2857-A24 |
| Controller configuration | Single | Dual (active/active) | Single | Dual (active/active) | Single | Dual (active/active) |
| Processor speed and type | Dual-core Intel Xeon 1.73 GHz | |||||
| Number of processors | 1 | 2 | 1 | 2 | 1 | 2 |
| Random access memory | 6 GB | 12 GB | 6 GB | 12 GB | 6 GB | 12 GB |
| Fibre Channel ports (speed) | N/A | N/A | 2 (8 Gbps)1 | 4 (8 Gbps)1 | 2 (8 Gbps)1 | 4 (8 Gbps)1 |
|---|---|---|---|---|---|---|
| Ethernet ports (speed) | 4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
4 (1 Gbps) onboard 2 (10 Gbps)1 |
8 (1 Gbps) onboard 4 (10 Gbps)1 |
| Maximum number of Fibre Channel loops | N/A | |||||
|---|---|---|---|---|---|---|
| Maximum raw capacity | 240 TB | 501 TB | 576 TB | |||
| Maximum number of internal drives | 12 | 24 | 24 | |||
| Maximum number of expansion drives | 48 | 120 | 120 | |||
| Maximum number of disk drives | 60 | 144 | 144 | |||
| Maximum volume size | 53.7 TB (64-bits) | 53.7 TB (64-bits) | 53.7 TB (64-bits) | |||
| Maximum number of storage enclosures | 2 SAS | 5 SAS | 5 SAS | |||
| Disk drives supported in controller (type, size, speed) | SAS: 450 GB, 600 GB, 600 GB SED, 900 GB (10k rpm), 4 TB nearline (7.2k rpm) SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm) SSD: 100 GB, 200 GB, 800 GB Hybrid configuration: 200 GB SSD with 2 TB SATA or 900 GB SAS |
SAS: 450 GB, 600 GB, 900 GB (10k rpm) SSD: 200 GB, 800 GB Hybrid configuration: 200 GB SSD with 900 GB SAS |
SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm), 4 TB nearline (7.2k rpm) SSD: 200 GB Hybrid configuration: 200 GB SSD with 2 TB SATA |
|||
| Disk expansion units supported | EXN3000—SAS Disk Storage expansion unit: SAS—300 GB, 450 GB, 600 GB, 600 GB SED (15k rpm), 4 TB nearline (7.2k rpm) SATA—1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm) Hybrid configuration: 200 GB SSD with 2 TB SATA EXN3500—SAS Disk Storage small form-factor expansion unit: SAS—450 GB, 600 GB, 600 GB SED, 900 GB (10k rpm); SSD—200 GB, 800 GB Hybrid configuration: 200 GB SSD with 900 GB SAS |
|||||
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 – 240 V only) | R6 100 – 240 V ac 16A – 6A (8A - 3A per inlet) 60/50 Hz 0.7 kVA R6 100 –120 V ac/200 – 240 V ac 16A – 6A 60/50 Hz 0.7 kVA |
R6 100 – 240 V ac 16A – 6A (8A – 3A per inlet) 60/50 Hz 0.7 kVA R6 100 – 120 V ac/200 – 240 V ac 16A – 6A 60/50 Hz 0.7 kVA |
R6 100 – 240 V ac 16A – 6A (8A – 3A per inlet) 60/50 Hz 0.7 kVA R6 100 – 120 V ac / 200 – 240 V ac 16A – 6A 60/50 Hz 0.7 kVA |
|||
|---|---|---|---|---|---|---|
| Thermal rating | 1,461 BTU/hr. (note: watts x 3.4129) | 1,461 BTU/hr. (note: watts x 3.4129) | 2,201 BTU/hr. (note: watts x 3.4129) | |||
| Weight (maximum) | 28.3 kg (62.4 lb) | 22.2 kg (49.0 lb) | 46 kg (102 lb) | 28 kg (64 lb) | ||
| Height | 8.5 cm (3.34 in.), fits into 2U space | 8.5 cm (3.34 in.), fits into 2U space | 17.5 cm (6.88 in.), fits into 4U space | |||
| Width | 19 in. IEC rack-compliant (44.7 cm, 17.61 in.) | 19 in. IEC rack-compliant (44.7 cm, 17.61 in.) | 19 in. IEC rack-compliant (48.3 cm, 19.02 in.) | |||
| Depth | 61.2 cm (24.1 in.) | 54.3 cm (21.4 in.) | 60.3 cm (23.75 in.) | |||
| Operating temperature, altitude and relative humidity | 10°C – 40°C (50°F – 104°F); ≤ 3,000 m (≤10,000 ft) elevation; 20% – 80% relative humidity, noncondensing (28°C wet bulb temperature) | |||||
| Non-operating temperature and relative humidity | -40°C – 60°C (-40°F – 140°F); 10% – 95% relative humidity, noncondensing, in original container | |||||
| Operating acoustic noise | 7.2 bels at normal operating conditions (at 23°C and at sea level) | |||||
| Minimum cabinet clearances | 25.4 cm (10 in.) in front, 30.5 cm (12 in.) in rear | |||||
| Minimum service clearances | 76.2 cm (30 in.) in front, 76.2 cm (30 in.) in rear | |||||
| Maximum altitude | 3,050 m (10,000 ft) | |||||
| Filer safety | EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R, BSMI CNS14336, CCC GB 4943-2001, SABS, S Resolution 92 – 98 | |||||
|---|---|---|---|---|---|---|
| Disk shelf safety | UL/C-UL; CE | |||||
| Emissions/immunity | FCC Part 15 Class A, ICES-003, CE, MIC, VCCI, AS/NZS EN55022, EN55024, IEC61000-3-2, IEC61000-3-3, BSMI, KN22, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, KN24, CISPR 24 | |||||
| Warranty | 3 years for hardware and licensed software, customer-replaceable unit (CRU) and on-site service, next business day 9×5, service upgrades available | |||||
| EXN3000—SAS Disk Storage expansion unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB, 600 GB SED (15k rpm), 4 TB nearline (7.2 rpm) SATA: 1 TB, 2 TB, 3 TB, 3 TB SED (7.2k rpm) Hybrid configuration: 200 GB SSD with 2 TB SATA |
|---|---|
| EXN3500—SAS Disk Storage SFF expansion unit (MTM 2857-006)1 | SAS SFF: 450 GB, 600 GB, 600 GB SED, 900 GB (10k rpm) SSD: 200 GB, 800 GB Hybrid configuration: 200 GB SSD with 900 GB SAS |
| Storage expansion unit interfaces | Onboard or PCIe Fibre Channel Arbitrated Loop Onboard or PCIe SAS 3 Gbps or 6 Gbps |
|---|
| Power supply/cooling fans | EXN3000: Dual (SATA) or quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V) EXN3500: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220/110 V) |
|---|---|
| AC power/maximum current | 100 – 120 V ac/4.4A; 200 – 240 V ac/2.3A; 100 – 120 V ac/7A; 200 – 240 V ac/3.5A; 50/60 Hz |
| Operating temperature maximum range | 10°C – 40°C (50°F – 104°F) |
| Recommended operating temperature range | 20°C – 25°C (68°F – 77°F) |
| Operating relative humidity range | 10% – 95% relative humidity, noncondensing 10% – 95% |
| Recommended operating relative humidity range | 40% – 55% noncondensing |
| Non-operating temperature range | -40°C – 65°C (-40°F – 149°F) |
| Non-operating relative humidity range | 10% – 95% relative humidity, noncondensing |
| Thermal rating | 1,437 – 3,414 BTU/hr. |
| Operating acoustic noise | 56.4 dBA at 1 m at 23°C, 5.64 bels at 23°C |
| Dimensions (height/width/depth) | EXN3000
|
| Weight | EXN3000
|
| Disk shelf safety | UL/C-UL; CE |
|---|---|
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |
| SAN protocol support | Fibre Channel Protocol (FCP), or iSCSI |
|---|---|
| Network protocol support | NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, HTTP 1.0, HTTP 1.1 virtual hosts, FTP |
| FlexVol | Up to 500 per controller |
| Snapshots | Up to 127,000 per controller |
| Reliability | Redundant hot-swappable controllers, cooling fans and power supplies |
| Management | Full-duplex 10/100 Base-T Ethernet onboard console, diagnostic LED, Maintenance Center, SNMP, telnet, SSH, HTTP, web, email alerts |
| Security | Virus protection, SecureAdmin, IPsec, CHAP authentication, role-based access control (RBAC) |