Our world-class EMC Labs are accredited by NVLAP in the USA, VCCI in Japan, and BSMI in Taiwan. We offer facilities that include 3- and 10-meter semi-anechoic chambers and experienced personnel capable of providing complete radiated and conducted electromagnetic field emissions and immunity measurements to meet the following regulations:
- FCC (US)
- VCCI (Japan)
- EMC Directive (Europe)
- BSMI (Taiwan)
- ICES/NMB (Canada)
- AS/NZS 3548 (Australia and New Zealand)
- MIC/RRL (Korea)
Our EMC services include verification for Class A commercial products and certification for Class B consumer products. All required documentation (test results and test reports) are provided.
Test capabilities
Radiated and Conducted RF Emissions
FCC Title 47 CFR Part 15 Subpart B,
CISPR22, EN 55022, KN 22, VCCI, CNS
13438, AS/NZ 3548
Power Harmonic Emissions
Voltage Fluctuations and Flicker Emissions
Immunity
Electrostatic Discharge (ESD) Immunity
Radiated RF Immunity
EN 61000-3-2, EN 61000-3-12
IEC 61000-3-3, IEC 61000-3-11
EN 55024, KN 24
IEC 61000-4-2, KN 61000-4-2
EN 61000-4-3, KN 61000-4-3
Electrical Fast Transient / Burst (EFT/B) Immunity
IEC 61000-4-4, KN 61000-4-4
Surge Immunity
Conducted RG Immunity
Power Frequency Magnetic Fields Immunity
Voltage Dips and Short Interruptions Immunity
EN 61000-4-5, KN 61000-4-5
EN 61000-4-6, KN 61000-4-6
EN 61000-4-8, KN 61000-4-8
EN 61000-4-11, KN 61000-4-11
Test facilities
10-meter semi-anechoic chamber
Two 3-meter semi-anechoic chamber
Three Shield rooms
Laboratory accreditations
NVLAP
VCCI
BSMI
Contact IBM
Phone: (919) 254-2408
FAX: (919) 254-7778