- Overview
- Features & benefits
- Specifications- selected tab,
| Processor core types: CP/IFL/ICF/zAAP1/zIIP1 | |||
|---|---|---|---|
| Model | Minimum | Maximum | Increments |
| E12 | 1/1/1/0/0 | 12/12/12/6/6 | 1/1/1/1/1 |
| E26 | 1/1/1/0/0 | 26/26/16/13/13 | 1/1/1/1/1 |
| E40 | 1/1/1/0/0 | 40/40/16/20/20 | 1/1/1/1/1 |
| E56 | 1/1/1/0/0 | 56/56/16/28/28 | 1/1/1/1/1 |
| E64 | 1/1/1/0/0 | 64/64/16/32/32 | 1/1/1/1/1 |
| Coupling Links | |||
|---|---|---|---|
| ISC-32 | 48 | ||
| IC | 32 | ||
| ICB-43 | 16 | ||
| Maximum # Links | 644 | ||
| InfiniBand Coupling Links | 32 | ||
| Channels | |||
|---|---|---|---|
| Minimum: 0/0/0/0/0/0/0 | ESCON/FICON Express8/FICON Express4/FICON Express25/FICON Express5/OSA-Express3/OSA-Express2 | ||
| Maximum: 1024/336/336/336/120/96:48/48 | ESCON/FICON Express8/FICON Express4/FICON Express25/FICON Express5/OSA-Express3/OSA-Express2 | ||
| Increments: 4/4/4/4/2/4/2/2/1 | ESCON/FICON Express8/FICON Express4/FICON Express25/FICON Express5/OSA-Express3 GbE, 1000BASE-T/OSA-Express3 10 GbE/OSA-Express2 GbE, 1000BASE-T/OSA-Express2 10 GbE | ||
| HiperSockets | Up to sixteen high-speed ‘virtual’ LANs (VLANs) | ||
| Cryptographic6 | |||
|---|---|---|---|
| Crypto Express3 and Crypto Express2 | Optional up to eight features (16 PCI-X adapters), minimum order is two features | ||
| Processor Memory | |||
|---|---|---|---|
| Model | Minimum | Maximum7 | |
| E12 | 16 GB | 3848 GB | |
| E26 | 16 GB | 752 GB | |
| E40 | 16 GB | 1136 GB | |
| E56 | 16 GB | 1520 GB | |
| E64 | 16 GB | 1520 GB | |
| Upgradeability | Upgradeable within the z10 EC family Upgrading to the E64 from other z10 EC models will require a planned outage Upgradeable from IBM System z9 EC and IBM eServer zSeries 990 (z990) |
||
| Physical Configuration | Model E12, minimum9 | Model E64, maximum10 | |
| Weight | 1248 kg (2807 lbs) | 2271 kg (5110 lbs) | |
| Footprint | 2.83 Sq metres (30.44 Sq ft) | 2.83 Sq metres (30.44 Sq ft) | |
| Service | 5.73 Sq metres (61.60 Sq ft) | 5.73 Sq metres (61.60 Sq ft) | |
| Input | 9.7 kW | 27.5 kW | |
| Heat | 33.1 KBTU/hr | 93.8 KBTU/hr | |
| Air Flow Nominal11 | CFM 1155 m3/m | CFM 2465, m3/m | |
| Height | 201.32 cm (79.26 inches) | 201.32 cm (79.26 inches) | |
| General | Conforms to EIA guidelines for frames | ||
| Supported Operating Systems | |||
|---|---|---|---|
| z/OS: | z/OS V1.9 and subsequent releases | ||
| z/VM: | z/VM 5.3 and subsequent releases | ||
| Linux on System z: | Red Hat Enterprise Linux (RHEL) 4 and subsequent releases, Novell SUSE Linux Enterprise Server (SLES) 9 and subsequent releases, Linux as z/VM guest | ||
| z/VSE: | z/VSE V4.1 and subsequent releases | ||
| TPF: | TPF 4.1 | ||
| z/TPF: | z/TPF 1.1 | ||
1 If ordering a zAAP or a zIIP, one or more general purpose processor (CP) per the specialty engine is required. One CP can satisfy the requirement for either or both of the specialty engines.
2 ISC-3 Peer mode only
3 ICB-4 Not available on E64
4 64 external and 32 internal
5 Available only when carried forward on an upgrade
6 Initial order of Crypto Express3 requires 2 features, maximum of 8 features
7 Excludes the standard fixed size of 16 GB HSA
8 Full installed capacity can not be used until second book is installed due to 32 GB increments for memory between 256-512 GB
9 Model E12 with one I/O cage and no Internal Battery Feature (IBF)
10 Model E26 with three I/O cages and IBF with a combined max of 64
11 Airflow is designed to increase as the local ambient room temperature increases. Nominal airflow assumes 77 degrees F ambient.