- Overview
- Features and benefits
- Specifications- selected tab,
| N7950T | |
|---|---|
| Machine type model | 2867-E22 |
| Gateway machine type model | 2867-E22 (with Fibre Channel 9551) |
| Controller configuration | Dual (active/active) |
| Processors speed and type | 2.93 GHz Intel 6-core |
| Number of processors | 24 |
| Random access memory | 192 GB1 |
| Nonvolatile memory | 8 GB |
| Integrated I/O ports | |
| Fibre Channel ports/speed | 8 (4 Gbps) |
| SAS ports/speed | 8 (6 Gbps) |
| Ethernet ports/speed | 8 (10 Gbps), 4 (1 Gbps) |
| Storage scalability | |
| Maximum number of Fibre Channel loops | 14 |
| Maximum number of SAS stacks | 10 |
| Maximum raw capacity | 4320 TB |
| Maximum number of disk drives | 1440 |
| Maximum volume size | 100 TB |
| Maximum size of volumes/LUNs | 4096 |
| Maximum number of storage enclosures | 84 |
| Disk expansion units supported | EXN4000: Fibre Channel Disk Storage Expansion Unit: 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB (15k RPM) EXN3500: SAS Disk Storage (SFF) Expansion Unit: SAS: 450 GB, 600 GB (10k RPM) EXN3000: SAS Disk Storage Expansion Unit: SAS: 300 GB, 450 GB, 600 GB (15k RPM); SATA: 1 TB, 2 TB, 3 TB (7.2k RPM), 100 GB SSD EXN1000: SATA Disk Storage Expansion Unit: SATA: 1 TB, 2 TB (7.2k RPM) |
| I/O scalability | |
| PCI-Express (PCI-e) expansion slots | 24 |
| PCI-x expansion slots | 0 |
| Maximum number of Fibre Channel ports | 128 |
| Maximum number of Ethernet ports | 100 |
| Maximum number of SAS ports | 72 |
| Maximum number of adapters supported per system (below—not to exceed maximum number of optional adapters) | |
| 1012 - Dual-Port GbE NIC (fibre) | 24 |
| 1014 - Dual-Port 4-Gbps Fibre Channel HBA Disk | 24 |
| 1015 - Dual-Port 4-Gbps Fibre Channel HBA Tape | 16 |
| 1028 - Quad Port GbE (copper) | 12 |
| 1029 - Quad-Port 4-Gbps Fibre Channel HBA - DISK | 24 |
| 1030 - Quad-Port 4-Gbps Fibre Channel Target | 12 |
| 1036 - PCIe 2 port 8 Gb Fibre Channel Target HBA | 24 |
| 1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment3 | 12 |
| 1063 - Dual-port FCoE adapter (optical) | 24 |
| 1064 - Dual-port FCoE adapter (cooper) | 24 |
| 1066 - MetroCluster VI Fibre Channel HBA 8Gb | 2 |
| 1067 - SnapMirror over Fibre Channel HBA 8Gb | 4 |
| 1071 - Flash Cache II 512Gb | 32 |
| 1072 - Flash Cache II 1Tb | 16 |
| 1078 - Dual-Port 10 GbE NIC, SFP+ | 16 |
| 1079 - Quad-Port 8 Gb Fibre Channel HBA | 6 |
| 1080 - Quad-Port 6 Gb SAS HBA | 6 |
| 2013 - SFP+ 10 GbE - Embedded NIC | 8 |
| 2014 - SFP+ Optical Module for 1078 | 32 |
| Warranty | 3 years for hardware and licensed software, CRU and Onsite service, next business day 9×5, service upgrades available |
| 3 | For use with the EXN3000/EXN3500 and QSFP-QSFP cabling |
| 1 | 192 GB of physical memory; actual memory allocated depends on the Data ONTAP release in use |
Environmental specifications for N7000 series
| N7950T | |
|---|---|
| Machine type model | 2867-E22 |
| Gateway machine type model | 2867-E22 (with Fibre Channel 9551) |
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 120 V ac, 6.9 A (typical), 9.6 A (maximum) @ 100 V ac 200 to 240 V ac, 3.5 A (typical), 4.7 A (maximum) @ 200 V ac |
| Thermal rating | 6486 BTU/hr (maximum), 4540 BTU/hr (typical) |
| Weight (maximum) | 260.2 lbs (118 kg) |
| Height | 20.64 in. (52.42 cm), fits into 12U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.6 cm) |
| Depth | 24 in. (61 cm), 29 in. (73.66 cm) with cable management bracket |
| Operating temperature, altitude and relative humidity | 10°C to 40°C (50°F to 104°F); at ≤ 3,050 m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Nonoperating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Minimum cabinet clearances | 6 in. (15.2 cm) front; 12 in. (30.5 cm) rear |
| Minimum. service clearances | 25 in. (63.5 cm) from front of cabinet; 40 in. (102 cm) from rear of cabinet |
| Maximum altitude | 2133 m (7,000 ft) |
Specifications for N6000 series
| N6210 | N6210 | N6240 | N6240 | |
|---|---|---|---|---|
| Machine type model | 2858-C10 (with Fibre Channel 9551) | 2858-C20 (with Fibre Channel 9551) | 2858-C21 (with Fibre Channel 9551) | 2858-E11 (with Fibre Channel 9551) |
| Controller configuration | Single (C) | Dual (active/active) (CC) | Dual (active/active) (CC) | Single + IO Exp (CI) |
| Processors speed and type | 2.3 GHz Intel (dual core) | 2.3 GHz Intel (quad core) | ||
| Number of processors (cores) | 2 | 4 | 8 | 4 |
| Random access memory | 4 GB | 8 GB | 16 GB | 8 GB |
| Nonvolatile memory | 512 MB | 1 GB | 2 GB | 1 GB |
| Integrated I/O ports | ||||
| Fibre Channel ports (speed) | 2 (4-Gbps) | 4 (4-Gbps) | 4 (4-Gbps) | 2 (4-Gbps) |
| Ethernet ports (speed) | 2 (1-Gbps) | 4 (1-Gbps) | 4 (1-Gbps) | 2 (1-Gbps) |
| SAS ports (speed) | 2 (6-Gbps) | 4 (6-Gbps) | 4 (6-Gbps) | 2 (6-Gbps) |
| Storage scalability | ||||
| Maximum number of Fibre Channel loops | 10 | 10 | 8 | 13 |
| Maximum raw capacity | 480 TB | 480 TB | 1200 TB | 1200 TB |
| Maximum number of disk drives | 240 | 240 | 600 | 600 |
| Maximum volume size | 16 TB (32-bit) 50 TB (64-bit) |
16 TB (32-bit) 50 TB (64-bit) |
16 TB (32-bit) 50 TB (64-bit) |
16 TB (32-bit) 50 TB (64-bit) |
| Maximum number of volumes/LUNs | 4096 | 4096 | 4096 | 4096 |
| Maximum number of storage enclosures | 20 | 20 | 42 | 42 |
| Maximum number of Fibre Channel or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | |||
| Disk expansion units supported | EXN1000 - SATA Disk Storage Expansion | |||
| EXN3000 - SAS/SATA Disk Storage Expansion | ||||
| EXN3500 - SAS Disk Storage Expansion (SFF) | ||||
| EXN4000 - 4 Gbps Fibre Channel Disk Storage Expansion Unit | ||||
| I/O scalability | ||||
| PCI-e expansion slots | 2 | 4 | 4 | 6 |
| Maximum number Fibre Channel ports | 10 | 20 | 20 | 26 |
| Maximum number of Ethernet ports | 10 | 20 | 20 | 22 |
| Maximum number of SAS ports | 20 | 20 | 20 | 26 |
| Maximum number of optional adapters | 2 | 4 | 4 | 6 |
| Maximum number of adapters supported per system (below - not to exceed maximum number of optional adapters) | ||||
| 1012 - Dual-Port GbE NIC (fibre) | 4 | 8 | 4 | 4 |
| 1013 - Dual-Port GbE NIC (copper) | 4 | 8 | 4 | 4 |
| 1014 - Dual-Port 4-Gbps Fibre Channel HBA Disk | 4 | 8 | 4 | 4 |
| 1015 - Dual-Port 4-Gbps Fibre Channel HBA Tape | 4 | 8 | 4 | 4 |
| 1017 - Dual-Port 4-Gbps Fibre Channel HBA Target | 4 | 8 | 4 | 4 |
| 1021 - Dual-Port GbE iSCSI Target (fibre) | 4 | 8 | 4 | 4 |
| 1022 - Quad-Port GbE TOE NIC (copper) | 4 | 8 | 4 | 4 |
| 1023 - Quad-Port GbE NIC (copper) | 4 | 8 | 4 | 4 |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape | 4 | 8 | 4 | 4 |
| 1026 - Dual-Port GbE NIC (copper) | 4 | 8 | 4 | 4 |
| 1029 - Quad-Port 4-Gbps Fibre Channel HBA - DISK | 4 | 8 | 4 | 4 |
| 1031 - Dual-Port 10-GbE TOE NIC | 4 | 8 | 4 | 4 |
| 1032 - Dual-Port MetroCluster VI HBA | 3 | - | 3 | 3 |
| 1033 - SnapMirror Over Fibre Channel HBA PCI-e | 4 | 8 | 4 | 4 |
| 1035 - Quad-Port 4-Gbps Fibre Channel HBA Tape/Disk | 4 | 8 | 4 | 4 |
| 1056 - Performance Acceleration Module (16 GB) | 4 | 8 | 4 | 4 |
| Environmental specifications | ||||
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) |
| 3.03 A @ 100 - 120 V ac (typical) | 4.64 A @ 100 - 120 V ac (typical) | 4.7 A @ 100 - 120 V ac (typical) | 3.71 A @ 100 - 120 V ac (typical) | |
| 1.6 A @ 200 - 240 V ac (typical) | 2.25 A @ 200 - 240 V ac (typical) | 2.27 A @ 200 - 240 V ac (typical) | 1.87 A @ 200 - 240 V ac (typical) | |
| Thermal rating | 1437 BTU/hr. (maximum) | 2137 BTU/hr. (maximum) | 2168 BTU/hr. (maximum) | 1707 BTU/hr. (maximum) |
| Weight (maximum) | 65.4 lbs (29.7 kg) | 76.2 lbs (34.6 kg) | 76.2 lbs (34.6 kg) | 72.6 lbs (32.9 kg) |
| Height | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) |
| Depth | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel |
| Operating temperature, altitude, and relative humidity (maximum) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Non-operating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Minimum. cabinet clearances | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear |
| Minimum. service clearances | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet |
| Maximum altitude | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) |
| Regulations | ||||
| Filer safety | EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition), CB (all national deviations), EN 60825-1:2007, IRAM, GOST-R | |||
| Disk shelf safety | UL/C-UL; CE | |||
| Emissions | FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI | |||
| Immunity | EN 55024:1998 +A1:2001 +A2:2003 | |||
| Warranty | 3 years for hardware and licensed software, CRU and On-site service, Next Business Day 9x5, service upgrades available | |||
| N6240 | N6270 | N6270 | N6270 | |
|---|---|---|---|---|
| Machine type model | 2858-E21 (with Fibre Channel 9551) | 2858-C22 (with Fibre Channel 9551) | 2858-E12 (with Fibre Channel 9551) | 2858-E22 (with Fibre Channel 9551) |
| Controller configuration | Dual + IO Exp (active/active) (CI-HA) | Dual (active/active) (CC) | Single (CI) | Dual (active/active) (CI-HA) |
| Processors speed and type | 2.3 GHz Intel (quad core) | 3.0 GHz Intel (quad core) | ||
| Number of processors (cores) | 8 | 8 | 4 | 8 |
| Random access memory | 16 GB | 32 GB | 16 GB | 32 GB |
| Nonvolatile memory | 2 GB | 4 GB | 2 GB | 4 GB |
| Integrated I/O ports | ||||
| Fibre Channel ports (speed) | 4 (4-Gbps) | 4 (4-Gbps) | 2 (4-Gbps) | 4 (4-Gbps) |
| Ethernet ports (speed) | 4 (1-Gbps) | 4 (1-Gbps) | 2 (1-Gbps) | 4 (1-Gbps) |
| SAS ports (speed) | 4 (6-Gbps) | 4 (6-Gbps) | 2 (6-Gbps) | 4 (6-Gbps) |
| Storage scalability | ||||
| Maximum number of Fibre Channel loops | 26 | 8 | 13 | 26 |
| Maximum raw capacity | 1200 TB | 1920 TB | 1920 TB | 1920 TB |
| Maximum number of disk drives | 600 | 960 | 960 | 960 |
| Maximum volume size | 16 TB (32-bit) 50 TB (64-bit) | 16 TB (32-bit) 70 TB (64-bit) | 16 TB (32-bit) 70 TB (64-bit) | 16 TB (32-bit) 70 TB (64-bit) |
| Maximum number of volumes/LUNs | 4096 | 4096 | 4096 | 4096 |
| Maximum number of storage enclosures | 42 | 48 | 68 | 68 |
| Maximum number of Fibre Channel or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | 256 | ||
| Disk expansion units supported | EXN1000 - SATA Disk Storage Expansion | |||
| EXN3000 - SAS/SATA Disk Storage Expansion | ||||
| EXN3500 - SAS Disk Storage Expansion (SFF) | ||||
| EXN4000 - 4 Gbps Fibre Channel Disk Storage Expansion Unit | ||||
| I/O scalability | ||||
| PCI-e expansion slots | 12 | 4 | 6 | 12 |
| Maximum number Fibre Channel ports | 52 | 20 | 26 | 52 |
| Maximum number of Ethernet ports | 44 | 20 | 22 | 44 |
| Maximum number of SAS ports | 52 | 20 | 26 | 52 |
| Maximum number of optional adapters | 12 | 4 | 6 | 12 |
| Maximum number of adapters supported per system (below - not to exceed maximum number of optional adapters) | ||||
| 1012 - Dual-Port GbE NIC (fibre) | 8 | 4 | 4 | 8 |
| 1013 - Dual-Port GbE NIC (copper) | 8 | 4 | 4 | 8 |
| 1014 - Dual-Port 4-Gbps Fibre Channel HBA Disk | 8 | 4 | 4 | 8 |
| 1015 - Dual-Port 4-Gbps Fibre Channel HBA Tape | 8 | 4 | 4 | 8 |
| 1017 - Dual-Port 4-Gbps Fibre Channel HBA Target | 8 | 4 | 4 | 8 |
| 1021 - Dual-Port GbE iSCSI Target (fibre) | 8 | 4 | 4 | 8 |
| 1022 - Quad-Port GbE TOE NIC (copper) | 8 | 4 | 4 | 8 |
| 1023 - Quad-Port GbE NIC (copper) | 8 | 4 | 4 | 8 |
| 1024 - Dual-Port SCSI Ultra320 HBA Tape | 8 | 4 | 4 | 8 |
| 1026 - Dual-Port GbE NIC (copper) | 8 | 4 | 4 | 8 |
| 1029 - Quad-Port 4-Gbps Fibre Channel HBA - DISK | 8 | 4 | 4 | 8 |
| 1031 - Dual-Port 10-GbE TOE NIC | 8 | 4 | 4 | 8 |
| 1032 - Dual-Port MetroCluster VI HBA | - | 3 | 3 | - |
| 1033 - SnapMirror Over Fibre Channel HBA PCI-e | 8 | 4 | 4 | 8 |
| 1035 - Quad-Port 4-Gbps Fibre Channel HBA Tape/Disk | 8 | 4 | 4 | 8 |
| 1056 - Performance Acceleration Module (16 GB) | 8 | 4 | 4 | 8 |
| Environmental specifications | ||||
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) |
| 7.42 A @ 100 - 120 V ac (typical) | 5.56 A @ 100 - 120 V ac (typical) | 4.14 A @ 100 - 120 V ac (typical) | 8.28 A @ 100 - 120 V ac (typical) | |
| 3.74 A @ 200 - 240 V ac (typical) | 2.83 A @ 200 - 240 V ac (typical) | 2.13 A @ 200 - 240 V ac (typical) | 4.26 A @ 200 - 240 V ac (typical) | |
| Thermal rating | 3414 BTU/hr. (maximum) | 2485 BTU/hr. (maximum) | 1867 BTU/hr. (maximum) | 3734 BTU/hr. (maximum) |
| Weight (maximum) | 145.2 lbs (65.9 kg) | 76.2 lbs (34.6 kg) | 72.6 lbs (32.9 kg) | 145.2 lbs (65.9 kg) |
| Height | 10.24 in. (26 cm), fits into 6U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) |
| Depth | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel |
| Operating temperature, altitude, and relative humidity (maximum) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Non-operating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Minimum cabinet clearances | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear |
| Minimum service clearances | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet |
| Maximum altitude | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) |
| Regulations | ||||
| Filer safety | EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition), CB (all national deviations), EN 60825-1:2007, IRAM, GOST-R | |||
| Disk shelf safety | UL/C-UL; CE | |||
| Emissions | FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI | |||
| Immunity | EN 55024:1998 +A1:2001 +A2:2003 | |||
| Warranty | 3 years for hardware and licensed software, CRU and On-site service, Next Business Day 9x5, service upgrades available | |||
Environmental specifications and regulations for N6000 series
| N6210 | N6210 | N6240 | N6240 | |
|---|---|---|---|---|
| Machine type model | 2858-C10 (with Fibre Channel 9551) | 2858-C20 (with Fibre Channel 9551) | 2858-C21 (with Fibre Channel 9551) | 2858-E11 (with Fibre Channel 9551) |
| Controller configuration | Single (C) | Dual (active/active) (CC) | Dual (active/active) (CC) | Single + IO Exp (CI) |
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) |
| 3.03 A @ 100 - 120 V ac (typical) | 4.64 A @ 100 - 120 V ac (typical) | 4.7 A @ 100 - 120 V ac (typical) | 3.71 A @ 100 - 120 V ac (typical) | |
| 1.6 A @ 200 - 240 V ac (typical) | 2.25 A @ 200 - 240 V ac (typical) | 2.27 A @ 200 - 240 V ac (typical) | 1.87 A @ 200 - 240 V ac (typical) | |
| Thermal rating | 1437 BTU/hr. (maximum) | 2137 BTU/hr. (maximum) | 2168 BTU/hr. (maximum) | 1707 BTU/hr. (maximum) |
| Weight (maximum) | 65.4 lbs (29.7 kg) | 76.2 lbs (34.6 kg) | 76.2 lbs (34.6 kg) | 72.6 lbs (32.9 kg) |
| Height | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) |
| Depth | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel |
| Operating temperature, altitude, and relative humidity (maximum) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Non-operating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Minimum cabinet clearances | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear |
| Minimum service clearances | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet |
| Maximum altitude | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) |
| N6240 | N6270 | N6270 | N6270 | |
|---|---|---|---|---|
| Machine type model | 2858-E21 (with Fibre Channel 9551) | 2858-C22 (with Fibre Channel 9551) | 2858-E12 (with Fibre Channel 9551) | 2858-E22 (with Fibre Channel 9551) |
| Controller configuration | Dual + IO Exp (active/active) (CI-HA) | Dual (active/active) (CC) | Single (CI) | Dual (active/active) (CI-HA) |
| AC power/current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) | 100 to 240 V ac, 12 A to 8 A (maximum) |
| 7.42 A @ 100 - 120 V ac (typical) | 5.56 A @ 100 - 120 V ac (typical) | 4.14 A @ 100 - 120 V ac (typical) | 8.28 A @ 100 - 120 V ac (typical) | |
| 3.74 A @ 200 - 240 V ac (typical) | 2.81 A @ 200 - 240 V ac (typical) | 2.13 A @ 200 - 240 V ac (typical) | 4.26 A @ 200 - 240 V ac (typical) | |
| Thermal rating | 3414 BTU/hr. (maximum) | 2485 BTU/hr. (maximum) | 1867 BTU/hr. (maximum) | 3734 BTU/hr. (maximum) |
| Weight (maximum) | 145.2 lbs (65.9 kg) | 76.2 lbs (54.9 kg) | 72.6 lbs (54.9 kg) | 145.2 lbs (54.9 kg) |
| Height | 10.24 in. (26 cm), fits into 6U space | 5.12 in. (13 cm), fits into 3U space | 5.12 in. (13 cm), fits into 3U space | 10.24 in. (26 cm), fits into 6U space |
| Width | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) | 19 in. IEC rack-compliant (17.6 in., 44.7 cm) |
| Depth | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel | 24 in. (61 cm), 25.4 in. (64.5 cm) with bezel |
| Operating temperature, altitude, and relative humidity (maximum) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | 10°C to 40°C (50°F to 104°F); at ≤ 3,050m (at ≤ 10,000) elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) |
| Non-operating temperature and relative humidity | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container | −40°C to 70°C (−40°F to 158°F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating acoustic noise | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) | 55.5 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Minimum. cabinet clearances | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear | 10 in. (25.4 cm) front; 12 in. (30.5 cm) rear |
| Minimum. service clearances | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet | 30.5 in. (76.2 cm) from front of cabinet; 30 in. (76.2 cm) from rear of cabinet |
| Maximum altitude | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) | 3050 m (10,000 ft) |
| Regulations | |
|---|---|
| Filer safety | EN 60950-1:2006/A11:2009, CE, NRTL (CSA 60950-1-07, UL 60950-1 Second Edition) CB (all national deviations), EN60825-1:2007, IRAM, GOST-R |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:2006 +A1:2007, EN 61000-3-2:2006, EN 61000-3-3:1995 +A1:2001 +A2:2005, CE, BSMI, AS/NZ CISPR 22:2006, VCCI |
| Immunity | EN 55024:1998 +A1:2001 +A2:2003 |
| Storage expansion unit disk drive support | |
|---|---|
| EXN4000: 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | Fibre Channel: 300 GB, 450 GB, 600 GB (15k RPM) |
| EXN3500: SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) | SAS SFF: 450 GB, 600 GB (10k RPM) |
| EXN3000:SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB (15k RPM) SATA: 1 TB, 2 TB, 3 TB (7.2k RPM); 100 GB SSD |
| EXN1000: SATA Disk Storage Expansion Unit (MTM 2861-001) | SATA: 1 TB, 2 TB (7.2k RPM) |
| Storage expansion unit specifications | |
| Disk storage expansion units supported | EXN4000: 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) with 14 low-profile slots for fibre channel disk drives EXN3500: SAS Small Form Factor (SFF) Disk Storage Expansion Unit (MTM 2857-006) with 24 SFF slots for SAS SFF disk drives EXN3000: SAS Disk Storage Expansion Unit (MTM 2857-003) with 24 slots for SAS disk drives EXN1000: SATA Disk storage expansion unit (MTM 2861-001) with 14 low-profile slots for SATA disk drives Legacy support for expansion units |
| Disk drive storage shelf interface | PCI-x or PCI-e-based Fibre Channel-Arbitrated Loop (Fibre Channel-AL) |
| Environmental specifications | |
| Power supply/cooling fans | EXN3000: Dual (SATA) or Quad (SAS) redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) EXN1000, EXN3500, EXN4000: Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) |
| AC power/maximum current | 100 to 120 V ac/4.4 A; 200 to 240 V ac/2.3 A 100 to 120 V ac/7 A; 200 - 240 V ac/3.5 A; 50/60 Hz |
| Operating temperature maximum range | 10°C to 40°C (50°F to 104°F) |
| Recommended operating temperature range | 20°C to 25°C (68°F to 77°F) |
| Operating relative humidity range | 10% to 95% relative humidity, noncondensing 10% to 95% |
| Recommended operating relative humidity range | 40% to 55% noncondensing |
| Nonoperating temperature range | −40°C to 65°C (−40°F to 149°F) |
| Nonoperating relative humidity range | 10% to 95% relative humidity, noncondensing |
| Thermal rating | 1,215 Btu/hr (fully loaded disk storage expansion unit) |
| Operating acoustic noise | 56.4 dBA @ 1 m at 23°C, 5.64 bels @ 23°C |
| Dimensions (height/width/depth) | EXN4000 and EXN1000 3U EIA (5.25 in., 13.3 cm)/19 in. IEC rack-compliant (17.6 in., 44.7 cm)/20 in. (50.8 cm) EXN3000 4U EIA (6.9 in., 17.49 cm)/19 in. IEC rack-compliant (17.7 in., 44.87 cm)/25.7 in. (65.35 cm) |
| Weight | EXN4000: 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty EXN3000: 110 lbs (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty EXN1000: 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty |
| Regulations | |
| Disk shelf safety | UL/C-UL; CE |
| Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI |
| Immunity | EN 55024:1998 |
| Warranty | 3 years for hardware and licensed software, CRU and On-site service, Next Business Day 9x5, service upgrades available |
| N series Gateway supported backup methods | |
|---|---|
| Disk-based backup | SnapVault, SnapMirror |
| Host-based backup | NDMP/NFS/CIFS/iSCSI |
| Refer to the System Storage N series Gateway Interoperability Matrix at ibm.com/systems/storage/network (US) for more information on N series tape drive support. | |
| 3 | For use with the EXN3000/ EXN3500 and QSFP-QSFP cabling |