Power; POWER7; PowerHA SystemMirror | 
|

| 
| 
| 
| 
| 
|
| Abstract: IBM PowerHA SystemMirror for AIX adds Enterprise Edition Support for the IBM XIV Storage System (2810-A14/2812-114) |
IBM PowerHA SystemMirror for AIX adds Enterprise Edition Support for the IBM XIV Storage System (2810-A14/2812-114)
December 16, 2011
IBM PowerHA SystemMirror for AIX* extends Enterprise Edition support to the IBM XIV Storage
System (models 2810-A14/2812-114).
IBM PowerHA SystemMirror for AIX Enterprise Edition will now support High Availability and Disaster
Recovery (HA/DR) capability with synchronous and asynchronous replication for the IBM XIV.
Support is available for both direct FC-attach and NPIV through VIOS. It is not supported for attach
through VIOS/vSCSI.
Please refer to the following information for support details.
IBM XIV Storage System
(2810-A14/2812-114) | AIX V5.3 | AIX V6.1 | AIX V7.1 |
PowerHA SystemMirror V6.1 | PowerHA V6.1 SP7 (APAR IV11782),
AIX V5.3 TL9,
RSCT 2.4.13.0 | PowerHA V6.1 SP7 (APAR IV11782),
AIX V6.1 TL5 SP1,
RSCT 2.5.5.2 | PowerHA V6.1 SP7 (APAR IV11782),
AIX V7.1,
RSCT V3.1.0.3 |
Clients are advised to obtain the latest service updates for this support.
Notes:
- PowerHA requires XIV microcode level 10.2.4 or later for the 2810-A14 and XIV microcode
level 11.0.0 or later for the 2812-114
- When XIV is used in an EE cluster, both sites must use the same model of XIV. That is,
having both a 2810-A14 and a 2812-114 in the same cluster is not supported. IBM intends
to remove this restriction in a future release.
- Multipath I/O via iSCSI is not supported at this time. IBM intends to remove this restriction
in a future product update.
IBM Service can be obtained from the IBM Electronic Fix Distribution site at:
http://www.ibm.com/support/fixcentral/
PowerHA SystemMirror updates can be obtained from:
http://www14.software.ibm.com/webapp/set2/sas/f/hacmp/home.html
For questions or concerns, please send a note to HA Feedback at:
HA Solutions Feedback/Poughkeepsie/IBM or hafeedbk@us.ibm.com
* Trademark or registered trademark of International Business Machines Corporation.
Other company, product, and service names may be trademarks or service marks of others. |

Classification: | 
Hardware | 
Category: | 
Planning and Design |
 | 
| 
| 
|

Platform(s): | 
IBM Power Systems | 
| 
|

O/S: | 
AIX | 
Keywords: | 
powerha, xiv, hacmp, enterprise |
|
 |
| Is this your first visit to Techdocs (the Technical Sales Library)? |
 |
Learn more |
|
|
|