Skip to main content

 
IBM Systems  > Servers  > Mainframe servers  > Software Pricing  > 

Sub-Capacity Reporting Tool

For Reporting on System z Software License Requirements

  
Sub-Capacity Reporting Tool Recommended Maintenance
For optimal data collection and reporting, IBM recommends that you apply PTFs for the following APARs:
  • REQUIRED - must be installed prior to data collection
    WLM APAR OW55509 to allow WLM to calculate rolling 4-hour average utilization data and pass that calculation to a systems management tool, such as RMF, for all native z/OS LPARs. PTFs are available for z/OS Version 1, Releases 1 through 4.

  • BCP APAR OA20314 to allow customers who prefer not to change LPAR names to qualify for zNALC to use the "LICENSE=ZNALC" IPL parameter to indicate a zNALC LPAR

  • WLM APAR OA02710 to correct the MSU calculations for z890s, z990s and future machines

  • WLM APARs OW50998 and OW52306 to correct minor discrepancies between announced and calculated (SRM) machine capacity

  • WLM APARs OW49277, OW48894, and OW47277 to improve rolling 4-hour average and softcapping algorithms

  • SMF APAR OW50959 & DB2 APAR PQ51040 are used together to reduce the overhead involved in writing SMF89 records from DB2

  • SMF APAR OA11036 must be applied before the SMF type 89 records are collected with an LPAR date set to the future or the past

  • RMF APAR OA11375 must be applied before the SMF type 70 records are collected with an LPAR date set to the future or the past

  • Debug Tool APAR PK30452 (V5) or PK25531 (V6) corrects the SMF89 data reporting problem when Debug Tool product code executes as part of Debug Tool Utilities and Advanced Functions

  • IMS APAR PQ46529 corrects a data error when IMS cuts SMF89 records

  • WebSphere Application Server for z/OS V5 APARs PQ72892, PQ72893, PQ72894, and PQ67319 (corresponds with Service Level W500002) correct data error when WebSphere cuts SMF89 records

  • CMF - If you are using CMF to generate SMF70 records, contact BMC Support to ensure the correct CMF level/service.


The following APARs do not directly affect SCRT, but you might find them helpful:
  • RMF - APAR OW49536 - to correct minor inaccuracies in z/OS V1R1+ RMF Partition Data Report

  • RMF - APAR OW49807 - to add new RMF Monitor III function to monitor the current rolling 4-hour average (applies to z/OS V1R2+)

  • RMF - APAR OA07203 - to correct various Monitor 3 reporting problems


If you are running z/VSE in a sub-capacity environment there is no additional required service at this time.


If you are running z/TPF in a sub-capacity environment please be sure to check the z/TPF SCRT APAR page for any required service.


IBM always recommends that you install the most current microcode driver level available. The following microcode patches are available to fix specific problems which affect software pricing, but please be aware that more current microcode levels may be available. Please contact your IBM service representative to coordinate installation of any microcode.

  • Update the z990 software pricing MSUs; to allow z/OS WLM to measure rolling 4-hour average in terms of the new z990 software pricing MSUs.
    • Driver 52 - - MCL 058 in the EC Stream J12560
  • Correct occasional minor discrepancies between expected and reported capacity in configurations that include ICFs or IFLs.
    • Driver 38 - - MCL 067 in the EC Stream J10003
    • Driver 3C - - MCL 025 in the EC Stream J10637
    • Driver 3G - - fix included in 3G
  • Enhance the call home function of your zSeries server.
    • Driver 38 - - MCL 085 in the EC Stream J10005
    • Driver 3C - - MCL 097 in the EC Stream J10638
    • Driver 3G - - MCL 060 in the EC Stream J11213

 
More on SCRT Tool
SCRT User Guide
(Updated 10 Oct 2007)
 
dotted_rule_148.gif
SCRT Instructions
(Updated 10 Apr 2007)
 
dotted_rule_148.gif
Get Adobe® Reader®